Runco CL-610LT manual Reset Lamp Timer Fan Control Return to User OSD

Page 42

On-Screen Display Menus

Reset Lamp Timer

Fan Control

Return to User OSD

use different IR codes. Or, you can use a single remote and change the IR code as needed to address a specific projector.

When you change the secondary IR code, the remote sends that code instead of the primary IR code.

NOTE: The Remote Control menu is read-only and need not be visible in order to change the secondary IR code.

To simultaneously change the secondary IR code and synchronize that remote with a projector, point the remote at the projector, then press and hold ◄ and ► simultaneously for five seconds. The Remote Control edit window, shown at right, appears. Type a new, two-digit code.

The procedure for changing the secondary IR code on the remote only is the same, except that you point the remote away from the projector.

When you replace the projector lamp, you should also reset the lamp timer. To do this, select Reset Lamp Timer from the Set Up menu. Press the right-arrow key on the remote to highlight “Yes,” then press Enter to confirm the reset.

NOTE: Reset the Lamp Timer ONLY after you replace the lamp. Otherwise, the reported “Lamp Hours” will be inaccurate.

WARNING! Do not exceed the recommended lamp life of 2000 hours. An old lamp becomes increasingly fragile and prone to sudden failure.

Select Fan Control from the Set Up Menu to control the operation of the projector’s cooling fan.

Mode: In most cases, the default Fan Control Mode (Auto Normal) will maintain the correct operating temperature. If the lamp frequently turns off due to overheating, or in certain high-altitude operating environments, you may need to change this setting to Auto Hi. Altitude or Manual.

Fan Speed: If you set the Fan Mode to Manual, select Fan Speed and use the on-screen slidebar to adjust the speed.

After changing either of these settings, press Exit to return to the previous menu.

To exit the Set Up menu, use the up- or down-arrow keys to highlight Return to User OSD and press Enter.

To return to the Set Up menu, select it from the Main Menu, press Enter twice, then press MENU on the remote control. (You do not need to re-enter the passcode.)

Remote Control

Secondary +20

Reset Lamp Timer Reset only if you replace lamp

Are you sure?

No Yes

Fan Control Mode

Fan Speed

Fan Control

>Auto Normal Auto Hi. Altitude Manual

Fan Speed

 

+2 -

+

42

Runco CL-610 Owner’s Operating Manual

Image 42
Contents CL-610 and CL-610LT Page Table of Contents Table of Contents TWO Year Limited Warranty RIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Overview Overview Cable Opening Rear / Bottom View Connector PanelAC Power in Socket AC Power Switch Cable Access Door Lamp Module CoverThis page is intentionally left blank Controls and Functions Control PanelConnector Panel Runco Logo Remote Control OFFPIP+ Installation Installation Considerations Screen Type and Size Front Screen InstallationsRear screen installations Screen sizeOther Considerations Throw Distance Ceiling Installation Floor InstallationMounting Folded Optics Connecting Video Inputs ConnectionsConnections Connecting a Computer Gbrhv Connecting an Hdmi Device Hdmi Source DVD player or HD tuner with Hdmi or DVI outConnecting to AC Power Adjusting Projector Height or Projection Angle Turning on the PowerAdjusting the Zoom and Focus Basic OperationAdjusting the Picture Selecting Video MemorySelecting an Aspect Ratio Setting the Menu Selecting the Input SourcePIP / PBP Function Turning off the Power Using the Menu On-Screen Display MenusMain Menu Picture Quality Adjustments Runco CL-610Kelvins Custom Aspect Ratio Standard 4 xVirtual Cinema Language Picture Orientation Source ONLY, press the arrow key to highlight Yes then To restore the default image settings for the current inputOption Press EnterPC & HD Adjust Setup Gamma Selection Amplitude Adjust menu allows you to fine-tune the image Reset Lamp Timer Fan Control Return to User OSD Aspect Ratio Installation Option Setup Ntsc Lamp Replacement Contact Your Runco Dealer Lamp Replacement Projector Remote controlRed Power LED Does not turn onTroubleshooting RS-232 Setup Connecting RS-232 to the ProjectorRS-232 Pin Assignments Sub 9-pin female Pin RJ-11 Function RS-232C Control Codes Code FunctionRS-232C Control Codes This page is intentionally left blank Specifications CL-610CL-610LT Home Theater Calibration Specifications Industry-Standard SpecificationsDimensions RUMA-011115