Agilent Technologies U2121A-101 manual Connect the hardware solution to your PC

Page 24

3Disconnect any instrument that is connected to your PC and close all other applications on your PC.

4Double- click the saved installation file to begin installation.

5If you do not have any of the prerequisites installed, the InstallShield Wizard software prerequisite will appear.

6Click OK to begin the installation of the listed missing prerequisites.

7Once the above installation has completed, installation of the Agilent U21210A- BAsed RF Switch Driver Software will proceed as normal.

8Follow the instructions on your screen to begin the installation.

9Click Finish once the installation has completed.

C.Connect the hardware solution to your PC

1Connect the U2121A- 101 board digital IO terminal to the U2121A terminal block using the interface cable.

2Connect the power adapter to the RF switch driver board’s DC power jack.

3Connect the RF switches as below:

iFor 8762/3/4 and 8765x- 324 RF switches, connect to any SL1[1] to SL5[1] slot.

iiFor 8765x- 024 RF switches, connect to any X1[2] to X5[2] slot.

iiiFor N181x RF switches, connect to any SV1[3] to SV5[3] slot.

N O TE

Connect only one type of the RF switch to one channel. Do not use multiple switches simultaneously on one channel.

4Connect other types of load to general IO, X7[4] or X8[5] and X9[6] if required. The load voltage is 24 VDC. The maximum load should not exceed 300 mA per output channel and 3 mA per input channel.

14

U2121A-101 Operating Guide

Image 24 Contents
Operating Guide U T I O N WA RN I N G Safety Symbols Supply ground and/or circuit board ground BoardEnvironmental Conditions Regulatory Markings Product Category Affixed product label is shown as belowFor more information Viii Regulatory Information for Australia/New Zealand U2121A-101 Operating Guide Contents Introduction Operating timePower supply Power consumptionStandard Purchase Items Checklist Product at a Glance Product outlookTop view without casing Product dimensions Top view with casingFront view with casing 85.00 mm 153.00 mmConnector Pins Configuration Pin out configuration for all terminals8762/2/3 and 8765x-324 Series switches X1 to 8765x-024 Series switches SL1 to SL5Output enable/disable control IO mappingPosition information read back control IO mapping for 8765x-024 Series RF switches Position indicator stage definitionRF Switches Model Activated Deactivated State BInstallation Guide With Agilent VEE Pro, LabVIEW, or Microsoft Visual StudioCheck your system Hardware requirementsSoftware requirements Install prerequisites and software Installing the application software from CDInstallation and operation processes Downloading the application software from the Web Connect the hardware solution to your PC Launch the Agilent U2121A-Based RF Switch Driver Software Consumption is not more than 1500 mAIO Control will launch automatically when you start your PC Your PCU2121A-101 Operating Guide Information Supported Switches Output enable Drive ChA Drive active Drive ChBDrive modes Continuous DrivePulse drive General IOControlled supply Output From U2121A do Input To U2121A DI Product Characteristics and Specifications General CharacteristicsAgilent Microwave Spdt Switches Maintenance Disassemble Procedure U2121A-101 Operating Guide Optional accessory RF switch driver board ordering optionsRF switch driver board optional accessory Ordering InfoAppendix a Control Instructions To read digital input informationMinimum System Requirements Monitored when supplying continuous current To set digital outputMore information Appendix B Y1157A Cable Assembly Instructions Strain relief Pin 1 of ribbon cable Contact us
Related manuals
Manual 41 pages 53.7 Kb