Base Software Release File

sb-251.rez

 

 

Patch Release Date

14-May-2003

 

 

Compressed Patch File Name

sb251-08.paz

 

 

Compressed Patch File Size

86524 bytes

 

 

Patch SB251-08 includes all issues resolved and enhancements released in previous patches for Software Release 2.5.1, and the following enhancements:

PCR: 03251

Module: SWI

Level: 2

A fatal error occurred when the ADD SWITCH TRUNK command specified an invalid port. This issue has been resolved.

PCR: 03414

Module: SWI

Level: 2

A fatal error occurred when removing a line card from a SwitchBlade if STP was enabled. This issue has been resolved.

PCR: 03466

Module: SWI

Level: 2

System performance was low when adding large numbers of entries to CAM. This issue has been resolved. CAM is now initialised to allow better performance, especially for the addition of ARP and IP entries.

PCR: 03470

Module: SWI

Level: 2

The DELETE SWITCH TRUNK PORT command could cause an unrelated port to stop forwarding packets, or learn new MAC addresses. This issue has been resolved so that unrelated ports are not affected by the trunk group port deletion.

PCR: 03509

Module: SWI

Level: 2

All IP routes were being added to all switch instances. This caused issues on SwitchBlade line cards that did not have enough CAM to store the routes, and the line card did not always need every route. IP routes are now only added:

to a switch instance if the route was learned on that instance

if the route is for an interface

if the route was added statically, or

if the switch instance has a CAM which is the same size or larger than the CAM of the switch instance that the route was learned on.

PCR: 03518

Module: SWI

Level: 3

An issue exists where the CAM entry 0 in the VLAN Tag table is either not updated or is being overwritten with invalid data. This PCR adds debugging to trace the fault.

Patch SB251-10 for Software Release 2.5.1 C613-10361-00 REV J

Image 4
Contents Introduction Patch SB251-10 For SwitchBlade 4000 Series Switches andAT-9800 Series Switches Patch Release NoteFeatures in SB251-10 Features in SB251-09 Features in SB251-08 Features in SB251-07 Module STP, SWIFeatures in SB251-05 Features in SB251-06Module SWI, SYSR Features in SB251-04 sb-251.rez24 -Mar-2003 sb251-04.pazFeatures in SB251-03 This means that port counters can now be shown Features in SB251-02 The DPORT parameter in the ADD SWITCH HWFILTER command was omitted when the configuration was generated. This issue has been resolved Features in SB251-01 Availability Patch Release Note Patch SB251-10 for Software Release 2.5.1 C613-10361-00 REV J