A d j u s t i n g t h e S u p p l y S e n s o r
To detect the label edge and/or black mark for all supply sizes, the supply sensor is adjustable across half of the supply path. Adjust the position of the supply sensor when changing from a wider to a narrower supply size. This keeps the supply sensor positioned to detect the label edge.
Rotating the adjustment knob clockwise sets the sensor for wider supply. In general, if you keep the knob in the full counterclockwise position, it correctly senses supply. However, if you have a problem sensing Top Of Form, try rotating this knob clockwise
CAUTION
Do not force or
Sensor
Adjustment Knob