Installing the PA PowerStation

Installing the PA PowerStation

Once you have prepared the location for your PowerStation, you are ready to install the unit. To do so, you need to mount the PowerStation to your enclosure using screws and metal clamps in what is called a bracket assembly. The bracket assembly contains a mounting clamp with “feet” and a screw.

The number of clamps depends on the PA PowerStation model. The shape of the prongs at the bottom of each clamp also depends on the model. The 5”, 6”, and 8” models use a T-shape clamp, and the 10” and 15” models use an L-shape clamp.

The mounting clamps secure to the PowerStation using a sliding mechanism. You must slide the feet of the mounting clamp into the appropriate slot on the PowerStation.

For your convenience, all necessary mounting hardware is included with the unit.

Mounting the PA PowerStation

Complete the instructions below:

1Slide the PowerStation into the cutout from the front.

2Attach the 4-8 mounting clamps, with their screws to the back of the unit in the spaces provided.

The clamps secure to the unit using the sliding mechanism shown in Figure 2-1 for 5”, 6” and 8” units or Figure 2-2 for 10” and 15” units.

Figure 2-1: Sliding Mechanism for the 5”, 6”, and 8” PA PowerStations

Figure 2-2: Sliding Mechanism for the 10” and 15” PA PowerStations

PA PowerStation User Guide

2-7

Image 18
Contents PowerStation Product Warranty Information Copyright and Trademark NoticeSupported Models Table of Contents Maintaining the PowerStation Maintaining the Touchscreen -1 Cleaning the TouchscreenPA PowerStation User Guide Using this Manual IntroductionHardware Versions Downloading Applications and ProjectsText Conventions Documentation LibraryDocumentation Standards Style Type of TextSymbol Meaning Customer Support ServicesISO Symbols Customer SupportProduct Technical Support Technical TrainingGetting Started Selecting a Location Underwriters Laboratories ApprovalEnvironmental Guidelines Temperature and Humidity GuidelinesField Terminal Wiring Requirements Electrical GuidelinesPA PowerStation User Guide Enclosure Guidelines Radiated Emissions GuidelinesClass I, Division 2 Guidelines Preparing for Installation Creating the CutoutPA Model Cutout Height Cutout Width Installing the PA PowerStation Mounting the PA PowerStationPA PowerStation User Guide Prepare the Power Supply Mounting Surface Installing an Optional AC Power SupplyPreparing a Location for the AC Power Supply Mounting the AC Power SupplyConnecting the Power Supply to the Workstation PowerStation Connectors Serial PortsStarting Your PowerStation Settings and Pinouts for COM1 COM1 Pinouts Pin# Signal1COM2 Dip Switch Settings for 5, 6, 8, and 10 Units Dip Switch Settings and Pinouts for COM2 on 15 Units 4COM2 Dip Switch Settings for 15 Units Transferring Files from a PC to the PA PowerStation RS-485 Directional Control7Serial Transfer Cable Diagram Connecting a USB Mouse on 15 Units Connecting to a Serial PrinterConnecting a PS/2 Mouse on 5, 6, 8, and 10 Units To Adjust the Mode SettingsSerial Printer Cable Diagram To Print to a Port Configured for Downloading Ethernet Pinouts Pin# SignalEthernet Port Configuring the Ethernet Interface CompactFlashFile Name Description Starting the PowerStation Restoring a CompactFlash Card Using the CompactFlash CardReinstalling the PowerStation Utilities Writing to the CompactFlash CardUsing the Bios Utility Reformating the CompactFlash CardUsing the Bios Utility Entering SetupCleaning the Touchscreen Maintaining the TouchscreenUsing the MachineShop Shell Calibration Utility Calibrating the TouchscreenDisplay Type Model No View Size Contrast Adjustment Steps Model No View SizeReplacing the CompactFlash CompactFlash EjectorPerforming Internal Maintenance Electrostatic Discharge ESD PrecautionsRemoving the PowerStation from an Enclosure Opening the PowerStationClosing the PowerStation Replacing the Fuse Fuse Location PA5 PA10 on left, PA15 on rightAC Power Supply Optional ComponentsResolving Problems General Problem Specific IssueResolving Problems when Starting Up LED Power indicator on the back of the unit does not lightStartup halts with the Award System Info screen displayed Resolving Problems with the Touchscreen PS/2 mouse doesn’t work 5, 6, 8, and 10 units only Resolving Problems after Start UpDisplay appears to be blank or very dim Keyboard doesn’t work 5, 6, 8, and 10 units onlyUSB keyboard or mouse doesn’t work 15 only Accessing the PowerStation UtilitiesOrdering Replacement Components Ethernet port doesn’t workComponent Description Powerstation Specifications Physical Specifications CPUDisplay Specifications Table A-4 PA08S & PA08T Display SpecificationsProperty PA08S Description PA08T Description Left/Right 50o/50o 65o/65o Up/Down 30o/50o 65o/55o Environmental Specifications Table A-7 Environmental Specifications Chart CategoryElectrical Specifications Table A-8 Electrical Specifications Chart Category UnitsTesting Specifications Table A-9 European Community Specifications TestTable A-10 Mechanical Testing Specifications Faceplate Chemical Resistance MEKSystem Configuration Files Table B-1 Autoexec.bat Command Line Parameters Description System Configuration FilesCONFIG.SYS File AUTOEXEC.BAT FileCommand Line Parameters Description \STARTUP CD \STARTUP If Exist \STARTUP\AUTOEXEC.BAT CallCD \NET REM Call C\NET\NET.BAT Echo END

PA Series specifications

Parker Hannifin, a global leader in motion and control technologies, has developed the PA Series, a line of advanced linear actuators designed to enhance industrial automation and machinery with reliable performance and integration capabilities. These actuators are engineered for precision, offering a range of features that cater to diverse applications in various sectors, including automotive, aerospace, and manufacturing.

One of the main features of the PA Series is its compact design, which allows for flexible installation even in limited spaces. The actuators are available in various sizes and configurations, enabling engineers to choose the most suitable option for their specific requirements. This versatility in design contributes to efficient operations, as the PA Series can be easily integrated into existing systems or used in new machinery.

The technology behind the PA Series is noteworthy for its robust construction and high durability. These actuators are built with high-quality materials that ensure long service life, even in demanding environments. They are designed to withstand mechanical stress, temperature fluctuations, and exposure to contaminants, making them ideal for use in harsh industrial conditions.

In addition to their strength, the PA Series actuators incorporate advanced motion control technologies. This includes closed-loop systems that ensure accurate positioning and repeatability. With integrated feedback mechanisms such as encoders, the actuators can provide real-time data on position and speed, allowing for precise control and adjustments during operation.

Another significant characteristic of the PA Series is its energy efficiency. The actuators are designed to minimize power consumption while maximizing output performance. This not only reduces operational costs but also supports sustainable practices in industrial operations.

Furthermore, the PA Series features a user-friendly interface for easy programming and control. This accessibility allows engineers and technicians to quickly set up and modify actuator parameters according to specific project demands. As industries continue to evolve towards automation, the flexibility and scalability of the PA Series make it an ideal choice for companies looking to enhance their productivity and efficiency.

Overall, the Parker Hannifin PA Series stands out for its innovative design, superior technology, and reliable performance. Whether deployed in robotics, assembly lines, or material handling applications, these actuators are engineered to meet the rigorous demands of modern industrial automation.