Accton Technology FAST ETHERHUB-12S manual Precise Guidelines for Configuring Multiple Hubs

Page 23

Fast EtherHub-12s User’s Guide

Precise Guidelines for Configuring Multiple Hubs

A detailed formula for calculating maximum cable length was provided in the section on Precise Cable Length Budgeting in Chapter 2. This formula stated that the maximum length of cabling that can be run from end-node to end-node is:

367m S(repeater equivalent length) + S(length of CAT-5 twisted-pair cable)

For the daisy chain of three hubs shown in Figure 3-3, communications must be supported for node pairs AB and AC. In this case, first determine the limitations on cable length found on the longest path (i.e., the path with the longest delay time).

Remember that this Class II device has an inherent repeater delay of 90 bit time or 80 meters of twisted-pair cable. Therefore, if node A and B are linked to repeaters 1 and 3 respectively (each using 50 meters of twisted-pair cable), then the maximum length from node A to B is 367m - (3 x 80m) = 127m and the total inter-hub cabling will be limited to 27 meters (i.e., 127m - 2x50m = 27m). Therefore, if you use 15 meters of twisted-pair cable to connect hubs 1 and 2, then 12 meters of cable can be used to connect hubs 2 and 3.

Then, if node A and C are linked to adjacent repeaters 1 and 2 in this system, the maximum length of twisted-pair cable that can be used to connect node C to hub 2 is 367m - 2*80m - 50m - 15m = 142 meters. However, the maximum length for any twisted-pair connection cannot exceed 100 meters.

Configuring the Network

3-3

Image 23
Contents Fast EtherHub-12s Installation Manual QWHUQDWLRQDO+HDGTXDUWHUV Package Contents Quick Installation Fast EtherHub-12s User’s Guide About this Guide Contents Appendix B Port and Cable Assignments Appendix a TroubleshootingAppendix C Specifications Appendix E Product Support ServicesList of Tables Glossary Index List of FiguresAccton’s Fast EtherHub-12s Product OverviewIntroduction to Fast Ethernet Basic Features Fast EtherHub-12s User’s Guide Pre-Installation Requirements Installing the SystemMaking a Connection via an MDI-X Station Port Connecting the Hub SystemDistance Limit for Fast Ethernet Cabling Making a Connection via the MDI Daisy-Chain PortPrecise Cable Length Budgeting Providing Power to the EtherHub Verifying System Operation Verifying Port StatusFast EtherHub-12s User’s Guide Stand-Alone Configuring the NetworkConnecting Multiple Hubs Multiple Hub Configuration Using the Daisy-Chain Port Using the RJ-45 Daisy-Chain PortPrecise Guidelines for Configuring Multiple Hubs Cabling Limits for Multiple Hub Configuration Front Panel IndicatorsHardware Reference Color Red Label Alert Function Fan status Hardware Reference Color Label Function RJ-45 Ethernet Ports Rear Panel Power SocketDiagnosing Hub Indicators Appendix a TroubleshootingInstallation System DiagnosticsPower and Cooling Problems Hub Integrity Physical ConfigurationRJ-45 Port Appendix BCategory 5 STP/UTP Appendix C Product SpecificationsFCC Class B Certification Appendix DEMI Certification Voluntary Control Council for Interference VCCI-2 European Community Immunity Requirements CE Mark Declaration of Conformance for EMI and SafetyUnderwriters Laboratories Inc Safety ComplianceSicherheitshinweise Product Registration Appendix E Product Support ServicesProblem Report Hardware Repair ServiceInteractive Fast Fax U.S.A. office Bulletin Board Service BBSInternational Headquarters USA Headquarters Technical SupportCustomer Remedies Limited WarrantyNorth and South America Return ProcessOrdering Information Accton Offices100BASE-TX GlossaryLED Shielded Twisted-Pair STP Index Index EH3012-TX 150114-101 E0197-R02