Calibration

Calibration

The PCS and PCS2 work by setting a threshold. The STANDBY threshold is set be-tween the current draw of the OFF state and that of the STANDBY state. The ON threshold is then set between the current draw of the STANDBY state and the ON state.

The PCS2 contains two major circuits, each independent of each other. Each if these major circuits contain two sub-circuits, the ON and STANDBY circuits. The following paragraphs will address the sub-circuits for each major circuit of the PCS2.

PCS

The state status for the PCS is:

!STANDBY senses when the current is at or below standby threshold. The LED lights and relay switch output is closed when below ON.

!ON senses when current is at or above ON threshold. The LED lights and relay switch output is closed when above ON.

!The circuit (both the ON and STANDBY) can differentiate between 20 mA and 1 A. Anything above 1 A is sensed as 1 A, regardless if it is 2 A, 6 A, or 10 A.

PCS2

The PCS2 has an inline 10 A fuse for protection. This will allow one, or both major circuits to draw a maximum of 10 A (1,200 W) total.

The state status for each of the major circuits of the PCS2 is:

!STANDBY is lit when the sensed current level is above STANDBY threshold.

!STANDBY remains lit (regardless of its setting) when the ON LED lights.

!ON is lit when current is above the ON threshold.

!The circuit (both the ON and STANDBY) can differentiate between 20 mA and 1 A. Anything above 1 A is sensed as 1 A, regardless if it is 2 A, 6 A, or 10 A.

!It is not logical for ON to light before STANDBY. As a result, the circuit is de-signed so that if the ON is lit, the STANDBY will also be lit, regardless of its setting.

When extreme accuracy is required for calibration, it is best to plug the PCS or PCS2 into a wall outlet at least 15 minutes before calibration to allow the circuitry to warm up. Calibration of the PCS and PCS2 must be accomplished prior to use. Calibration of the PCS and PCS2 is accomplished as follows:

PCS Calibration

In the PCS, the ON state is dependent of the STANDBY mode but the STANDBY mode is not dependent on the ON mode. They work together to provide a final level, where the Standby power level provides a base and the ON level is an increment to that level. FIG. 7 illustrates the relationship that the STANDBY and ON power levels have with each other in determining the final power level.

PCS and PCS2 Power Current Sensors

7

 

 

 

 

Image 11
Contents PCS and PCS2 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Product Information SpecificationsProduct Information Rack mounting the PCS2 InstallationPCS and PCS2 Installation Wiring GuidelinesPCS to AXC-INP8 Preparing captive wiresPCS2 to Axcent, Axcent2, or Axcent3 PCS2 to AXC-INP8PCS to Axcent, Axcent2, or Axcent3 PCS2 to Television Controllers PCS to Television ControllersPCS Calibration CalibrationStandby and On level relationship PCS2 Calibration Calibration Programming Operation and ProgrammingPCS Operation PCS2 OperationPCS2 Programming Operation and Programming PCS and PCS2 Power Current Sensors AMX reserves