Alcatel-Lucent 1850 TSS-320 Protection, Gmpls control plane, Management, Physical specifications

Page 3

Protection

Ethernet network protection

¬RSTP: 802.1w

¬MSTP: 802.1s

¬Link aggregation

T-MPLS network protection

¬Tunnel Linear Protection 1:1

SONET/SDH network protection

¬Single- and dual-ended APS 1 + 1

¬Subnetwork Connection Protocol (SNCP), unidirectional path- switched ring (UPSR)

¬Multiplex Section-Protection Ring

(MSPRING) 2F bidirectional line switching ring (BLSR)

Equipment protection

¬Power protection

¬Controller protection

¬Universal switch protection

GMPLS control plane

T-MPLS tunnel setup

TDM HO path setup

Management

Alcatel-Lucent 1350 Optical

Management System (OMS)

TL1

Zero-installation craft (ZIC) terminal

Simple Network Management

Protocol (SNMP)

Command line interface (CLI)

Secure Shell (SSH) v2/Secure Socket

Layer (SSL) for secure connection

Physical specifications

ANSI

Dimensions: 1850 TSS-320 subrack

Subrack dimensions

¬Height: 624 mm (24.6 in.)

¬Width: 532 mm (20.9 in.)

¬Depth: 304.8 mm (12.0 in.)/

355.6mm (14.0 in.)

Designed to be installed in a standard ANSI rack

¬Height: 2.13 m (7 ft)

¬Width: 660.4 mm (26.0 in.)

¬Depth: 304.8 mm (12.0 in.)/

355.6mm (14.0 in.)

Power and cooling

Power supply: DC feed (-48 V DC nominal)

Power supply: -58 V

Power consumption: up to 3500 W

Cooling: forced air

Environmental

Operating temperature:

-5°C to +45°C (23°F to 113°F)

Relative humidity:

0% to 90%, non-condensed

Regulatory compliance

CE and UL certification

NEBS level 3

FCC part 15 class A

ETSI

Dimensions: 1850 TSS-320 subrack

Subrack dimensions

¬Height: 624 mm (24.6 in.)

¬Width: 532 mm (20.9 in.)

¬Depth: 288 mm (11.3 in.)

Designed to be installed in a standard ETSI rack

¬Height: 2.20 m (86.6 in.)

¬Width: 600 mm (23.6 in.)

¬Depth: 300 mm (11.8 in.)

Power and cooling

Power supply: DC feed

(-48 V DC nominal)

Power supply: -65 V

Power consumption: up to 3500 W

Cooling: forced air

Environment

Operating temperature:

-5°C to +45°C (23°F to 113°F)

Relative humidity: 0% to 90%, non-condensed

Regulatory compliance

CE certification

Operating conditions:

ETS 300 019, Class 3.2

Storage conditions:

ETS 300 019, Class 1.2

Transportation conditions:

ETS 300 019, Class 2.2

Electrostatic discharge (ESD)/ electromagnetic compatibility

(EMC): ETS 300 386 “Telecommuni- cations Center”

Alcatel-Lucent 1850 TSS-320 Release 3 Data Sheet

3

Image 3
Contents Alcatel-Lucent 1850 TSS-320 FeaturesBenefits Technical specificationsManagement Physical specificationsProtection Gmpls control planeCAR4688080813