Allied Telesis AT-X510-28GSX, AT-X510-52GTX, AT-X510-28GTX 10/100/1000Base-T Twisted Pair Ports

Page 23

x510 Series Installation Guide for Stand-alone Switches

10/100/1000Base-T Twisted Pair Ports

Speed

Duplex Mode

Wiring Configuration

The switches have 24 or 48 10/100/1000Base-T ports.

The ports can operate at 10, 100, or 1000 Mbps. The speeds may be set manually using the management software or automatically with Auto- Negotiation (IEEE 802.3u), the default setting.

Note

The ports must be set to Auto-Negotiation to function at 1000 Mbps and are not compatible with devices that are not IEEE 802.3u compliant.

The twisted pair ports can operate in either half- or full-duplex mode. The duplex mode of a port, like port speed, may be set manually using the management software or automatically with Auto-Negotiation (IEEE 802.3u), the default setting.

The speed and duplex mode settings of a port may be set independently of each other. For example, a port may be configured such that its speed is set manually while its duplex mode is established through Auto- Negotiation.

Note

A switch port should not use Auto-Negotiation to set its duplex mode if it is connected to a network device that does not support Auto- Negotiation for 10 or 100 Mbps operation and has a fixed duplex mode of full-duplex. Otherwise, a duplex-mode mismatch may occur in which a switch port and a network device operate at different duplex modes. The duplex modes of switch ports that are connected to network devices that do not support Auto-Negotiation should be set manually through the management software.

The wiring configuration of a port operating at 10 or 100 Mbps can be MDI or MDI-X. The wiring configurations of a switch port and a network device connected with straight-through twisted pair cabling have to be opposite, such that one device is using MDI and the other MDI-X. For instance, a switch port has to be set to MDI-X if it is connected to a network device set to MDI.

You may set the wiring configurations of the ports manually or let the switch configure them automatically with auto-MDI/MDI-X (IEEE 802.3ab- compliant). This feature enables the switch to automatically negotiate with network devices to establish their proper settings.

23

Image 23
Contents Installation Guide for Stand-alone Switches Copyright 2013 Allied Telesis, Inc Electrical Safety and Emissions Standards Translated Safety Statements Contents Page Figures Figures Tables Tables Preface Document Conventions Contacting Allied Telesis Preface Chapter OverviewSFP Slots FeaturesX510 Models 10/100/1000 Mbps Twisted Pair Ports X510 Series Installation Guide for Stand-alone Switches Overview Front and Back Panels Front panels of the x510 Series switches are shownAT-x510-28GSX 10/100/1000Base-T and 100/1000Base-FX Back Panel of the AT-x510-28GPX and AT-x510-52GPX X510 Series Management Panel Management Panel10/100/1000Base-T Twisted Pair Ports Speed Duplex Mode Wiring ConfigurationCable Type 10Mbps 100Mbps 1000Mbps Distance Cable Requirements Port PinoutsPoE Standards Power Over EthernetMaximum Power Class Output from a Switch PD Power Range 1000Mbps Cable Type Non PoE PoE+ Port Prioritization Wiring Implementation SFP+ Slots Transceiver Model Cable Type Distance Stacking SFP+ SlotsEco-friendly Button LEDs for the Twisted Pair Ports LEDsLED PoE LEDs for the SFP Slots LEDs for the SFP+ Slots Switch ID LED Switch ID LED Switch ID LEDs in the Low Power Mode USB Port Console Port Power Supplies Overview Beginning the Installation Reviewing Safety Precautions X510 Series Installation Guide for Stand-alone Switches Beginning the Installation X510 Series Installation Guide for Stand-alone Switches Choosing a Site for the Switch Unpacking the Switch Beginning the Installation Installing the Switch on a Table or in an Equipment Rack Installing the Switch on a Table or Desktop Removing the Rubber Feet Installing the Switch in an Equipment RackAttaching the Equipment Rack Brackets X510 Series Installation Guide for Stand-alone Switches Installing the Switch on a Table or in an Equipment Rack Cabling the Networking Ports Cabling the Twisted Pair Ports X510 Series Installation Guide for Stand-alone Switches Installing SFP and SFP+ Transceivers Installing SFP Modules in the AT-x510-28GSX Switch Cabling the Networking Ports SFP Handle Installing SFP SFP+ Modules Removing the Dust Cover from an SFP or SFP+ Transceiver SFP Handle Powering On the Switch Powering On the Switch Monitoring Initialization Processes Switch Initialization MessagesSwitch Initialization Messages X510 Series Installation Guide for Stand-alone Switches Starting a Local Management Session Configuring the Switch for Stand-alone OperationsX510 Series Installation Guide for Stand-alone Switches Disabling VCStack No stack id enable Show interface port1.0.51 Confirming Status VCStack FeatureStatus of a Stacking Slot When VCStack is Enabled Port1.0.n Troubleshooting Troubleshooting X510 Series Installation Guide for Stand-alone Switches Troubleshooting Appendix a Technical SpecificationsPhysical Specifications Power Specifications Environmental SpecificationsRJ-45 Twisted Pair Port Pinouts CertificationsRX+ TX+ RJ-45 Style Serial Console Port PinoutsTransmit Data Ground Receive Data Looped to pin Appendix a Technical Specifications

AT-X510-28GPX, AT-X510-28GSX, AT-X510-52GPX, AT-X510-28GTX, AT-X510-52GTX specifications

Allied Telesis has made significant strides in network infrastructure solutions with its AT-X510 series of managed Ethernet switches. The series includes models such as the AT-X510-28GTX, AT-X510-28GPX, AT-X510-52GTX, AT-X510-28GSX, and AT-X510-52GPX. These switches combine performance, flexibility, and ease of management to meet the demands of various networking environments.

One of the standout features of the AT-X510 series is its robust performance capabilities. These switches are equipped with advanced Layer 2 switching functionalities that support a range of protocols and enhance overall network efficiency. With high forwarding capacities, they ensure that data is transmitted quickly, making them ideal for bandwidth-intensive applications such as video conferencing and cloud services.

Another significant advantage of the AT-X510 series is Power over Ethernet (PoE) support, particularly in the GPX and GSX models. This feature allows the switches to deliver power to connected devices like IP cameras, Wi-Fi access points, and VoIP phones without requiring separate power supplies. This consolidates cabling, simplifies installation, and enhances flexibility in device placement.

The AT-X510 switches also incorporate advanced security functionalities like IEEE 802.1X port-based access control, which ensures that only authorized devices can connect to the network. This is particularly critical in environments where data security is a top priority. Additionally, the switches support VLANs (Virtual Local Area Networks), which help isolate network traffic, enhance performance, and provide an additional layer of security.

Management and configuration of the AT-X510 series are streamlined through an intuitive web-based interface and support for SNMP (Simple Network Management Protocol). This simplifies monitoring and troubleshooting, allowing administrators to manage the network efficiently without extensive training.

The hardware design of the AT-X510 series is also worth noting. Built with reliability in mind, these switches come with redundant power supply options, ensuring continued operation during power failures. The fanless design in some models also contributes to quieter operation, making them suitable for office environments.

Overall, the Allied Telesis AT-X510 series, including the AT-X510-28GTX, AT-X510-28GPX, AT-X510-52GTX, AT-X510-28GSX, and AT-X510-52GPX, offers a compelling combination of performance, flexibility, and security. These switches cater to the needs of modern networks, allowing businesses to build efficient, secure, and well-managed network infrastructures.