3Com 8810 3Com Corporation Campus Drive Marlborough, MA USA, United States Government Legend

Page 2

3Com Corporation

350 Campus Drive

Marlborough, MA

USA 01752-3064

Copyright © 2006-2007, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corporation.

3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.

3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.

If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.

UNITED STATES GOVERNMENT LEGEND

If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:

All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.

Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.

3Com and the 3Com logo are registered trademarks of 3Com Corporation.

Cisco is a registered trademark of Cisco Systems, Inc.

Funk RADIUS is a registered trademark of Funk Software, Inc.

Aegis is a registered trademark of Aegis Group PLC.

Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.

IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.

All other company and product names may be trademarks of the respective companies with which they are associated.

ENVIRONMENTAL STATEMENT

It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we are committed to:

Establishing environmental performance standards that comply with national legislation and regulations.

Conserving energy, materials and natural resources in all operations.

Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized environmental standards. Maximizing the recyclable and reusable content of all products.

Ensuring that all products can be recycled, reused and disposed of safely.

Ensuring that all products are labelled according to recognized environmental standards.

Improving our environmental record on a continual basis.

End of Life Statement

3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.

Regulated Materials Statement

3Com products do not contain any hazardous or ozone-depleting material.

Image 2
Contents 3Com Switch 8800 Family 3Com Corporation Campus Drive Marlborough, MA USA United States Government LegendContents System Debugging Protocols that are used to interconnect LANs About this GuideConventions Lists icon conventions that are used throughout this guideRelated SwitchUsing the supported protocols and CLI commands Documentation8800s Product OverviewPreface 3Com Switch 8810 10-Slot Chassis 3Com Switch 8814 14-Slot Chassis Chassis and Slots Switch Switch 8807 slotsSwitch Switch 8810 slotsFunctions StructureEach Ethernet port can deliver up to 15.4 W to its PD AC Power SystemSpecifications Switch External PoE Power Rack 3C17509 PoE entry areaLabel Color State Abnormal reason Mbus IntroductionNormal Abnormal Fan tray panel of the Switch 8800 Family Role and functionPanel Gbps Switch FabricFabric Modules Management Ports RS232/485 port specificationsCompact Flash CF slot Status LEDs for the management 10Base-T/100Base-TX portAUX port specifications Reset buttonConsole port specifications Status LEDsCF status LED Status LEDs for the 360 Gbps Switch Fabric moduleGbps Switch Fabric LED Status Status LEDs for I/O moduleGbps Switch Fabric Technical specifications 720 Gbps Switch Fabric specificationsAUX port Status LEDs for the 720 Gbps Switch Fabric module Status LEDs for the 720 Gbps Switch Fabric module Technical specifications of the Switch 8800 FamilySoftware features of the Switch 8800 Family Software FeaturesSupported software features Lacp Software features of the Switch 8800 Family Product Overview Application Modules O modules available to the Switch 8800 Family3C17511 module specifications OverviewPanel and LEDs 3C17511 module panel 3C17512 module specifications3C17512 2-port 10GBASE-X XFP Module Port LEDs on the 3C17511 module3C17513 module has two LEDs for each port on its panel Specifications3C17513 12-port 1000BASE-X SFP Module Port LEDs on the 3C17513 module 3C17514 module specifications3C17514 24-port 1000BASE-X SFP Module Panel and LEDs 3C17514 module panelPort LEDs on the 3C17516 module 3C17525 1-port 10GBASE-X Advanced Xenpak Module3C17516 module has one LED for each port on its panel Panel and LEDs 3C17525 module panel 3C17526 module specifications3C17526 4-port 10GBASE-X XFP Module Port LEDs on the 3C17525 modulePanel and LEDs 3C17526 module panel 3C17527 module specifications3C17527 2-port 10GBASE-X XFP Advanced Module 1000 Mbps optical port LEDs on the 3C17526 module3C17528 48port 10/100/1000 BASE-T RJ-45 Module 3C17528 module has one LED for each port on its panelPanel and LEDs 3C17530 module panel 3C17530 24-port 1000BASE-X SFP Advanced Module3C17531 24-port 10/100/1000BASE-T Advanced Module Panel and LEDs 3C17531 module panel 3C17532 module specifications3C17531 module has one LED for each port on its panel Port LEDs on the 3C17531 modulePanel and LEDs 3C17533 module panel 3C17533 24-port 1000BASE-X SFP IPv6 Module3C17532 module has one LED for each port on their panel 3C17534 24-port 10/100/1000BASE-T IPv6 Module 3C17534 module specifications3C17536 module specifications 3C17536 4-port 10GBASE-X XFP Quad IPv6 ModulePanel and LEDs 3C17536 module panel 3C17538 module specifications3C17538 48-port 1000BASE-X SFP IPv6 Module 1000 Mbps optical port LEDs on the 3C17536 modulePanel and LEDs 3C17538 module panel Technical specifications for the 3C17542Front panel Port LEDs on the 3C17538 moduleAvailable cables Technical specifications for the 3C17546Technical specifications for the 3CR1754766 Status LEDs on the 3C17546Technical specifications for the 3C17548 Status LEDs on the 3CR1754766Transceivers Documents the 3Com Switch 8800 Family transceiversTransceiver Specifications Densities Switch 8800 PortSwitch 8800 Available Modules Description Max PortGeneral Safety Installation PreparationSafety RecommendationsInstallation Preparation Harmful gas limits in an equipment room Limitation on dust content in equipment roomMechanical active material Unit Content Gas Average mg/m3 Max. mg/m3Required installation tools Installation ToolsPower Supply Requirements Space Requirements MeasureInstallation Flow Switch InstallationConfirming Installation Preparation Mounting the Switch User-Supplied Cabinet One Switch 8807 chassis in a cabinetTwo Switch 8807 chassis in a cabinet One Switch 8807 chassis in a cabinet Switch 8807 11UOne Switch 8810 chassis in a cabinet Two Switch 8807 chassis in a cabinet Switch 8807 11UOne Switch 8814 chassis in a cabinet One Switch 8810 chassis in a cabinet Switch 8810 14UOne Switch 8814 chassis in a cabinet Switch 8814 17U CabinetOther grounding environment Connecting Pgnd Wire and Power CordConnecting Pgnd Wire Common grounding environment Ground the switch when ground bar is available Connecting AC Power Cord Ground the switch via AC PE wireConnect AC power cord to the Switch Connecting PoE power cable Grounding PoE chassisFan tray is hot swappable Installing Fan TrayInstall mounting ears onto the both sides of the switch Lightning Protection Box Contact take the fan tray out from the packing bagInstalling I/O modules Fasten the screw on top of the PoE lightning protection boxRJ-45 Signal Direction DB-25 DB-9 Connecting Interface CablesConnecting console cable IntroductionAUX cable AUX cable pinoutsConnecting category-5 shielded cable Connecting AUX cableIntroduction to RJ-45 connector Connecting FiberIntertwinement or bending is allowed Cable Routing RecommendationsCable Management Cable bundling example Cable fixing example Tie-binding parameters Verifying InstallationInstallation checking list Cable bundle diameter mm Space between bundles mmSwitch Installation System Debugging Setting up Configuration EnvironmentSetting up EnvironmentPowering and Booting the Switch Verifying Installation Before Powering SwitchZbbtest System Debugging Description of the LEDs on PSU Switch Monitoring MaintenanceTroubleshooting PSU Indicator State description Description of fan tray LEDsIndicator Hardware MaintenanceRemoving AC PSU Switch 8807 as example Replacing AC PSUInstalling AC PSU Switch 8807 as example Remove and install the AC PSURemoving and cleaning the air filter of PSU Installing the air filter of PSUInstalling the air filter of the chassis Replacing and Cleaning Air Filter of ChassisRemoving and cleaning the air filter of chassis Required toolsGently pull the module out of the slot along the guides Installing a ModuleRemoving a module Replacing the Fan Tray Required toolsRequired cables Software UpgradeRecommended upgrade procedure Boot menu Press Ctrl+B as prompted and the system will displayUpgrading software through console port XModem Main MenuA Windows 98 operating system environment, you can perform Serial SubmenuUpgrading software through management Ethernet port Tftp Send File dialog boxFiles using Tftp and to 0x0 if using FTP Upgrading software through management Ethernet port FTP Loading using FTP Remote and local loading using Tftp Load host programNo configuration saving during I/O module reboot Password LossSoftware Upgrade No response from fabric serial interface Insufficient Flash memorySwitch Monitoring and Maintenance Lightning Protection Switch Diagram of lightning arresterIs not well grounded yet Installation Lightning Arrester for Network PortInstallation procedure Installation precautions Use the nylon ties to bundle the cables neatly
Related manuals
Manual 104 pages 36.87 Kb