Please check the following before calling for service:

Place one cup of water in a glass measuring cup in the oven and close the door securely. Operate the oven for one minute at HIGH 100%.

A Does the oven light come on?

YES _______ NO _______

B Does the cooling fan work?

YES _______ NO _______

(Put your hand over the bottom ventilation openings.)

 

C Does the turntable rotate?

YES _______ NO _______

(It is normal for the turntable to turn in either direction.)

 

D Is the water in the oven warm?

YES _______ NO _______

If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker. If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER. A microwave oven should never be serviced by a “do-it-yourself” repair person.

NOTE: If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 25 and cancel.

S P E C I F I C A T I O N S

 

R-1210, R-1211, R-1214

AC Line Voltage:

Single phase 120V, 60Hz, AC only

AC Power Required:

1530 watts, 13.0 amps.

Output Power:*

1100 watts

Frequency:

2450 MHz

Outside Dimensions:

23 7/8"(W) x 14 1/16"(H) x 15 9/16"(D)

Cavity Dimensions:

17 1/2"(W) x 9 7/8"(H) x 14 15/16"(D)

Oven Capacity:**

1.5 Cu. Ft.

Cooking Uniformity:

Turntable system, diameter 14 1/8"

Weight:

Approx. 55 lb

 

 

The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method is widely recognized.

★★Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.

In compliance with standards set by:

FCC

– Federal Communications Commission Authorized.

DHHS

Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I,

 

 

Subchapter J.

 

This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.