AMX PCS2 instruction manual Preparing captive wires, PCS to AXC-INP8

Page 8

Installation

Do not connect power to the PCS/PCS2 until the wiring is complete.

Preparing captive wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.

Never pre-tin wires for compression-type connections.

1.Strip 0.25 inch (6.35 mm) of insulation off all wires.

2.Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section.

3.Turn the flat-head screws clockwise to secure the wire in the connector. Do not over-torque the screws; doing so can bend the seating pin and damage the connector.

PCS to AXC-INP8

Connect the PCS output ports to the AXC-INP8 input ports as shown in FIG. 1; follow the illustration for input 1 through input 8. Set the jumpers of the associated inputs on the AXC-INP8 (refer to the AXC-INP8 Switch/Opto Voltage Input Card instruction manual) to Switch mode. All Switch mode inputs and the CardFrame share common GND.

AXC-INP8

GND

INP1

GND

STBY

PCS

GND

INP2

CardFrame GND (-)12 VDC or

external + power

supply

FIG. 1 PCS to AXC-INP8

ON

PWR

If using a power supply that is independent of the CardFrame, an optional GND wire is necessary.

 

4

PCS and PCS2 Power Current Sensors

 

 

 

Image 8
Contents PCS and PCS2 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Specifications Product InformationProduct Information Installation PCS and PCS2 InstallationWiring Guidelines Rack mounting the PCS2Preparing captive wires PCS to AXC-INP8PCS2 to Axcent, Axcent2, or Axcent3 PCS2 to AXC-INP8PCS to Axcent, Axcent2, or Axcent3 PCS to Television Controllers PCS2 to Television ControllersCalibration PCS CalibrationStandby and On level relationship PCS2 Calibration Calibration Operation and Programming PCS OperationPCS2 Operation ProgrammingPCS2 Programming Operation and Programming PCS and PCS2 Power Current Sensors AMX reserves