Allied Telesis SB251-10 manual Availability

Page 13
Availability

Patch SB251-10 For SwitchBlade 4000 Series Switches and AT-9800 Series Switches

13

PCR: 02587

Module: OSPF

Network affecting: No

When OSPF was enabled on startup, an OSPF interface would sometimes stay in the DOWN state. This issue has been resolved.

PCR: 03001

Module: SWI CLASSIFIER

Network affecting: No

The following parameters have been changed CREATE CLASSIFIER, SET

CLASSIFIER and SHOW CLASSIFIER commands:

The MACTYPE parameter has been changed to MACTYPE={L2UCASTL2MCASTL2BCASTANY}. This resolves an error with internal hardware tables.

The number of user-specified protocols in the PROTOCOL parameter has been increased from three to seven.

The minimum value of the IPXDADDRESS parameter has been decreased from 10000000 to 00000001.

PCR: 03006

Module: SWI

Network affecting: No

An issue which sometimes resulted in a broadcast storm within the internal ports on the SwitchBlade, a reduction in bandwidth, and a loss of pinging has been resolved.

PCR: 3008

Module: SWI

Network affecting: No

An issue which caused pings to fail when a control card was inserted in the left hand slot to act as a slave, has been resolved.

PCR: 03014

Module: IPG, SWI

Network affecting: No

Support has been added to allow for multicasting to any number of overlapping VLANs up to the maximum number of multicast forwarding entries.

PCR: 03018

Module: SWI

Network affecting: No

An issue with pings failing after network host routes disappeared from the switch due to an IP hashing error has been resolved.

PCR: 03020

Module: SWI

Network affecting: No

An issue with an interrupt occurring when waiting on the MDIO which caused the MDIO to read or write incorrect information has been resolved.

PCR: 03021

Module: SWI

Network affecting: No

Ping would sometimes not work correctly after a 48 line card was extracted, and after a restart reboot. This issue has been resolved.

Availability

Patches can be downloaded from the Software Updates area of the Allied Telesyn web site at www.alliedtelesyn.co.nz/support/updates/patches.html. A licence or password is not required to use a patch.

Patch SB251-10 for Software Release 2.5.1 C613-10361-00 REV J

Image 13
Contents Patch SB251-10 For SwitchBlade 4000 Series Switches and IntroductionAT-9800 Series Switches Patch Release NoteFeatures in SB251-10 Features in SB251-09 Features in SB251-08 Module STP, SWI Features in SB251-07Features in SB251-05 Features in SB251-06Module SWI, SYSR sb-251.rez Features in SB251-0424 -Mar-2003 sb251-04.pazFeatures in SB251-03 This means that port counters can now be shown Features in SB251-02 The DPORT parameter in the ADD SWITCH HWFILTER command was omitted when the configuration was generated. This issue has been resolved Features in SB251-01 Availability Patch SB251-10 for Software Release 2.5.1 C613-10361-00 REV J Patch Release Note