3Com S200 manual Description Terms Second Screen

Page 78

ATPAD Ports

Description of

Terms — Second

Screen

The second Detailed PAD Port Statistics screen contains this information:

Screen Term

Tells You...

 

 

Call Summary

• Current Status: Status of the call on

 

the specific port (Data Transfer,

 

Calling, Called, Clearing,

 

Connected, Local Copy)

 

• Last Clear Cause Code: Last clear

 

cause code received by the port

 

• Last Clear Diagnostic Code: Last

 

clear diagnostic code received by

 

the port

 

 

Last Inbound Call

Called Address, Calling Address,

 

Facilities, and CUD of the last inbound

 

call

 

 

Last Outbound Call

Called Address, Calling Address,

 

Facilities, and CUD of the last outbound

 

call

 

 

 

 

72

Configuring PAD/ATPAD Ports

Image 78
Contents 3Com Corporation Restricted Rights Notification for U.S. Government Users Restricted Rights LegendProprietary Material Page Contents Page Introduction Configuring PAD/ATPAD PortsOverview Before You BeginAbout Packet Assembler/Disassembler Typical Applications ExamplePAD Port Configuration Configuration RecordPAD Port Guidelines If You Specify or Set ThenStep Action Result Parameters Connection TypeUse Connection Type When Use Connection Type Port ControlCRONLY, CRDOTCR, TYMNET, Telenet Port SpeedAuto Baud Sequence CronlyNONE, SPAC, MARK, EVEN, ODD, Auto Data Bits per CharacterDevice Parity Number of Stop BitsCall Control NONE, AUTO, AUTC, PCUD, IBAR, OBAR, MNEM, TmnemTerminal Control NONE, PASS, LIM, CUG, LCPY, 7BIT, NADD, X.28, CnuiCUGOA, BMSG, ADDR, FRCB, Cugia Remote PAD Parameters Number Autocall Timeout secPAD Prompt Entry Number Autocall MnemonicGroup Subaddress Maximum Number of Autocall AttemptsSubaddress CUG MembershipCall Accept Timeout sec Billing RecordsInvitation to clear NONE, CPONLY, Fulldcp Reconnection TimeoutProtection Level Reconnection Tries LimitCalled DTE Address Calling DTE PasswordMaximum Receive Buffer Length Calling DTE IdentifierNUI Facility Format PAD Command LanguageNUI verification timer Max NUI violationsAction Type for NUI violations NONE, DISC, DEGR, LockPAD Port Configuration for Autocalling Initiating an AutoCall Mnemonic AddressingSdlc Mnemonic Addressing Sdlc Mnemonic Autocall AddressingPAD Port Configuration for Autospeed PAD XON/OFF Support Using X.25 Interrupt Packets How It WorksStep Action What You See Before You Begin Accessing the PAD Prompt Table RecordPAD Prompt Table Record This RecordPAD Prompt Table Record Parameters Entry NumberPAD Prompt Text PAD Profile Table Record Introduction What You See In This RecordConfiguration Guidelines Accessing the PAD Profile Table RecordSelect PAD Profile Table from PAD Profile Table Record Parameters #1, PAD Recall#4, Idle Timer Delay #2, Echo#3, Data Forwarding Character #6, Service Signals Control #5, Device Flow Control#7, Break Signal Operation #9, Padding After Carriage Return#10, Line Folding #12, PAD Data Restraint #13, Line Feed Insertion after CR#16, Character Delete #14, Padding after LF#15, Editing #17, Line Delete#18, Line Display #19, Editing Type#20, Echo Mask #21 Parity Treatment#101, Echo Substitution Toggle Character #22, Page Wait#100, Break Character #102, Echo Substitution Character#105, Control Signal EIA-232-D Data Restraint #103, XON Character#104, Xoff Character #107, Idle Disconnect Timer #106, Network Parity#108, Disconnect Character #110, Esc Forwarding Delay Handling #109, Form Feed Padding#111, Echo Control #112, Dynamic Data Forwarding#113, Hewlett-Packard Flow Control #114, PAD Mode #116, Short Timer Duration#115, Data Forwarding Criteria #117, EIA Signalling Action #118, Message Assembly#119, DCD to Data Timer Duration Size Copying PAD Profile Tables into a ConfigurationPAD Profile Table Select Copy/Insert RecordParameter Name Default Test Simple Transpar Parameter Values Stored In MemoryPrinter Parameter Name TPA Hpea Hpxon Host RmotTPA Hpea Hpxon Host Rmot Parameter INT1984 IRANSP1 PAD BulletinMessage Remote PAD Parameter Table Record Select Remote PAD ParameterRemote PAD Parameter Table Record Parameters #1 Parameter Number #1 Parameter Value Description Terms First Screen Detailed PAD Port StatisticsFunction Screen Term Tells YouNull Example of Detailed PAD Port Statistics, Second ScreenDescription Terms Second Screen Example of Detailed PAD Port Statistics, Third Screen Atpad Ports Criteria Descriptions Atpad OperationData Forwarding Criteria If you want to Then useFlow Control XON/XOFFNetwork Parity Application Response Delay DTR Timeout Atpad Application EnvironmentConfiguration Use these guidelines when you enter Atpad commandsConfigure Atpad Port Menu PAD Port TypeNULL, PAD, X25, SDLC, FRI, ATPAD, PPP SIMP, DTRNONE, SPAC, MARK, EVEN, ODD Data BitsParity Stop BitsBack Space Character Carriage Return CharacterLine Feed Character Data Forwarding CharacterXON Character Escape Sequence TimerData Forwarding Timer NONE, CNTL, XoffEcho Answer ModePacket Size Stored AddressesAlpha Result CodesALPHA, NUM, None Restricted Connection DestinationProtocol ID Network ParityNONE, SPAC, MARK, Even Atpad Port Statistics Atpad Port Statistics ScreenNull Description Terms Second Screen Technical Support Access by Analog Modem Country Data Rate Telephone NumberSupport from 3ComCountry Telephone Number Returning Country Telephone Number Fax NumberNumerics SymbolsIndex ApadIndex-2 Sdlc URL
Related manuals
Manual 31 pages 49.52 Kb Manual 12 pages 51.58 Kb

S200 specifications

The 3Com S200 is a cutting-edge networking solution designed to meet the demands of small to medium-sized businesses. Renowned for its reliability and performance, this switch offers seamless integration and enhances network efficiency through advanced features and technologies.

One of the standout features of the 3Com S200 is its versatility. With a variety of ports ranging from 8 to 48, the switch provides ample connectivity options for various devices. This flexibility makes it an ideal choice for businesses aiming to expand their network without the need for extensive infrastructure changes. Built-in support for Power over Ethernet (PoE) enables users to connect and power devices such as IP phones and cameras, simplifying wiring and installation.

Performance is another key characteristic of the 3Com S200. Equipped with Layer 2 switching capabilities, the S200 allows for intelligent traffic management and efficient data handling. It supports advanced features like VLAN tagging, which facilitates network segmentation, improving security and performance. Additionally, the switch boasts a user-friendly interface that enables streamlined management, making network monitoring and configuration easily accessible even for non-technical staff.

The durability and reliability of the 3Com S200 are further enhanced by its robust design. Built to handle the rigors of a business environment, the switch features a fanless design for quiet operation, making it suitable for office use where noise may be an issue. With energy-efficient technology, the S200 not only minimizes power consumption but also contributes to cost savings over time.

Security is a priority for modern networks, and the 3Com S200 excels in this area. It offers features such as port security and access control lists to protect sensitive data and manage user access. Moreover, support for SNMP (Simple Network Management Protocol) facilitates proactive network management and monitoring, allowing businesses to address potential issues before they escalate.

In conclusion, the 3Com S200 stands out as a reliable, efficient, and secure networking solution. With its versatile port options, Layer 2 capabilities, user-friendly management interface, and robust security features, it is an excellent choice for businesses looking to enhance their network infrastructure. Whether scaling operations or optimizing current performance, the 3Com S200 provides the technology and reliability needed to thrive in today’s digital landscape.