3Com 8814, 8807, 8810 manual Product Overview, Preface, 8800s

Page 7

1

PRODUCT OVERVIEW

Preface

3Com Switch 8800 Family of Routing Switches (hereinafter referred to as Switch

 

8800 Family) are intelligent, multi-layer modular LAN switches is ideal for

 

enterprise environments where non-stop availability of critical applications and the

 

highest performance, security, and granular control are required. The Switch 8800

 

Family delivers high density Gigabit and 10 Gigabit switching in an integrated

 

chassis platform. Built-in support for IPv6, MPLS, Power over Ethernet (PoE), and

 

1.44 Tbps backplane capacity ensures unprecedented investment protection.

 

Resilient Layer-3 routing, hot-swap modules, and redundant power, along with

 

sub one-second fabric fail over on the Switch 8800, ensure (24 x 7) availability to

 

support the most demanding enterprise core and campus environments.

 

Advanced Quality of Service features such as bandwidth management and packet

 

classification optimize quality for real-time voice and video applications. Intrusion

 

prevention security capabilities such as IEEE 802.1X Network Login and Access

 

Control Lists ensure that only authorized users can access network resources.

 

The Switch 8800 is focused on delivering functionality towards the higher end of

 

the large Enterprise, with a 4-port 10 Gigabit Module, high density 48-port

 

Gigabit Modules, as well as a group of Advanced Modules with support for larger

 

routing tables and/or MPLS. Power over Ethernet (PoE) is built into all Switch

 

8800s.

 

Application modules for the Switch 8800 provide the flexibility to add a firewall,

 

IPsec encryption, network monitoring with NetFlow, and Layer 2 VPN networking

 

using Virtual Private LAN Service (VPLS) by simply adding a module to the chassis.

Image 7
Contents 3Com Switch 8800 Family United States Government Legend 3Com Corporation Campus Drive Marlborough, MA USAContents System Debugging Lists icon conventions that are used throughout this guide About this GuideConventions Protocols that are used to interconnect LANsDocumentation SwitchUsing the supported protocols and CLI commands RelatedPreface Product Overview8800s 3Com Switch 8810 10-Slot Chassis 3Com Switch 8814 14-Slot Chassis Switch 8807 slots Chassis and Slots SwitchSwitch 8810 slots SwitchStructure FunctionsSpecifications Switch AC Power SystemEach Ethernet port can deliver up to 15.4 W to its PD PoE entry area External PoE Power Rack 3C17509Normal Abnormal Mbus IntroductionLabel Color State Abnormal reason Role and function Fan tray panel of the Switch 8800 FamilyFabric Modules Gbps Switch FabricPanel Status LEDs for the management 10Base-T/100Base-TX port RS232/485 port specificationsCompact Flash CF slot Management PortsStatus LEDs Reset buttonConsole port specifications AUX port specificationsStatus LEDs for I/O module Status LEDs for the 360 Gbps Switch Fabric moduleGbps Switch Fabric LED Status CF status LED720 Gbps Switch Fabric specifications Gbps Switch Fabric Technical specificationsAUX port Status LEDs for the 720 Gbps Switch Fabric module Technical specifications of the Switch 8800 Family Status LEDs for the 720 Gbps Switch Fabric moduleSupported software features Software FeaturesSoftware features of the Switch 8800 Family Lacp Software features of the Switch 8800 Family Product Overview Overview O modules available to the Switch 8800 Family3C17511 module specifications Application ModulesPort LEDs on the 3C17511 module 3C17512 module specifications3C17512 2-port 10GBASE-X XFP Module Panel and LEDs 3C17511 module panel3C17513 12-port 1000BASE-X SFP Module Specifications3C17513 module has two LEDs for each port on its panel Panel and LEDs 3C17514 module panel 3C17514 module specifications3C17514 24-port 1000BASE-X SFP Module Port LEDs on the 3C17513 module3C17516 module has one LED for each port on its panel 3C17525 1-port 10GBASE-X Advanced Xenpak ModulePort LEDs on the 3C17516 module Port LEDs on the 3C17525 module 3C17526 module specifications3C17526 4-port 10GBASE-X XFP Module Panel and LEDs 3C17525 module panel1000 Mbps optical port LEDs on the 3C17526 module 3C17527 module specifications3C17527 2-port 10GBASE-X XFP Advanced Module Panel and LEDs 3C17526 module panel3C17528 module has one LED for each port on its panel 3C17528 48port 10/100/1000 BASE-T RJ-45 Module3C17531 24-port 10/100/1000BASE-T Advanced Module 3C17530 24-port 1000BASE-X SFP Advanced ModulePanel and LEDs 3C17530 module panel Port LEDs on the 3C17531 module 3C17532 module specifications3C17531 module has one LED for each port on its panel Panel and LEDs 3C17531 module panel3C17532 module has one LED for each port on their panel 3C17533 24-port 1000BASE-X SFP IPv6 ModulePanel and LEDs 3C17533 module panel 3C17536 4-port 10GBASE-X XFP Quad IPv6 Module 3C17534 module specifications3C17536 module specifications 3C17534 24-port 10/100/1000BASE-T IPv6 Module1000 Mbps optical port LEDs on the 3C17536 module 3C17538 module specifications3C17538 48-port 1000BASE-X SFP IPv6 Module Panel and LEDs 3C17536 module panelPort LEDs on the 3C17538 module Technical specifications for the 3C17542Front panel Panel and LEDs 3C17538 module panelStatus LEDs on the 3C17546 Technical specifications for the 3C17546Technical specifications for the 3CR1754766 Available cablesStatus LEDs on the 3CR1754766 Technical specifications for the 3C17548Transceiver Specifications Documents the 3Com Switch 8800 Family transceiversTransceivers Description Max Port Switch 8800 PortSwitch 8800 Available Modules DensitiesRecommendations Installation PreparationSafety General SafetyInstallation Preparation Gas Average mg/m3 Max. mg/m3 Limitation on dust content in equipment roomMechanical active material Unit Content Harmful gas limits in an equipment roomMeasure Installation ToolsPower Supply Requirements Space Requirements Required installation toolsConfirming Installation Preparation Switch InstallationInstallation Flow One Switch 8807 chassis in a cabinet Mounting the Switch User-Supplied CabinetOne Switch 8807 chassis in a cabinet Switch 8807 11U Two Switch 8807 chassis in a cabinetTwo Switch 8807 chassis in a cabinet Switch 8807 11U One Switch 8810 chassis in a cabinetOne Switch 8810 chassis in a cabinet Switch 8810 14U One Switch 8814 chassis in a cabinetCabinet One Switch 8814 chassis in a cabinet Switch 8814 17UConnecting Pgnd Wire Common grounding environment Connecting Pgnd Wire and Power CordOther grounding environment Ground the switch when ground bar is available Ground the switch via AC PE wire Connecting AC Power CordConnect AC power cord to the Switch Grounding PoE chassis Connecting PoE power cableInstall mounting ears onto the both sides of the switch Installing Fan TrayFan tray is hot swappable Contact take the fan tray out from the packing bag Lightning Protection BoxFasten the screw on top of the PoE lightning protection box Installing I/O modulesIntroduction Connecting Interface CablesConnecting console cable RJ-45 Signal Direction DB-25 DB-9AUX cable pinouts AUX cableConnecting Fiber Connecting AUX cableIntroduction to RJ-45 connector Connecting category-5 shielded cableCable Management Cable Routing RecommendationsIntertwinement or bending is allowed Cable bundling example Cable fixing example Cable bundle diameter mm Space between bundles mm Verifying InstallationInstallation checking list Tie-binding parametersSwitch Installation Environment Setting up Configuration EnvironmentSetting up System DebuggingVerifying Installation Before Powering Switch Powering and Booting the SwitchZbbtest System Debugging Troubleshooting PSU Switch Monitoring MaintenanceDescription of the LEDs on PSU Description of fan tray LEDs Indicator State descriptionReplacing AC PSU Hardware MaintenanceRemoving AC PSU Switch 8807 as example IndicatorRemove and install the AC PSU Installing AC PSU Switch 8807 as exampleInstalling the air filter of PSU Removing and cleaning the air filter of PSURequired tools Replacing and Cleaning Air Filter of ChassisRemoving and cleaning the air filter of chassis Installing the air filter of the chassisReplacing the Fan Tray Required tools Installing a ModuleRemoving a module Gently pull the module out of the slot along the guidesRecommended upgrade procedure Software UpgradeRequired cables Press Ctrl+B as prompted and the system will display Boot menuMain Menu Upgrading software through console port XModemSerial Submenu A Windows 98 operating system environment, you can performSend File dialog box Upgrading software through management Ethernet port TftpFiles using Tftp and to 0x0 if using FTP Upgrading software through management Ethernet port FTP Loading using FTP Load host program Remote and local loading using TftpInsufficient Flash memory Password LossSoftware Upgrade No response from fabric serial interface No configuration saving during I/O module rebootSwitch Monitoring and Maintenance Diagram of lightning arrester Lightning Protection SwitchInstallation procedure Installation Lightning Arrester for Network PortIs not well grounded yet Use the nylon ties to bundle the cables neatly Installation precautions
Related manuals
Manual 104 pages 36.87 Kb