Accton Technology 150858-101, E0398-R01, EH1502S manual Using Configuration Program

Page 4

EtherHub 1500 System

Note: The on-board program only provides access to basic configuration functions. To access the full range of SNMP mangement functions, you must use SNMP-based network mangement software. Accton provides Windows-based SNMP software called AccView/Open with this package. Note that AccView/Open’s Hub Manager module can be easily integrated into most third-party management platforms.

Starting the Configuration Program

Insert the distribution diskette provided with your EtherHub-16mi+into the PC's floppy drive.Then activate the EtherHub 1500 System Configuration Program as described below.

Note: 1. When using a PCMCIA modem connection, add the following entry to your config.sys file: “device=cardtalk.sys /A /Com3IRQ=4”. If your PC has a PCMCIA modem or multi-I/O card, set the proper IRQ by typing "EH15SCP/i [irq #]".

2.Help is available by entering "EH15SCP/?".

3.This program can only run under DOS, or in Windows DOS shell.

1.Type "EH15SCP" at the DOS prompt C:\>EH15SCP. Using arrow keys, select the communication port on the workstation that is connected to the hub.

2.Select the appropriate option from the DCE/DTE dialog box:

Terminal Channel for local hookup, or Modem Channel for remote connection.

Advanced Reference Guide

3.If setting up a remote connection via modems:

Select Modem Channel to open the Phone List menu as shown below, and enter the phone number and press [Enter] to start the dialing mechanism.

Once the connection is established, the main menu for out-of-band configuration appears as shown below.

Using Configuration Program

The EtherHub 1500 System Configuration Program allows you to define system parameters, manage and control stacked hubs and associated ports, set threshold levels, and monitor network conditions. The following table briefly describes the menu selections available for this program.

Menu

 

Description

System

Information -

Defines description for the system.

 

Configuration -

Sets system parameters.

 

Trap Managers -

Configures Communities, IP and IPX trap managers.

 

Download -

Downloads new version of firmware to update your system.

 

Restart -

Restarts your system.

 

Factory Setting -

Reverts all configuration selections to factory default settings.

 

Save Configuration -

Saves the configuration changes made during the current session.

 

Reset Configuration - Restore the last saved configuration.

Control

Hub -

Isolates/attaches a hub, or sets the hub's segment..

 

Port -

Disables/enables a port..

 

Backup port -

Sets up to 3 pairs of backup ports. Each pair contains a master

 

 

and slave port. The slave port is normally disabled. When the

 

 

master port fails, the system disables the master port and enables

 

 

the slave port to maintain the link.

 

Push button -

Enables/disables Configure button to prevent unauthorized use.

Performance

Provides 4 sub-menus - System, Segment, Hub and Port. This selection allows you to

 

view network performance for the selected component. Performance is measured in

 

terms of frames received, number of bytes, collision rate, CRC errors, alignment errors,

 

and total errors.

 

2

3

Image 4
Contents EtherHub-16mi+ Advanced Reference Guide EtherHub-16mi+ Internet support@accton.com.twContents Configures Communities, IP and IPX trap managers Using Configuration ProgramIsolates/attaches a hub, or sets the hubs segment Save Configuration Reset Configuration Restores the last saved configurationDefault Gateway Disable IPX protocol by setting this number to zeroSnmp Community Names This tableStatus IP Trap ManagersBackup Set Allignment ErrorsCRC Errors Total ErrorsTroubleshooting Optional Management Software