Advantech 4718 user manual Device Testing, Testing Analog Input Function

Page 24

Table 2.1: Gain Code

Gain Code (Hex)

Type

Range

 

 

 

0x08

Voltage

0-15mV

 

 

 

0x0A

Voltage

0-50mV

 

 

 

0x0B

Voltage

0-100mV

 

 

 

0x0D

Voltage

0-500mV

 

 

 

0x0E

Voltage

0-1.0V

 

 

 

0x0F

Voltage

0-2.5V

 

 

 

0x8000

Current

0-20mA

 

 

 

0x8001

Current

4-20mA

 

 

 

2.5 Device Testing

Following the Setup and Configuration procedures to the last step described in the previous section, you can now proceed to test the device by clicking the Test Button in the I/O Device Installation dialog window. In the Device Test dialog window, you are free to test various functions of USB-4718 on the Analog input, Analog output, Digital input, Digital out- put or Counter tabs.

2.5.1 Testing Analog Input Function

Click the Analog Input tab to bring it up to front of the screen. Select the input range for each channel in the Input range drop-down boxes. Config- ure the sampling rate on the scroll bar. Switch the channels by using the up/down arrow.

USB-4718 User Manual

18

Image 24
Contents USB-4718 Channel Thermocouple Input ModuleCopyright Acknowledgements Product Warranty 2 years Safety Precaution Static Electricity Technical Support and AssistanceDocument Feedback Contents Appendix Function Block Appendix C Firmware Download Utility Introduction Features ApplicationsInstallation Guide Installation Flow Chart Software Overview Programming Choices for DA&C ModuleDevice Drivers Device Driver Programming Roadmap Programming Tools\Program Files\Advantech\ADSAPI\Examples Troubleshooting Device Drivers Error Programming with Device Drivers Function LibraryPage Installation Unpacking After taking out the module, you should firstDriver Installation CD-ROMHardware Installation Driver InstallationDevice Manager Screen Device Setup & Configuration USB-4718 Device SpeedSetting Up the Device Configuring the DeviceDevice Setting Dialog Box Gain Code Setting Device Testing Testing Analog Input FunctionTesting Analog Output Function Analog Input Tab/Device Test DialogTesting Digital Input Function Testing Digital Output FunctionRed lamp High Green lamp Low Hardware Uninstallation Testing Counter Function11 Unplug or Eject Hardware Dialog Signal Connections I/O Connectors OverviewPin Assignment I/O Connector Pin Assignment 2 I/O Connector Signal Description LED Indicator Status Description4 3.2.4 Jumper Setting Description JP1~JP8 Input Mode Setting for Analog Input ChannelsJP13 Watchdog Timer Setting How to Reset USB-4718 ManuallyAnalog Input Connections Isolated Digital Input ConnectionsIsolated Digital Output Connections Digital Input Channel ConnectionsField Wiring Considerations Isolated Digital Input Channel ConnectionsPage Specifications Analog Input Accuracy for ThermocoupleIsolated Digital Input Isolated Digital OutputGeneral Table A.5 GeneralFunction Block Appendix B Function Block Firmware Download Utility Appendix C Firmware Download Utility Figure C.2 USB Download Utility Figure C.4 Firmware Download Completed Analog Input Calibration Appendix D Analog Input Calibration Voltage Input CalibrationFigure D.1 USB-4718 Device Setting window Figure D.2 USB-4718 Calibration Wizard Figure D.4 Full range calibration Figure D.6 Select the current input range setting Current Input Calibration