Accton Technology E0398-R01, 150858-101, EH1502S manual Optional Management Software

Page 9

EtherHub 1500 System

DB9 Serial Port to RJ-45 Converter Connector Pin Assignment

Description

RJ-45 Pin

EH1502S

Mapping

DB9

 

DTR (Data Terminal Ready)

1

4

RxD (Received Data)

2

2

TxD (Transmitted Data)

3

3

SG (Signal Ground)

4

5

RI (Ring Indicator)

5

9

CTS (Clear-to-Send)

6

8

RTS (Request-to-Send)

7

7

DCD (Data Carrier Detected)

8

1

DSR (Data Set Ready)

NC

6

DB9 PC's COM Port to RJ-45 Converter Connector Pin Assignment

Description

RJ-45 Pin

EH1502

Mapping

DB9

 

DTR (Data Terminal Ready)

1

6

RxD (Received Data)

2

3

TxD (Transmitted Data)

3

2

SG (Signal Ground)

4

5

RI (Ring Indicator)

5

9

CTS (Clear-to-Send)

6

7

RTS (Request-to-Send)

7

8

DCD (Data Carrier Detected)

8

1

DSR (Data Set Ready)

NC

4

DB25 RS232 to RJ-45 Converter Connector Pin Assignment

Description

RJ-45 Pin

EH1502S

Mapping

DB25

 

DTR (Data Terminal Ready)

1

20

RxD (Received Data)

2

3

TxD (Transmitted Data)

3

2

SG (Signal Ground)

4

7

RI (Ring Indicator)

5

22

CTS (Clear-to-Send)

6

5

RTS (Request-to-Send)

7

4

DCD (Data Carrier Detected)

8

8

DSR (Data Set Ready)

NC

6

Connection from Hub's 9-Pin Serial Port to PC's 9-Pin COM Port

 

Hub's 9-Pin

 

CCITT Signal

PC's 9-Pin

 

Serial Port

 

COM Port

 

 

 

 

1 DCD

---

---- DCD --------

1

2

RXD

<-

---- TXD ---------

3

3

TXD

---

---- RXD ------

>

2

4

DTR

---

---- DSR ------

>

6

5

SGND

---

---- SGND ------

5

6

DSR

---

---- DTR --------

4

7

RTS

---

---- CTS ------

>

8

8

CTS

<-

----- RTS --------

7

9

RI

---

---- RI -----------

9

Advanced Reference Guide

Connection from Hub's 9-Pin Serial Port to Modem's 25-Pin DCE Port

Hub's 9-Pin

 

CCITT Signal

Modem's 25-Pin

Serial Port

 

COM Port

 

 

 

1

<--

---- DCD -------

8

2

<--

---- RXD -------

3

3

---

----- TXD ------

>

2

4

---

----- DTR ------

>

20

5

---

----- SGND -----

7

6

<--

---- DSR -------

6

7

---

----- RTS ------

>

4

8

<--

---- CTS -------

5

9

<--

---- RI -------

 

22

Connection from Hub's 9-Pin Serial Port to PC's 25-Pin DTE Port

 

Hub's 9-Pin Serial Port

Null Modem

PC's 25-Pin DTE Port

1 DCD

1

1

8

DCD

2

RXD

2

3

3

TXD

3

TXD

3

2

2

RXD

4

DTR

4

8

20

DTR

5

SGND

5

20

7

SGND

6

DSR

6

7

6

DSR

7

RTS

7

4

4

RTS

8

CTS

9

5

5

CTS

9

RI

20

6

22

RI

Optional Management Software

SW6120: AccView EtherHub Manager for SunNet Manager

SW6121: AccView EtherHub Manager for OpenView/Windows

SW6122: AccView EtherHub Manager for OpenView/Unix

SW6122: AccView EtherHub Manager for NMS

SW6130: Network Mangement Support Modules for NMM

SW7300: EtherHub 1500 Security Module

12

13

Image 9
Contents EtherHub-16mi+ Advanced Reference Guide Internet support@accton.com.tw EtherHub-16mi+Contents Using Configuration Program Configures Communities, IP and IPX trap managersIsolates/attaches a hub, or sets the hubs segment Reset Configuration Restores the last saved configuration Save ConfigurationDefault Gateway Disable IPX protocol by setting this number to zeroThis table Snmp Community NamesStatus IP Trap ManagersAllignment Errors Backup SetCRC Errors Total ErrorsTroubleshooting Optional Management Software