Advantech 4718 user manual Features, Applications

Page 8

Chapter 1 Introduction

USB-4718 offers 8 thermocouple inputs with 16-bit resolution, up to 0.1% input range accuracy, or 4~20 mA inputs. Reliable and rugged enough for industrial applications, yet inexpensive enough for home projects, USB-4718 is the perfect way to add measurement and control capability to any USB capable computer. The USB-4718 is fully USB plug and play and easy to use. It obtains all required power from the USB port, so no external power connection is ever required.

1.1 Features

USB-4718 has the most requested measurement & control functions:

8 differential thermocouple input channels

16 bits resolution

Software configurable for thermocouple, low level voltage or current inputs.

Wiring burned-out detectable function (Thermo mode)

2,500 Vdc isolation

Watchdog Timer

Supports 0~20 & 4~20mA current inputs.

Bus-powered

Device status LED indicator

Removable on-module wiring terminal

USB 2.0 Support

Hot swappable

Note: For detailed specifications of USB-4718, please refer to Appendix A, Specifications.

1.2Applications

Temperature measurement

Industrial ON/OFF control

Industrial and Lab. automation

USB-4718 User Manual

2

Image 8
Contents USB-4718 Channel Thermocouple Input ModuleCopyright Acknowledgements Product Warranty 2 years Document Feedback Safety Precaution Static ElectricityTechnical Support and Assistance Contents Appendix Function Block Appendix C Firmware Download Utility Introduction Features ApplicationsInstallation Guide Installation Flow Chart Device Drivers Software OverviewProgramming Choices for DA&C Module \Program Files\Advantech\ADSAPI\Examples Device Driver Programming RoadmapProgramming Tools Troubleshooting Device Drivers Error Programming with Device Drivers Function LibraryPage Installation Unpacking After taking out the module, you should firstDriver Installation CD-ROMHardware Installation Driver InstallationDevice Manager Screen Device Setup & Configuration USB-4718 Device SpeedSetting Up the Device Configuring the DeviceDevice Setting Dialog Box Gain Code Setting Device Testing Testing Analog Input FunctionTesting Analog Output Function Analog Input Tab/Device Test DialogRed lamp High Green lamp Low Testing Digital Input FunctionTesting Digital Output Function Hardware Uninstallation Testing Counter Function11 Unplug or Eject Hardware Dialog Signal Connections Pin Assignment I/O ConnectorsOverview I/O Connector Pin Assignment 2 I/O Connector Signal Description LED Indicator Status Description4 3.2.4 Jumper Setting Description JP1~JP8 Input Mode Setting for Analog Input ChannelsJP13 Watchdog Timer Setting How to Reset USB-4718 ManuallyAnalog Input Connections Isolated Digital Input ConnectionsIsolated Digital Output Connections Digital Input Channel ConnectionsField Wiring Considerations Isolated Digital Input Channel ConnectionsPage Specifications Analog Input Accuracy for ThermocoupleIsolated Digital Input Isolated Digital OutputGeneral Table A.5 GeneralFunction Block Appendix B Function Block Firmware Download Utility Appendix C Firmware Download Utility Figure C.2 USB Download Utility Figure C.4 Firmware Download Completed Analog Input Calibration Appendix D Analog Input Calibration Voltage Input CalibrationFigure D.1 USB-4718 Device Setting window Figure D.2 USB-4718 Calibration Wizard Figure D.4 Full range calibration Figure D.6 Select the current input range setting Current Input Calibration