Sharp AR-161, AR-160 specifications Off center adjustment SIM 50-13, SIM, OC mode in copying

Page 37

<Adjustment specification>

Mode

Specification

SIM

 

Set value

Set range

 

 

 

 

 

 

 

 

Main scanning

At normal:

SIM

 

Add 1:

1 ~ 99

direction

±1.0%

48-1

 

 

0.1% increase

 

magnification

 

 

 

 

Reduce 1:

 

ratio

 

 

 

 

0.1% decrease

 

 

 

 

 

 

 

 

 

Error in the auto correction mode

 

 

 

 

 

 

 

 

Display

 

Content

 

 

 

Major cause

 

 

 

 

 

 

Copy

 

The correction

 

Improper position of

quantity

 

value calculated is

 

reference width line of

display "– –"

 

over 5%.

 

 

 

the reference white plate

 

 

 

 

Improper installation of

 

 

 

 

 

 

CCD unit

 

 

 

 

 

 

 

 

Paper jam

 

Reference line

 

Defective CCD

 

lamp ON

 

scanning error

 

No reference white plate

(6)Sub scanning direction (scanning direction) magnification ratio adjustment (SIM 48-2, SIM 48-5)

a. OC mode in copying

Note: Before performing this adjustment, be sure to check that the CCD unit is properly installed.

1)Put a scale on the original table as shown below, and make a normal (100%) copy.

2)Compare the scale image and the actual image. If necessary, perform the following adjustment procedures.

3)Execute SIM 48-2.

4)After warmup, shading is performed and the current set value of the sub scanning direction magnification ratio is displayed on the display section in 2 digits.

5)Enter the set value and press the start key. The set value is stored and a copy is made.

<Adjustment specification>

Mode

Specification

SIM

Set value

Set range

 

 

 

 

 

Sub scanning

Normal

SIM

Add 1:

1 ~ 99

direction

±1.0%

48-2

0.1% increase

 

magnification

 

 

Reduce 1:

 

ratio

 

 

0.1% decrease

 

(OC mode)

 

 

 

 

 

 

 

 

 

b. SPF mode in copying

Note: Before performing this adjustment, be sure to check that the CCD unit is properly installed.

Before performing this adjustment, the OC mode adjust- ment in copying must be completed.

AR-161

1)Put a scale on the original table as shown below, and make a normal (100%) copy to make a test chart.

Note: Since the printed copy is used as a test chart, put the scale in parallel with the edge lines.

2)Set the test chart on the SPF and make a normal (100%) copy.

3)Compare the scale image and the actual image. If necessary, perform the following adjustment procedures.

4)Execute SIM 48-5.

5)After warmup, shading is performed and the current set value of the sub scanning direction magnification ratio is displayed on the display section in 2 digits.

6)Enter the set value and press the start key. The set value is stored and a copy is made.

<Adjustment specification>

Mode

Specification

SIM

Set value

Set range

 

 

 

 

 

Sub scanning

Normal

SIM

Add 1:

1 ~ 99

direction

±1.0%

48-5

0.1% increase

 

magnification

 

 

Reduce 1:

 

ratio

 

 

0.1% decrease

 

(SPF mode)

 

 

 

 

 

 

 

 

 

(7) Off center adjustment (SIM 50-13, SIM 50-16)

a. OC mode

Note: Before performing this adjustment, be sure to check that the paper off center is properly adjusted. (SIM 50-10)

1)Make a test chart as shown below and set it so that its center line is fit with the original guide center mark.

* To make a test chart, draw a line on A3 or 11" x 17" paper at the center in the paper transport direction.

2)Make a normal copy from the manual paper feed tray, and com- pare the copy and the test chart.

If necessary, perform the following adjustment procedures.

3)Execute SIM 50-13.

4)After warmup, shading is performed and the current set value of the off center adjustment is displayed on the display section in 2 digits.

5)Enter the set value and press the start key. The set value is stored and a copy is made.

7 – 7

Image 37
Contents AR-160 Class Laser Product Laser Klasse Contents General Specifications Copy magnification ratio Warmup timePrint density Print areaPower source Other specificationsPower consumption Machine compositionSupply system table Consumable PartsAsia, Southeast Asia Hong Kong / China Production number identification Environment conditionsConsumable parts recycling procedure Drum unit AR-161 Attach the main charger Appearance External Views and Internal StructuresInternal Operation Section Motor, solenoid, clutch Sensor, switch PWB unit 1 4 1 Cross sectional viewInstallation of machine Unpacking and InstallationInstallation of developing cartridge Installing conditionsRemoval and storage of fixing screw Changing the copy paper size in the tray Outline of operation Operational DescriptionsScanner section Basic structure of scanner section Process sectionBasic structure CCD PWBOutline of print process Operation cycleActual print process ChargingExposure CleaningTransfer Developing DC biasOptical discharge Semiconductor laser Laser unitPWB Laser beam path Paper feed sectionBrief descriptions of operations Cassette paper feed operationFusing section Adjustment item list AdjustmentsCopier adjustment Process sectionGrid bias voltage adjustment SIM 8-2, SIM Developing bias voltage adjustment SIMImage position adjustment SIM 50-1/SIM Mechanism sectionPaper off center adjustment AR-161 Main scanning direction FR direction distortion adjustment 10mm OC mode in copying Off center adjustment SIM 50-13, SIMOriginal sensor adjustment SIM Image density adjustmentCopy mode SIM SPFCancelling the simulation mode Entering the simulation modeSimulation List of simulationsContents of simulations Main Sub Contents Details of operation Initial Value Sheets Free 999999 sheets Mini maintenance counter When a is displayed Set value is stored Text LED AE LEDOC mode sub scanning Key operation User program functions User ProgramDepartment counter setting Setting change procedureDepartment number recording Function code Department counter setting/cancel Function codeDepartment number change Function code Department number delete Function codeFAX Trouble Code ListLSU CCDMaintenance table MaintenanceHigh voltage section Disassembly and AssemblyOptical section Copy lamp unit Fusing unit removalCopy lamp Lens unit Heater lamp Thermostat ThermistorPaper exit section Front cabinet unit, right cabinet disassemblyUpper heat roller Separation pawl Lower heat roller Paper exit unit Paper exit roller Transport roller MCU Optical frame unitLSU Intermittent frame unit Tray paper feed section/Paper transport sectionDrive unit Manual multi paper feed Manual multi paper feed sectionManual paper feed clutch Manual transport clutchPower unit Power sectionManual transport roller/Manual paper feed roller Multi feed solenoidWaste toner box Developing box MG roller Developing sectionDeveloping doctor MC holder unit Cleaning blade Electrical Section Block diagramOutline CPU HD6412351IF a. pin/signal table Block diagram MCUOUT POWIRQ6 Occover IRQ5 SpfcoverIRQ7 MHP IRQ3 SpfpaperReady OUT FaxpagePwoff OUT Scansp OUTImage Asic HG73C039FD Pin/signal tableOutline MDATA10 IN/OUT MDATA9 Fault OUTMDATA8 IN/OUT MDATA7 MDATA6 IN/OUTSWE0 OUT SOE0 OUTSCS0 OUT SAD0 OUTO Asic PWM0POUT Pfanmd GND POW VCC PMC4POUT3 DpxdbPWM1POUT Tfanmd P0OUT8 SophiaP1IN9 Faxready P1IN8 EsreadyTest PclreadyPMC3TCLK Lftclk OUT Rstb ResetPMC3DREQB OUT PMC4TCLK OUTMain motor drive circuit Reset circuitMirror motor circuit Toner supply motor drive circuit CCD PWBCircuit Diagram MCU MCU MCU MCU MCU MCU MCU MCU MCU Operation PWB1 Operation PWB2 Operation PWB3 Electronic Sort KEY PWB Actual Wiring Diagram Actual Wiring Diagram 2/3 Actual Wiring Diagram 3/3 AR-161 Copyright 1998 by Sharp Corporation

AR-160, AR-161 specifications

The Sharp AR-161 and AR-160 are monochrome multifunction printers that have made a mark in the office equipment landscape with their impressive features, technologies, and characteristics. Both devices are designed to cater to the needs of small to medium-sized businesses that require reliable, efficient, and compact systems for their printing, copying, and scanning needs.

One of the main features of the Sharp AR-161 and AR-160 is their impressive speed. The AR-161 can produce up to 16 pages per minute (ppm), while the AR-160 offers a slightly lower output at 15 ppm. This makes both models suitable for environments where quick document turnaround is essential. Additionally, both machines have a warm-up time of approximately 20 seconds, ensuring minimal downtime when starting up.

In terms of paper handling, both models come equipped with a 250-sheet paper drawer and a 100-sheet bypass tray, allowing for a variety of media types and sizes. The automatic document feeder (ADF) can accommodate up to 50 sheets, making it easier to handle multi-page documents without manual intervention. This feature enhances workflow efficiency significantly, particularly in busy office settings.

The Sharp AR-161 and AR-160 utilize advanced copying technologies, including a high-resolution scanning capability of up to 600 x 600 dpi. This means that documents are reproduced with clarity and detail, making them suitable for professional presentations and reports. The devices also offer various copying options, such as zoom, collation, and reduction/enlargement, providing versatility for different copying tasks.

Both models are equipped with Sharp's innovative ImageSEND technology, which allows users to scan documents directly to email, network folders, or USB drives with ease. This feature enhances productivity by streamlining the scanning process, ensuring that documents can be shared quickly and efficiently.

Furthermore, energy efficiency is a hallmark of the Sharp AR-161 and AR-160, as both models are ENERGY STAR qualified. This means they are designed to use less energy, helping businesses reduce their environmental impact while also saving on operational costs.

In conclusion, the Sharp AR-161 and AR-160 combine speed, versatility, and energy efficiency in a sleek design. Their advanced copying technologies and smart features make them ideal choices for businesses seeking reliable multifunction devices that can enhance productivity without compromising on quality.