3Com 8810, 8807, 8814 CF status LED, Status LEDs for I/O module, Gbps Switch Fabric LED Status

Page 20

20CHAPTER 1: PRODUCT OVERVIEW

Table 11 CF status LED

LED

Status

 

 

 

 

CFS

ON

The CF card is in position and is idle. You cannot remove the card.

 

Blinking

The CF card is in position and reading/writing data. You cannot remove

 

 

the card.

 

OFF

The CF card is out of position or offline (you can force the in-position CF

 

 

card to go offline using the appropriate background command). You can

 

 

remove/insert the card.

 

 

 

Status LEDs for I/O module

The 360 Gbps Switch Fabric module has 12 pairs of LEDs to indicate the operating status of 12 I/O module.

Table 12 Status LEDs for I/O module

LED

Status

 

 

 

 

RUN

ON

The module is faulty.

 

OFF

The module is faulty or out of position.

 

Blinking (1s)

The module is running normally.

 

Fast blinking (125 ms)

The module is booting or not registered successfully.

ALM

ON

The module has alarms.

 

OFF

The module has no alarms or is out of position.

0~5,

Indicate slots 0 through 5 and slots 8 through 13

8~13

 

 

 

 

 

Status LEDs for the 360 Gbps Switch Fabric module

You can learn the operating status of 360 Gbps Switch Fabric module by reading the SFS, ACT, ALM and RUN LEDs on it. The following table gives a summary of the four LEDs.

Table 13 Status LEDs for the 360 Gbps Switch Fabric module

360 Gbps Switch

 

 

 

Fabric LED

Status

 

 

 

 

 

SFS

ON

The switching fabric unit is active.

 

OFF

The switching fabric unit is standby.

RUN

Green

The 360 Gbps Switch Fabric module is faulty.

 

OFF

The 360 Gbps Switch Fabric module is faulty.

 

Green blinking

The 360 Gbps Switch Fabric module runs normally.

ALM

Red

The 360

Gbps Switch Fabric module has alarms.

 

OFF

The 360

Gbps Switch Fabric module has no alarms.

ACT

Green

The 360

Gbps Switch Fabric module is active.

 

OFF

The 360

Gbps Switch Fabric module is standby.

 

 

 

 

Image 20
Contents 3Com Switch 8800 Family 3Com Corporation Campus Drive Marlborough, MA USA United States Government LegendContents System Debugging About this Guide ConventionsProtocols that are used to interconnect LANs Lists icon conventions that are used throughout this guideSwitch Using the supported protocols and CLI commandsRelated Documentation8800s Product OverviewPreface 3Com Switch 8810 10-Slot Chassis 3Com Switch 8814 14-Slot Chassis Chassis and Slots Switch Switch 8807 slotsSwitch Switch 8810 slotsFunctions StructureEach Ethernet port can deliver up to 15.4 W to its PD AC Power SystemSpecifications Switch External PoE Power Rack 3C17509 PoE entry areaLabel Color State Abnormal reason Mbus IntroductionNormal Abnormal Fan tray panel of the Switch 8800 Family Role and functionPanel Gbps Switch FabricFabric Modules RS232/485 port specifications Compact Flash CF slotManagement Ports Status LEDs for the management 10Base-T/100Base-TX portReset button Console port specificationsAUX port specifications Status LEDsStatus LEDs for the 360 Gbps Switch Fabric module Gbps Switch Fabric LED StatusCF status LED Status LEDs for I/O moduleGbps Switch Fabric Technical specifications 720 Gbps Switch Fabric specificationsAUX port Status LEDs for the 720 Gbps Switch Fabric module Status LEDs for the 720 Gbps Switch Fabric module Technical specifications of the Switch 8800 FamilySoftware features of the Switch 8800 Family Software FeaturesSupported software features Lacp Software features of the Switch 8800 Family Product Overview O modules available to the Switch 8800 Family 3C17511 module specificationsApplication Modules Overview3C17512 module specifications 3C17512 2-port 10GBASE-X XFP ModulePanel and LEDs 3C17511 module panel Port LEDs on the 3C17511 module3C17513 module has two LEDs for each port on its panel Specifications3C17513 12-port 1000BASE-X SFP Module 3C17514 module specifications 3C17514 24-port 1000BASE-X SFP ModulePort LEDs on the 3C17513 module Panel and LEDs 3C17514 module panelPort LEDs on the 3C17516 module 3C17525 1-port 10GBASE-X Advanced Xenpak Module3C17516 module has one LED for each port on its panel 3C17526 module specifications 3C17526 4-port 10GBASE-X XFP ModulePanel and LEDs 3C17525 module panel Port LEDs on the 3C17525 module3C17527 module specifications 3C17527 2-port 10GBASE-X XFP Advanced ModulePanel and LEDs 3C17526 module panel 1000 Mbps optical port LEDs on the 3C17526 module3C17528 48port 10/100/1000 BASE-T RJ-45 Module 3C17528 module has one LED for each port on its panelPanel and LEDs 3C17530 module panel 3C17530 24-port 1000BASE-X SFP Advanced Module3C17531 24-port 10/100/1000BASE-T Advanced Module 3C17532 module specifications 3C17531 module has one LED for each port on its panelPanel and LEDs 3C17531 module panel Port LEDs on the 3C17531 modulePanel and LEDs 3C17533 module panel 3C17533 24-port 1000BASE-X SFP IPv6 Module3C17532 module has one LED for each port on their panel 3C17534 module specifications 3C17536 module specifications3C17534 24-port 10/100/1000BASE-T IPv6 Module 3C17536 4-port 10GBASE-X XFP Quad IPv6 Module3C17538 module specifications 3C17538 48-port 1000BASE-X SFP IPv6 ModulePanel and LEDs 3C17536 module panel 1000 Mbps optical port LEDs on the 3C17536 moduleTechnical specifications for the 3C17542 Front panelPanel and LEDs 3C17538 module panel Port LEDs on the 3C17538 moduleTechnical specifications for the 3C17546 Technical specifications for the 3CR1754766Available cables Status LEDs on the 3C17546Technical specifications for the 3C17548 Status LEDs on the 3CR1754766Transceivers Documents the 3Com Switch 8800 Family transceiversTransceiver Specifications Switch 8800 Port Switch 8800 Available ModulesDensities Description Max PortInstallation Preparation SafetyGeneral Safety RecommendationsInstallation Preparation Limitation on dust content in equipment room Mechanical active material Unit ContentHarmful gas limits in an equipment room Gas Average mg/m3 Max. mg/m3Installation Tools Power Supply Requirements Space RequirementsRequired installation tools MeasureInstallation Flow Switch InstallationConfirming Installation Preparation Mounting the Switch User-Supplied Cabinet One Switch 8807 chassis in a cabinetTwo Switch 8807 chassis in a cabinet One Switch 8807 chassis in a cabinet Switch 8807 11UOne Switch 8810 chassis in a cabinet Two Switch 8807 chassis in a cabinet Switch 8807 11UOne Switch 8814 chassis in a cabinet One Switch 8810 chassis in a cabinet Switch 8810 14UOne Switch 8814 chassis in a cabinet Switch 8814 17U CabinetOther grounding environment Connecting Pgnd Wire and Power CordConnecting Pgnd Wire Common grounding environment Ground the switch when ground bar is available Connecting AC Power Cord Ground the switch via AC PE wireConnect AC power cord to the Switch Connecting PoE power cable Grounding PoE chassisFan tray is hot swappable Installing Fan TrayInstall mounting ears onto the both sides of the switch Lightning Protection Box Contact take the fan tray out from the packing bagInstalling I/O modules Fasten the screw on top of the PoE lightning protection boxConnecting Interface Cables Connecting console cableRJ-45 Signal Direction DB-25 DB-9 IntroductionAUX cable AUX cable pinoutsConnecting AUX cable Introduction to RJ-45 connectorConnecting category-5 shielded cable Connecting FiberIntertwinement or bending is allowed Cable Routing RecommendationsCable Management Cable bundling example Cable fixing example Verifying Installation Installation checking listTie-binding parameters Cable bundle diameter mm Space between bundles mmSwitch Installation Setting up Configuration Environment Setting upSystem Debugging EnvironmentPowering and Booting the Switch Verifying Installation Before Powering SwitchZbbtest System Debugging Description of the LEDs on PSU Switch Monitoring MaintenanceTroubleshooting PSU Indicator State description Description of fan tray LEDsHardware Maintenance Removing AC PSU Switch 8807 as exampleIndicator Replacing AC PSUInstalling AC PSU Switch 8807 as example Remove and install the AC PSURemoving and cleaning the air filter of PSU Installing the air filter of PSUReplacing and Cleaning Air Filter of Chassis Removing and cleaning the air filter of chassisInstalling the air filter of the chassis Required toolsInstalling a Module Removing a moduleGently pull the module out of the slot along the guides Replacing the Fan Tray Required toolsRequired cables Software UpgradeRecommended upgrade procedure Boot menu Press Ctrl+B as prompted and the system will displayUpgrading software through console port XModem Main MenuA Windows 98 operating system environment, you can perform Serial SubmenuUpgrading software through management Ethernet port Tftp Send File dialog boxFiles using Tftp and to 0x0 if using FTP Upgrading software through management Ethernet port FTP Loading using FTP Remote and local loading using Tftp Load host programPassword Loss Software Upgrade No response from fabric serial interfaceNo configuration saving during I/O module reboot Insufficient Flash memorySwitch Monitoring and Maintenance Lightning Protection Switch Diagram of lightning arresterIs not well grounded yet Installation Lightning Arrester for Network PortInstallation procedure Installation precautions Use the nylon ties to bundle the cables neatly
Related manuals
Manual 104 pages 36.87 Kb

8810, 8814, 8807 specifications

The 3Com 8814, 8810, and 8807 are renowned products from the networking giant 3Com, which played a significant role in the evolution of networking technology in the early 1990s. These devices were instrumental during a time when organizations were transitioning from traditional communication systems to more sophisticated networking solutions.

The 3Com 8814 is a multi-port networking hub designed for small to medium-sized businesses. One of its main features includes a 10Base-T Ethernet capability, allowing for fast and reliable connectivity among various devices within a local area network (LAN). The 8814 supports up to 14 connections, providing scalability for growing businesses. The hub’s ease of use is notable; it features a plug-and-play design, which aids in quick setup without requiring extensive configuration. This plug-and-play functionality, alongside its robust physical and electrical performance, made the 8814 an appealing choice for organizations looking to enhance their networking infrastructure without significant investment.

Moving on to the 3Com 8810, this device is labeled as an intelligent network switch and ushered in advancements in network management and performance. A critical element of the 8810 is its ability to support both 10/100Base-T Ethernet connections, effectively allowing mixed-speed environments. Its built-in management features, enabled by 3Com's networking technologies, offered users the ability to monitor traffic flow, manage bandwidth allocation, and configure network settings through a user-friendly interface. This switch also incorporated advanced features like VLAN support, increasing security and segmentation within networks, which proved invaluable for sophisticated networking environments.

Lastly, the 3Com 8807 represents a more versatile and high-performance switch option suited for larger networks. This model features a stackable design that allows for a broader range of scalability and redundancy. It supports both fast Ethernet and Gigabit Ethernet, ensuring that organizations can expand their network speeds as needed. The 8807 includes features for enhanced fault tolerance and link aggregation, which bolsters reliability and performance under heavy traffic loads. Its integration with 3Com's Network Management Software provided administrators with unprecedented control over their networks, empowering them to optimize performance and troubleshoot issues effectively.

Overall, the 3Com 8814, 8810, and 8807 exemplified the company's commitment to innovation in networking technology, providing businesses with the tools necessary to develop efficient, scalable, and reliable network infrastructures. Each of these devices played a crucial role in shaping the landscape of networking, emphasizing ease of use, management capabilities, and performance.