Parker Hannifin PA Series Installing an Optional AC Power Supply, Mounting the AC Power Supply

Page 20

Chapter 2: Installing the PowerStation

Installing an Optional AC Power Supply

Installing an Optional AC Power Supply

The PA PowerStation uses only 12 or 24 volt DC power. However, you can operate the PowerStation with AC power by using an optional AC Power Supply available from Parker. Use this section only if you intend to operate the PA PowerStation using AC power. If you plan to use DC power, refer to Installing the PA PowerStation on page 2-7.

Caution: Do not apply AC power directly to the unit or damage may occur.

Preparing a Location for the AC Power Supply

Be sure to select a location that provides protection from dust, oil, moisture, and corrosive vapors. If your enclosure is large enough, you can mount the Power Supply in the enclosure with the unit.

If you purchased Parker’s optional AC Power Supply and mounting kit use the template that came with the mounting kit to prepare your location for the power supply. This can be inside or outside the enclosure where the PowerStation is installed.

Note: If you decide to mount the Power Supply in an enclosure, mount it on the bottom or on the side of the enclosure to provide the best convection cooling.

Prepare the Power Supply Mounting Surface

The P1X-PWRAC AC power supply is designed to be mounted using two metal brackets provided in the optional BKT-1000 mounting kit. These brackets are secured to the mounting surface using four screws. To prepare the mounting surface, complete the following steps:

1Measure the cutout dimensions.

2Securely attach the power supply template to the mounting surface.

3Cutout the four 0.17” (4.3mm) holes as shown on the template.

4Debur the edges of the cutout area, removing dirt and debris.

Mounting the AC Power Supply

After drilling the holes for the four screws, you can follow the steps below to mount the power supply:

1Attach the power supply to the mounting surface using the supplied metal brackets.

2Connect the power cord from the power supply to an AC power source.

3Attach the ferrite to the section of the cord closest to the loose wires. The ferrite is located in the PA mounting kit.

PA PowerStation User Guide

2-9

Image 20
Contents PowerStation Supported Models Product Warranty InformationCopyright and Trademark Notice Table of Contents Maintaining the PowerStation Maintaining the Touchscreen -1 Cleaning the TouchscreenPA PowerStation User Guide Using this Manual IntroductionHardware Versions Downloading Applications and ProjectsDocumentation Library Documentation StandardsText Conventions Style Type of TextCustomer Support Services ISO SymbolsSymbol Meaning Customer SupportProduct Technical Support Technical TrainingGetting Started Selecting a Location Underwriters Laboratories ApprovalTemperature and Humidity Guidelines Field Terminal Wiring RequirementsEnvironmental Guidelines Electrical GuidelinesPA PowerStation User Guide Enclosure Guidelines Radiated Emissions GuidelinesClass I, Division 2 Guidelines PA Model Cutout Height Cutout Width Preparing for InstallationCreating the Cutout Installing the PA PowerStation Mounting the PA PowerStationPA PowerStation User Guide Installing an Optional AC Power Supply Preparing a Location for the AC Power SupplyPrepare the Power Supply Mounting Surface Mounting the AC Power SupplyConnecting the Power Supply to the Workstation PowerStation Connectors Serial PortsStarting Your PowerStation Settings and Pinouts for COM1 COM1 Pinouts Pin# Signal1COM2 Dip Switch Settings for 5, 6, 8, and 10 Units Dip Switch Settings and Pinouts for COM2 on 15 Units 4COM2 Dip Switch Settings for 15 Units Transferring Files from a PC to the PA PowerStation RS-485 Directional Control7Serial Transfer Cable Diagram Connecting to a Serial Printer Connecting a PS/2 Mouse on 5, 6, 8, and 10 UnitsConnecting a USB Mouse on 15 Units To Adjust the Mode SettingsSerial Printer Cable Diagram Ethernet Port To Print to a Port Configured for DownloadingEthernet Pinouts Pin# Signal File Name Description Configuring the Ethernet InterfaceCompactFlash Starting the PowerStation Using the CompactFlash Card Reinstalling the PowerStation UtilitiesRestoring a CompactFlash Card Writing to the CompactFlash CardUsing the Bios Utility Reformating the CompactFlash CardUsing the Bios Utility Entering SetupCleaning the Touchscreen Maintaining the TouchscreenDisplay Type Model No View Size Using the MachineShop Shell Calibration UtilityCalibrating the Touchscreen Contrast Adjustment Steps Model No View SizeReplacing the CompactFlash CompactFlash EjectorPerforming Internal Maintenance Electrostatic Discharge ESD PrecautionsRemoving the PowerStation from an Enclosure Opening the PowerStationClosing the PowerStation Replacing the Fuse Fuse Location PA5 PA10 on left, PA15 on rightAC Power Supply Optional ComponentsResolving Problems General Problem Specific IssueStartup halts with the Award System Info screen displayed Resolving Problems when Starting UpLED Power indicator on the back of the unit does not light Resolving Problems with the Touchscreen Resolving Problems after Start Up Display appears to be blank or very dimPS/2 mouse doesn’t work 5, 6, 8, and 10 units only Keyboard doesn’t work 5, 6, 8, and 10 units onlyAccessing the PowerStation Utilities Ordering Replacement ComponentsUSB keyboard or mouse doesn’t work 15 only Ethernet port doesn’t workComponent Description Powerstation Specifications Physical Specifications CPUProperty PA08S Description PA08T Description Display SpecificationsTable A-4 PA08S & PA08T Display Specifications Left/Right 50o/50o 65o/65o Up/Down 30o/50o 65o/55o Environmental Specifications Table A-7 Environmental Specifications Chart CategoryElectrical Specifications Table A-8 Electrical Specifications Chart Category UnitsTable A-10 Mechanical Testing Specifications Testing SpecificationsTable A-9 European Community Specifications Test Faceplate Chemical Resistance MEKSystem Configuration Files System Configuration Files CONFIG.SYS FileTable B-1 Autoexec.bat Command Line Parameters Description AUTOEXEC.BAT FileCommand Line Parameters Description \STARTUP CD \STARTUP If Exist \STARTUP\AUTOEXEC.BAT CallCD \NET REM Call C\NET\NET.BAT Echo END

PA Series specifications

Parker Hannifin, a global leader in motion and control technologies, has developed the PA Series, a line of advanced linear actuators designed to enhance industrial automation and machinery with reliable performance and integration capabilities. These actuators are engineered for precision, offering a range of features that cater to diverse applications in various sectors, including automotive, aerospace, and manufacturing.

One of the main features of the PA Series is its compact design, which allows for flexible installation even in limited spaces. The actuators are available in various sizes and configurations, enabling engineers to choose the most suitable option for their specific requirements. This versatility in design contributes to efficient operations, as the PA Series can be easily integrated into existing systems or used in new machinery.

The technology behind the PA Series is noteworthy for its robust construction and high durability. These actuators are built with high-quality materials that ensure long service life, even in demanding environments. They are designed to withstand mechanical stress, temperature fluctuations, and exposure to contaminants, making them ideal for use in harsh industrial conditions.

In addition to their strength, the PA Series actuators incorporate advanced motion control technologies. This includes closed-loop systems that ensure accurate positioning and repeatability. With integrated feedback mechanisms such as encoders, the actuators can provide real-time data on position and speed, allowing for precise control and adjustments during operation.

Another significant characteristic of the PA Series is its energy efficiency. The actuators are designed to minimize power consumption while maximizing output performance. This not only reduces operational costs but also supports sustainable practices in industrial operations.

Furthermore, the PA Series features a user-friendly interface for easy programming and control. This accessibility allows engineers and technicians to quickly set up and modify actuator parameters according to specific project demands. As industries continue to evolve towards automation, the flexibility and scalability of the PA Series make it an ideal choice for companies looking to enhance their productivity and efficiency.

Overall, the Parker Hannifin PA Series stands out for its innovative design, superior technology, and reliable performance. Whether deployed in robotics, assembly lines, or material handling applications, these actuators are engineered to meet the rigorous demands of modern industrial automation.