Parker Hannifin PA Series manual Environmental Guidelines, Electrical Guidelines

Page 13

Chapter 2: Installing the PowerStation

Selecting a Location

Environmental Guidelines

The environment is the area where the PA PowerStation will be located. In general, you should select a place that limits the unit’s exposure to adverse conditions such as dust, oil, moisture, and corrosive vapors.

Touchscreen Considerations

The PA PowerStation’s touchscreen is designed to meet the NEMA 4/4X rating. However, it is only rated NEMA 4/4X when properly mounted in a NEMA 4/4X enclosure.

The PA PowerStation’s touchscreen is resistant to a variety of chemicals. See Faceplate Chemical Resistance on page A-8 for a list of these chemicals. Make sure that the touchscreen is not exposed to chemicals other than those listed in Faceplate Chemical Resistance on page A-8.

Electrical Guidelines

To minimize unwanted electrical interference, select a location away from machinery that produces intense electrical noise. If you cannot do this, isolate input power to the unit and separate all data communication cables used with the unit from all AC power lines.

All serial communication cables should be 100% shielded with the shield tied to chassis ground at one end of the cable only.

See Electrical Specifications on page A-6 for a list of the PA PowerStation’s electrical specifications. Make sure that your power source is compatible with the PowerStation before starting the unit.

Field Terminal Wiring Requirements

In order to comply with UL 508 and 1604 requirements, use copper wire with 60C or 60/75C insulation and a tightening torque of 7.0 lb/in. (0.79 N- m) when connecting field terminal wiring to the PowerStation.

Temperature and Humidity Guidelines

You can safely operate the PA PowerStation within the temperature range specified in Environmental Specifications on page A-5. However, if you are using a protective enclosure, remember that the temperature within an enclosure is generally higher than the external temperature. Read these guidelines to fully understand temperature implications.

The PA PowerStation can dissipate no more than 10 watts maximum.

Heat builds up rapidly in enclosed environments, compromising the performance and life span of electrical equipment. If the PowerStation is operating inside an enclosure at temperature levels above its rated ambient temperature, you must cool the enclosure.

PA PowerStation User Guide

2-2

Image 13
Contents PowerStation Copyright and Trademark Notice Product Warranty InformationSupported Models Table of Contents Maintaining the Touchscreen -1 Cleaning the Touchscreen Maintaining the PowerStationPA PowerStation User Guide Introduction Using this ManualDownloading Applications and Projects Hardware VersionsDocumentation Standards Documentation LibraryText Conventions Style Type of TextISO Symbols Customer Support ServicesSymbol Meaning Customer SupportTechnical Training Product Technical SupportGetting Started Underwriters Laboratories Approval Selecting a LocationField Terminal Wiring Requirements Temperature and Humidity GuidelinesEnvironmental Guidelines Electrical GuidelinesPA PowerStation User Guide Radiated Emissions Guidelines Enclosure GuidelinesClass I, Division 2 Guidelines Creating the Cutout Preparing for InstallationPA Model Cutout Height Cutout Width Mounting the PA PowerStation Installing the PA PowerStationPA PowerStation User Guide Preparing a Location for the AC Power Supply Installing an Optional AC Power SupplyPrepare the Power Supply Mounting Surface Mounting the AC Power SupplyConnecting the Power Supply to the Workstation Serial Ports PowerStation ConnectorsStarting Your PowerStation COM1 Pinouts Pin# Signal Settings and Pinouts for COM11COM2 Dip Switch Settings for 5, 6, 8, and 10 Units Dip Switch Settings and Pinouts for COM2 on 15 Units 4COM2 Dip Switch Settings for 15 Units RS-485 Directional Control Transferring Files from a PC to the PA PowerStation7Serial Transfer Cable Diagram Connecting a PS/2 Mouse on 5, 6, 8, and 10 Units Connecting to a Serial PrinterConnecting a USB Mouse on 15 Units To Adjust the Mode SettingsSerial Printer Cable Diagram Ethernet Pinouts Pin# Signal To Print to a Port Configured for DownloadingEthernet Port CompactFlash Configuring the Ethernet InterfaceFile Name Description Starting the PowerStation Reinstalling the PowerStation Utilities Using the CompactFlash CardRestoring a CompactFlash Card Writing to the CompactFlash CardReformating the CompactFlash Card Using the Bios UtilityEntering Setup Using the Bios UtilityMaintaining the Touchscreen Cleaning the TouchscreenCalibrating the Touchscreen Using the MachineShop Shell Calibration UtilityDisplay Type Model No View Size Model No View Size Contrast Adjustment StepsCompactFlash Ejector Replacing the CompactFlashElectrostatic Discharge ESD Precautions Performing Internal MaintenanceOpening the PowerStation Removing the PowerStation from an EnclosureClosing the PowerStation Fuse Location PA5 PA10 on left, PA15 on right Replacing the FuseOptional Components AC Power SupplyGeneral Problem Specific Issue Resolving ProblemsLED Power indicator on the back of the unit does not light Resolving Problems when Starting UpStartup halts with the Award System Info screen displayed Resolving Problems with the Touchscreen Display appears to be blank or very dim Resolving Problems after Start UpPS/2 mouse doesn’t work 5, 6, 8, and 10 units only Keyboard doesn’t work 5, 6, 8, and 10 units onlyOrdering Replacement Components Accessing the PowerStation UtilitiesUSB keyboard or mouse doesn’t work 15 only Ethernet port doesn’t workComponent Description Powerstation Specifications CPU Physical SpecificationsTable A-4 PA08S & PA08T Display Specifications Display SpecificationsProperty PA08S Description PA08T Description Left/Right 50o/50o 65o/65o Up/Down 30o/50o 65o/55o Table A-7 Environmental Specifications Chart Category Environmental SpecificationsTable A-8 Electrical Specifications Chart Category Units Electrical SpecificationsTable A-9 European Community Specifications Test Testing SpecificationsTable A-10 Mechanical Testing Specifications MEK Faceplate Chemical ResistanceSystem Configuration Files CONFIG.SYS File System Configuration FilesTable B-1 Autoexec.bat Command Line Parameters Description AUTOEXEC.BAT File\STARTUP CD \STARTUP If Exist \STARTUP\AUTOEXEC.BAT Call Command Line Parameters DescriptionCD \NET REM Call C\NET\NET.BAT Echo END

PA Series specifications

Parker Hannifin, a global leader in motion and control technologies, has developed the PA Series, a line of advanced linear actuators designed to enhance industrial automation and machinery with reliable performance and integration capabilities. These actuators are engineered for precision, offering a range of features that cater to diverse applications in various sectors, including automotive, aerospace, and manufacturing.

One of the main features of the PA Series is its compact design, which allows for flexible installation even in limited spaces. The actuators are available in various sizes and configurations, enabling engineers to choose the most suitable option for their specific requirements. This versatility in design contributes to efficient operations, as the PA Series can be easily integrated into existing systems or used in new machinery.

The technology behind the PA Series is noteworthy for its robust construction and high durability. These actuators are built with high-quality materials that ensure long service life, even in demanding environments. They are designed to withstand mechanical stress, temperature fluctuations, and exposure to contaminants, making them ideal for use in harsh industrial conditions.

In addition to their strength, the PA Series actuators incorporate advanced motion control technologies. This includes closed-loop systems that ensure accurate positioning and repeatability. With integrated feedback mechanisms such as encoders, the actuators can provide real-time data on position and speed, allowing for precise control and adjustments during operation.

Another significant characteristic of the PA Series is its energy efficiency. The actuators are designed to minimize power consumption while maximizing output performance. This not only reduces operational costs but also supports sustainable practices in industrial operations.

Furthermore, the PA Series features a user-friendly interface for easy programming and control. This accessibility allows engineers and technicians to quickly set up and modify actuator parameters according to specific project demands. As industries continue to evolve towards automation, the flexibility and scalability of the PA Series make it an ideal choice for companies looking to enhance their productivity and efficiency.

Overall, the Parker Hannifin PA Series stands out for its innovative design, superior technology, and reliable performance. Whether deployed in robotics, assembly lines, or material handling applications, these actuators are engineered to meet the rigorous demands of modern industrial automation.