Runco VX-55D Working With the Lamp, More information, refer to Lamp on, Filter Replacement on

Page 65

Access the Lamp Adjust menu to:

• Choose a lamp mode for regulating power and light output.

Note

You can also perform this task through the DHD Controller. For

more information, refer to Lamp on page 66.

3.13

Working With the Lamp

• Change the optical aperture size.

Note

You can also perform this task through the DHD Controller. For

more information, refer to RVR on page 68.

• View information pertaining to past and present lamps.

Note

You can also obtain this information through the DHD Controller.

For more information, refer to Lamp Info on page 72.

To access the Lamp Adjust menu, press MENU on the VX-44d/-55d built-in keypad (Figure 2-3). Then, Select Lamp Adjust from the Main Menu.

Lamp Hours (read-only):Lamp Hours shows the number of hours logged on the current lamp. Whenever you record a new lamp serial number, the VX-44d/-55d automatically resets this value to zero and begins to log time for the new lamp.

Lamp S/N (read-only):Lamp S/N is the serial number recorded for the current lamp. When you install a new lamp and enter its serial number, the number appears here.

Note

For detailed lamp replacement instructions, refer to Lamp and

Filter Replacement on page 77.

Lamp Message: Enter a check mark for Lamp Message to enable a warning message that appears upon power-up when the lamp has reached the specified lamp limit and should be replaced. Delete the check mark to prevent display of this message – instead, when your lamp expires, only the status display messages on the back of the projector will provide a visual warning to replace the lamp.

1. It is recommended that the Lamp Message check box remain

Note enabled.

2.When a lamp warning message appears, press EXIT to temporarily dismiss the warning. The message will continue to appear upon power-up until you install a new lamp.

Lamp Limit: Set Lamp Limit to the number of hours you expect to log on the current lamp before replacing it. This will trigger a lamp message on-screen (if enabled).

Lamp Adjust

 

Lamp Hours

147

 

Lamp S/N

123456789

1.

Lamp Message

 

2.

Lamp Limit

1000

3.

Lamp Mode

Power

4.

Power

500

5.

Intensity

0

6.

RVR

3

7.

Lamp History

 

8.

Change Lamp

 

Runco VX-44d/-55d Installation/Operation Manual

49

Image 65
Contents VX-44d VX-55d Page RuncoCare Standard Features RuncoCare Standard Two Year Limited WarrantyRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Page Table of Contents Install Projector Stand CineWide with AutoScope, Floor-Mount Specifications Maintenance and TroubleshootingOperation External ControlTable of Contents Xiv List of Figures Xvi About This Manual IntroductionCertain features Using This ManualSignificance. They also provide supplemental information Degrade performance or cause a malfunctionFormat screen Description, Features and BenefitsOptional Accessories VX-44d/-55d at a Glance Controls and FunctionsVX-44d/-55d Input Panel Input 1 Rgbhv RemoteEthernet VX-44d/-55d Built-In Keypad Left Button UP ButtonDown Button Right ButtonRunco Icon DHD Controller Front PanelIR Sensor Vacuum Fluorescent DisplayStandby LED Menu ButtonOutputs 1. Hdmi Out DHD Controller Rear PanelDisplay Control TriggersMain AC Fuse Main Power SwitchInputs DHD Controller/VX-44d/-55d Remote Control VX-44d/-55d Remote Control UnitEnter IR Output IndicatorReturn / Exit LightISF Night CinemaISF DAY CustRemote Control InstallationInstallation Overview Quick SetupInstallation must be performed by a qualified custom video Installation specialistProjector Installation Options Installation ConsiderationsInstallation Type Ambient LightVX-44d/-55d Lens Options and Throw Ratios Floor Installation Ceiling InstallationVertical and Horizontal PositionHorizontal Lens Shift Example only Vertical and Horizontal Lens Shift Limits Possible Audio Latency for Various Input/Output Timings Synchronization IssuesAudio/Video Input Timing Possible Audio Latency millisecondsOther Considerations Installing the Projection LensFixed CineWide Are both fully assembled Installing the Optional CineWide Lens MountAutoScope or Base Plate AutoScope stand used for floor-mounted projector VX-44d/-55d MountingVX-44d/VX-55d Input Panel Connections to VX-44d/-55d and DHD ControllerComponents to the DHD Connecting SourceSections that follow Controller10. Hdmi Source Connections DTV-Set-Top Box BD/DVD DTV-STB12. Rgbhv Source Connections Computer RGB CamcorderGaming Console VCRDVD/DTV STB Camcorder Composite and S-Video Source ConnectionsConnection RS-232 ControllerAutoScope Lens Motor Connecting 12-volt Trigger Outputs to External EquipmentReceiver to the DHD Connecting an External IRInput voltage to the AutoScope lens motor must be between Connecting to AC PowerHdmi Turning on the PowerAdjusting the Picture Orientation Primary Lens AdjustmentsOn the VX-44d/-55d built-in keypad see -3, press Menu Focus and Zoom Vertical and Horizontal Lens ShiftAssembly to Lens Motor Installing and Adjusting the CineWide Anamorphic LensCarriage Plate CineWide With AutoScope or BaseHorizontal Position X Adjustment Installation Geometry Anamorphic Lens Top ViewAre disabled Installation Lamp AdjustOptimizing Lamp and Lens Performance Navigating the Projector MenusLumaCal lamp calibration takes approximately two minutes To using LumaCalInstallation Menu Above, the Automatic Lens Calibration setting has no effect Power cyclesWorking With the Lamp Filter Replacement onMore information, refer to Lamp on More information, refer to RVR onIntensity value is not the actual lumen output, but rather a Originally expected may no longer be possibleMore easily maintained as the lamp ages Installation Operation Using the On-Screen MenusRunco Video ServiceMain Menu Aspect Ratio Input SourceInput Source Aspect RatioRemote Aspect Ratio Control Description Key 169 Aspect Ratio SettingsSelect 169 to view 169 DVDs Hdtv programs in theirOverscan Remote Aspect Ratio Control Description KeyPicture PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Input Position ResolutionInput Position Adjust the Phase after adjusting Tracking see below Memory Presets Memory PresetsCalibration You must enter a passcode to access the Calibration menuInformation Operation Color Temperature Preset Associated x/y Values Color Temperature Presets and Associated Color PointsDisplay Color Auto Color Enable Test Pattern Enable Description SettingCopy/Paste Copied settings are not retained after a power cycleYou must enter a passcode to access the Service menu ServiceService Should be used by ISF-certified technicians onlyInput Names Absolutely necessary, as it may cause artifacts in the image Operation Operation Operation 64 and ISF Day/Night Memory Presets Lamp Replacement Maintenance and TroubleshootingLamp and Filter Replacement Removing the Lamp Lens Replacement Removing the Primary Lens Symptom Possible Causes Solution Troubleshooting TipsTroubleshooting Chart Configure Lens Motor Error Codes VX-44d/-55d Error CodesCode Description General Lamp FailuresBuilt-In Keypad Code Description Power and CoolingTipm Image Processor Miscellaneous Code Description Panel Driver and FormatterMaintenance and Troubleshooting Serial Command Syntax Port ConfigurationExternal Control Serial CommunicationsAspect Ratio Commands Serial CommandsInput Selection Commands Image Preset Commands Output Shift Commands Exit Return key Enter keyWith Toggle Bit = Hex Binary Function Start Using Discrete IR CodesCommand Bits Remote Control With Toggle Description Button Name Bit = IR Command ListRC5 Control Codes for the DHD Controller RC5 DataEnter VX-44d/-55d Specifications SpecificationsVX-44d/-55d Specifications Industry-Standard Specifications Theater Calibration SpecificationsPower Requirements VX-44d DimensionsDHD Controller Specifications DHD Controller SpecificationsVX-44d/-55d Dimensions VX-44d/-55d DimensionsFormat Resolution Frequency Rate Hz MHz KHz Supported Signal Timings by InputSupported Timings Supported? √ = Yes, = NoPAL-B/G/H/I 101 102 Page 020-0826-02 Rev. B April
Related manuals
Manual 114 pages 2.55 Kb

VX-55D, VX-44D specifications

The Runco VX-55D and VX-44D projectors represent a pinnacle in home theater technology, offering expansive image quality and immersive viewing experiences. Runco, known for its commitment to delivering exceptional visual performance, has integrated numerous features and advanced technologies in these models.

One of the standout features of both the VX-55D and VX-44D is their native 1080p resolution, delivering stunningly sharp images with vibrant colors that capture the finest details. This high definition capability ensures that viewers can enjoy their favorite movies, sports, and gaming content with unparalleled clarity. The projectors utilize the latest DLP (Digital Light Processing) technology, which enhances brightness and color accuracy, providing a more vivid and lifelike picture.

Another impressive characteristic of the Runco VX series is its exceptional contrast ratios. With deep blacks and brilliant whites, these projectors offer a dynamic range that brings out subtle details in both shadow and highlight areas. This contrast performance is particularly beneficial for watching films in darker environments, where the depth of imagery is crucial for immersion.

In terms of color processing, the VX-55D and VX-44D incorporate Runco's proprietary ColorPalette technology. This system ensures accurate and rich color reproduction by utilizing a wide color gamut, allowing viewers to experience content as the creators intended. Coupled with advanced color management capabilities, users can further tweak their viewing experience to match their preferences.

The integration of flexible installation options is another highlight of these projectors. They support up to 10-point digital keystone correction, making setup simple and adaptable to various room configurations. This flexibility ensures that no matter the space, users can achieve a perfectly aligned and geometrically accurate image.

Runco has also designed the VX-55D and VX-44D with user-friendly interfaces, including intuitive remote controls and on-screen menus. Both projectors come equipped with multiple HDMI inputs, allowing users to connect various devices seamlessly. Additionally, they support 3D content playback, a feature that has become increasingly important for enhancing the cinematic experience.

Energy efficiency is a consideration in the design of these projectors as well, making them not only high-performance devices but also more sustainable than many of their counterparts. With a sleek aesthetic, the Runco VX-55D and VX-44D can seamlessly blend into any home theater setup, adding a touch of elegance while providing an extraordinary viewing experience.

In summary, the Runco VX-55D and VX-44D projectors are characterized by their high-definition resolution, advanced DLP technology, rich color processing, and flexible installation options, making them ideal choices for any home theater enthusiast looking to elevate their viewing experience.