Accton Technology E0398-R01 Snmp Community Names, This table, Status, IP Trap Managers, System

Page 6

EtherHub 1500 System

Field

Description

 

 

SNMP Community Names

The community strings authorized for trap management access. All

 

community strings used for IP and IPX Trap Managers must be listed in

 

this table.

 

 

Community Name

A community entry authorized for trap management access.

 

 

Access

Management access is restricted to read-only (RO) or read/write (RW).

 

 

Status

The status of the current entry can be set to VALID or INVALID.

 

 

IP Trap Managers

IP management stations selected to receive trap messages from the

 

system.

 

 

IP Address

IP address of the management station.

 

 

Community Name

The community string required for trap management access.

 

 

Status

The status of the current entry can be set to VALID or INVALID.

 

 

IPX Trap Managers

IPX management stations selected to receive trap messages from the

 

system.

 

 

Net Number

Identifies the IPX network number for the connected slot.

 

 

Node ID

MAC address of the authorized trap manager.

Community Name

The community string required for trap management access.

 

 

Status

The status of the current entry can be set to VALID or INVALID.

Downloading System Software - Use the Download command from the System Menu to load available software updates into the agent's flash ROM. The download file should be an EtherHub binary file from Accton Technology Corporation; otherwise the agent will not accept it.

Invoking this command brings up the Download dialog box. When all entries are confirmed, the display will change to show the progress of the download process. After downloading the new software, the agent will automatically restart itself. The following describes each entry in the dialog box:

Field

Description

 

 

Timeout

Time to wait for a response.

 

 

Retry

Number of attempts to make contact.

 

 

Filename

The binary file to download.

 

 

Transferred Block

Current number of data block being transferred.

 

 

Total Blocks

Total number of blocks to transfer.

Restarting the Agent - Use the Restart command from the System menu to reset a selected agent. LEDs on the agent will light up sequentially as it executes the initialization test.

Reverting Configuration to Factory Settings - Use the Factory Settings command from the System menu to change all configuration settings back to the factory defaults.

Save Configuration - Saves configuration settings made during current session. Reset Configuration - Restores configuration settings saved the last time.

Advanced Reference Guide

Control Menu

Menu

Description

 

 

Hub

Includes hub description and commands to isolate/reattach network

 

connection, or assign hub to a specified segment.

 

 

Port

Includes port description and command to enable/disable selected port.

 

 

Backup Port

Defines master/slave port pairs used for emergency backup.

 

 

Push Button

Enables/disables external Configure button on selected hub.

Configuring Hub Parameters - Use the Hub command from the Control menu to configure any hub in the stack. (Select the required hub using the <F4> and <F5> function keys.) This menu provides a brief description of the selected hub, and also allows you to isolate/reattach the hub from the network.

Field

Description

 

 

Hub ID

Hub identifier within the stack. (Up to 10 hubs may be connected via

 

the management channel.) Note that hub IDs can only be assigned

 

using the Configure button as described in the Quick Installation Guide.

 

 

Position

The physical position in the stack.

 

 

Name

Any user-defined name for the selected hub.

 

 

Status

The stack connection may be set to ISOLATED or ATTACHED. Note

 

that the Isolated LED will be lit if the hub is isolated. (Although the

 

status of OTHER is provided, this is for internal use only.)

Segment

Attach the hub to a specified segment. The appropriate Segment icon

 

will light up to show that the hub has been connected.

 

 

Type

Indicates hub type as EH1501S, or EH1502S (Master or Slave).

Firmware Ver.

Indicates the current firmware version number.

6

7

Image 6
Contents EtherHub-16mi+ Advanced Reference Guide EtherHub-16mi+ Internet support@accton.com.twContents Using Configuration Program Configures Communities, IP and IPX trap managersIsolates/attaches a hub, or sets the hubs segment Default Gateway Save ConfigurationReset Configuration Restores the last saved configuration Disable IPX protocol by setting this number to zeroStatus Snmp Community NamesThis table IP Trap ManagersCRC Errors Backup SetAllignment Errors Total ErrorsTroubleshooting Optional Management Software