Sharp XV-Z7000E Resetting the lamp timer, Replacing the Projection Lamp, Then Change Lamp Steps

Page 39

Replacing the Projection Lamp

Then Change Lamp (Steps 7-10)

7 Remove the lamp cage cover.

Turn over the projector and loosen the user service screw that secures the lamp cage cover. Then lift open the cover in the direction of the arrow.

8 Remove the lamp cage.

Loosen the securing screws on the lamp cage. Hold the lamp cage by the handle and pull it towards you.

&Troubleshooting

Maintenance

9 Insert the new lamp cage.

10 Attach the lamp cage cover.

Press the lamp cage firmly into the lamp cage

Slide the lamp cage cover in the direction of the

compartment. Fasten the securing screws.

arrow. Then tighten the user service screw.

Resetting the lamp timer

1 cord.Connect the power

2 Reset the lamp timer.

 

 

 

Plug the power cord into the AC

1 Press KEYSTONE and

“LAMP 0000H” is

socket of the projector.

KEYSTONE ƒ on the projector at

displayed, indicating that

 

 

 

 

 

 

 

 

 

the same time.

 

 

 

 

 

 

 

 

the lamp timer is reset.

 

 

 

 

 

 

 

 

 

2 Press INPUT and PICT MODE on

 

 

 

 

 

 

 

 

 

 

 

 

the projector at the same time.

 

 

 

 

 

 

 

 

 

 

 

 

3 Press PICT MODE and MENU on

 

 

 

 

 

 

 

 

 

 

 

 

the projector at the same time.

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

 

PICT MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

BACK

 

 

ENTER MENU

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset the lamp timer only after replacing the lamp.

39

Image 39 Contents
English Precautions a Observer Lors DU Important Safeguards Widescreen Images Outstanding FeaturesContents AUT I O N Temperature Monitor FunctionUsage Guidelines Lamp Monitor FunctionRCA Audio Input Lamp ReplacementPart Names ProjectorRGB/COMPONENT Remote ControlInserting the Batteries Part NamesAttaching the Rubber Leg Tips Positioning the Remote ControlSupplied Accessories Setup & ConnectionsProjector Connecting the ProjectorConnecting the Power Cord Connecting the Projector to Audiovisual EquipmentDTV decoder DTV decoder DVD playerPlug and Play function Connecting the Projector to a ComputerConnecting the Projector Connecting other compatible computersProjector Connecting RS-232C PortStartup image Maintenance indicatorsProjector Remote control Basic OperationsPress INPUT, Input 1, Input 2, S-VIDEO or 5INPUT 1 Mode Input 2 ModeVideo Mode Basic OperationsWide Mode Normal Mode Setting up the ScreenStandard Setup Front Projection Full ModeUsing the Adjustment Feet Reversed Image SetupCeiling-mount Setup GUI On-screen Display Using the Keystone buttonsUsing the GUI menu Digital Keystone CorrectionUsing the GUI Graphical User Interface Menu Screens Main menu Main menu Sub menuPAL Selecting the On-screen Display Language Picture Adjustments Adjusting the PictureDescription of Adjustment Items GUI On-screen Display Projector Remote Control Selecting the Signal TypeProgressive Mode Picture AdjustmentsOn-screen Display Auto Sync AdjustmentComputer Image Adjustments Input 2 RGB mode only Adjusting the Computer ImageFreeze Function Useful FeaturesDescription of Colour Temperature Adjusting the Colour TemperatureGamma Modes Gamma CorrectionSvga XGA Sxga Selecting the Picture Display ModeInput Signal Output screen image VGADescription of Automatic Power Shutoff Automatic Power Shutoff FunctionDescription of Theatre Modes Theatre Mode FunctionSelecting a Background Image Description of Background ImagesSpecial Mode Adjustment Reverse/Invert Image FunctionDescription of Projected Images Cleaning the air filter Air Filter MaintenanceRemove the filter cover Remove the air filter Lamp Lamp/Maintenance IndicatorsMaintenance Indicators Condition Problem Possible SolutionFirst Change Filter Steps Removing and installing the lamp unitCord.Disconnect the power Replacing the Projection LampReplacing the Projection Lamp Resetting the lamp timerPress Input and Pict Mode on Press Pict Mode and Menu onTroubleshooting Using the Kensington LockAttaching the Lens Cap AppendixGND Pin No Signal Name ReferenceConnection Pin Assignments Computer InputBasic format RS-232C Port SpecificationsPC control Communication conditionsWhen Bright of RGB Image Adjustment is set to 10 RS-232C Port Specifications CommandsComputer Compatibility Chart Specifications Units mm DimensionsGlossary
Related manuals
Manual 48 pages 8.85 Kb