SMARTNET/SMARTZONE FEATURES

List Entry Method

1.With a SMARTNET/SmartZone channel selected, momentarily press

the Phone option switch. The phone mode is indicated by the icon, and the display indicates the alias of the last called telephone number if it is in your phone number list. Otherwise, the last called telephone number is displayed.

2.Enter the index of the desired telephone number if you know it or scroll through the list using the and keys until you find the desired number. Press the CLR key to cancel the call.

3.Press the PTT switch or the ENT key to initiate the call. The display indicates “WAIT” while the connection to the phone system is occur- ring. Once connected, the normal dial tone is heard and the alias of the number being called is displayed. The radio then automatically dials the telephone number and the normal ringing or busy tone is heard.

Proceed to the bulleted list which follows the next method for condi- tions that may then occur.

Direct Entry Method (Full Keypad Models Only)

1.With a SMARTNET/SmartZone channel selected, press and hold the Phone option switch until a tone sounds (approximately 1 second). The last phone number called is displayed, and the phone mode is indicated

by the icon.

2.Enter the number using the 0-9and # keys. To dial a * character, press F1 and then the * key. To enter a pause (indicated by “P”), press the F1, * , and then # keys. The number scrolls to the left in the display so that the seven right-most digits are always displayed. Numbers up to 16 digits (including pauses) can be entered. Press the CLR key to cancel the call.

3.Press the PTT switch or the ENT key to initiate the call. The display indicates “WAIT” while the connection to the phone system is occur- ring. Once connected, the normal dial tone is heard and the alias of the number being called is displayed. The radio then automatically dials the

42

Image 42
Contents Series Page Page Safety Information Other Important Operating Information Conventional Features FeaturesGeneral Features Smartnet II FeaturesTable of Contents Intrinsically Safe Classification Option Switch Functions Conventional ModeSMARTNET/SMARTZONE Mode Top Panel Indicators Controls and DisplayTop Panel Controls Side Controls Front Panel Keys 3-Key Model Front Panel Keys 15-Key Model Display Turning Power On and Setting Volume General OperationIntroduction Option Switches BacklightChannel and Zone Selection Low Battery IndicationKeypad Lock Channel SelectTime-Out Timer Zone SelectHome Zone Tone Enable/Disable ScanningIntroduction Standard Scanning Radio Wide ScanningScan Resume Delay Standard Mode Scan ListRadio Wide Mode Scan List Determining Which Channels are in Scan List Nuisance Channel DeleteConventional and SMARTNET/SmartZone Operation Conventional Operation SMARTNET/SmartZone OperationConventional Features Display Mode SelectionMonitoring Before Transmitting Monitor Mode Busy Channel Lockout Call Guard SquelchPenalty Timer Conversation Timer Power Output SelectRepeater Talk-Around Conventional Mode Scanning GeneralSelecting a Scan List Transmitting in Scan Mode Programming a Scan ListPriority Channel Sampling Changing The Priority ChannelStandard Conventional Calls SMARTNET/SMARTZONE Features DTMF/ANI SignalingViewing Unit ID Standard Group Calls Enhanced Private Conversation Calls Placing an Enhanced Private Conversation CallSMARTNET/SMARTZONE Features Receiving an Enhanced Private Conversation Call Private Conversation II Calls Placing a Private Conversation II CallSMARTNET/SMARTZONE Features Receiving a Private Conversation II Call Telephone CallsPlacing a Telephone Call SMARTNET/SMARTZONE Features SMARTNET/SMARTZONE Features Call Alert Messaging Sending Status Conditions Emergency Alarm and Emergency Call Failsoft OperationSMARTNET/SmartZone Scanning Dynamic RegroupingDetermining Current Site and Searching For New Site Miscellaneous Locking/Unlocking a SiteSupervisory Tones Miscellaneous Rechargeable Battery Pack Miscellaneous Operation At Extended Range Dealer ProgrammingSpeaking Into Microphone LicensingTransceiver Service Intrinsically Safe ClassificationClassification of Hazardous Areas Division Classification of Atmospheres Class/GroupIndex Typical Hazard Group ClassSmartnet 6 Index

FM Portable Radio Intrinsically-Safe SMARTNET, SmartZone Conventional, 7700 Series specifications

The EFJohnson 7700 Series FM Portable Radio is designed for the most demanding environments, especially in industries that prioritize safety and communication reliability. This cutting-edge equipment meets the stringent requirements for intrinsically safe operations, making it an optimal choice for first responders, industrial applications, and hazardous environments.

One of the main features of the EFJohnson 7700 Series is its adherence to the high standards of intrinsically safe certifications. This ensures that the radio can operate safely in potentially explosive atmospheres without igniting flammable gases or dust. Additionally, the 7700 series is designed to withstand harsh conditions, including extreme temperatures, moisture, and physical impact, ensuring that users can rely on it even in the toughest scenarios.

The radio supports SMARTNET and SmartZone Conventional technologies, enhancing its versatility. SMARTNET is a trunked radio system that allows for efficient use of communication channels, accommodating multiple users within a single frequency band. This is particularly beneficial for large agencies that require seamless and coordinated communication across various teams. SmartZone Conventional provides flexible interoperability, making it easy for users to communicate with different radio systems and networks.

With advanced signal processing technology, the EFJohnson 7700 series offers superior audio clarity, minimizing background noise and ensuring that messages are transmitted and received with precision. The user-friendly interface features large buttons and a bright display, allowing for easy operation even while wearing gloves or during low-light conditions. Furthermore, the radio includes programmable function keys, enabling users to customize their experience based on specific operational needs.

The EFJohnson 7700 Series is equipped with robust battery technology, providing extended operational time and ensuring that users remain connected during critical missions. The lightweight design enhances portability, making it easy to carry during long shifts. Durability features include water and dust resistance, meeting IP67 standards to ensure reliability in outdoor terrain.

In conclusion, the EFJohnson 7700 Series FM Portable Radio combines advanced technologies, safety features, and user-focused design, making it an essential tool for professionals in hazardous environments. With its commitment to reliability and efficiency, the 7700 Series stands out as a leading choice for teams that require the best in communications technology.