Runco CL-610LT manual Lamp Replacement Contact Your Runco Dealer

Page 45

Lamp Replacement (Contact Your Runco Dealer)

The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or sooner if a noticeable degradation in brightness occurs.

1.Turn off the projector and unplug the power cord. Allow the projector to cool down for approximately 45 minutes prior to removing the lamp assembly for replacement.

2.Remove the two screws from the lamp cover.

3.Remove the lamp cover.

4. Remove the two screws from the lamp module.

5.Pull the lamp module straight out to remove it.

6.Insert the new lamp module securely and replace the two screws.

7.Replace the lamp cover at the right side first as shown and secure it with the two screws.

8.Turn on the power and go into the Setup/Reset Lamp Timer menu to reset the lamp timer. Refer to “Set Up” in the previous section, On-Screen Display Menus.

Runco CL-610 Owner’s Operating Manual

45

Image 45
Contents CL-610 and CL-610LT Page Table of Contents Table of Contents TWO Year Limited Warranty RIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Overview Overview AC Power in Socket AC Power Switch Cable Access Door Rear / Bottom View Connector PanelCable Opening Lamp Module CoverThis page is intentionally left blank Control Panel Controls and FunctionsConnector Panel Runco Logo OFF Remote ControlPIP+ Installation Screen Type and Size Front Screen Installations Installation ConsiderationsScreen size Rear screen installationsOther Considerations Throw Distance Floor Installation Ceiling InstallationMounting Folded Optics Connections Connecting Video InputsConnections Hdmi Source DVD player or HD tuner with Hdmi or DVI out Connecting a Computer Gbrhv Connecting an Hdmi DeviceConnecting to AC Power Adjusting the Zoom and Focus Turning on the PowerAdjusting Projector Height or Projection Angle Basic OperationAdjusting the Picture Selecting Video MemorySelecting an Aspect Ratio Setting the Menu Selecting the Input SourcePIP / PBP Function Turning off the Power Using the Menu On-Screen Display MenusMain Menu Runco CL-610 Picture Quality AdjustmentsKelvins Custom Standard 4 x Aspect RatioVirtual Cinema Language Picture Orientation Option To restore the default image settings for the current inputSource ONLY, press the arrow key to highlight Yes then Press EnterPC & HD Adjust Setup Gamma Selection Amplitude Adjust menu allows you to fine-tune the image Reset Lamp Timer Fan Control Return to User OSD Aspect Ratio Installation Option Setup Ntsc Lamp Replacement Contact Your Runco Dealer Lamp Replacement Red Power LED Remote controlProjector Does not turn onTroubleshooting RS-232 Setup Connecting RS-232 to the ProjectorRS-232 Pin Assignments Sub 9-pin female Pin RJ-11 Function Code Function RS-232C Control CodesRS-232C Control Codes This page is intentionally left blank Specifications CL-610CL-610LT Industry-Standard Specifications Home Theater Calibration SpecificationsDimensions RUMA-011115