3Com 8814 Available cables, Technical specifications for the 3C17546, Status LEDs on the 3C17546

Page 43

Application Modules 43

3C17546 Firewall Application Module

Technical specifications

The 3C17546 Firewall Application Module provides eight Gigabit SFP/LC optical ports.

Table 59 Technical specifications for the 3C17546

Item

Specifications

 

 

CPU

BCM1250

Boot ROM

512 KB

SDRAM

1 Gbps

Physical dimensions (W x D)

366.7 x 340 mm (14.4 x 13.4 in.)

 

 

Front panel

Figure 29 Front panel of the 3C17546

The 3C17546 provides eight 1000Base-X ports, one Console port, one AUX port, three 10/100Base-TX ports and four status LEDs (ATTACK, ACT, ALM and RUN) from left to right on the front panel.

Table 60 Status LEDs on the 3C17546

LED

Color

Status

Meaning

 

 

 

 

ATTACK

Red

OFF

The module is not attacked.

 

 

ON

The module is attacked.

ACT

Green

OFF

The module is in standby mode.

 

 

Blinking

The module is in active mode.

ALM

Red

OFF

There is no link alarm.

 

 

ON

There is a link alarm.

RUN

Green

OFF

The module is faulty.

 

 

Blinking

The module operates normally.

 

 

 

 

3CR1754766 IPsec Module

Available cables

Table 64 on page 45 lists the available SFP modules and cable types for the 1000BASE-X SFP ports.

Technical specifications

The 3CR1754766 IPsec Module provides eight Gigabit SFP optical ports.

Table 61 Technical specifications for the 3CR1754766

Item

Specifications

 

 

CPU

BCM1250

Boot ROM

512 KB

Image 43
Contents 3Com Switch 8800 Family United States Government Legend 3Com Corporation Campus Drive Marlborough, MA USAContents System Debugging Lists icon conventions that are used throughout this guide About this GuideConventions Protocols that are used to interconnect LANsDocumentation SwitchUsing the supported protocols and CLI commands RelatedPreface Product Overview8800s 3Com Switch 8810 10-Slot Chassis 3Com Switch 8814 14-Slot Chassis Switch 8807 slots Chassis and Slots SwitchSwitch 8810 slots SwitchStructure FunctionsSpecifications Switch AC Power SystemEach Ethernet port can deliver up to 15.4 W to its PD PoE entry area External PoE Power Rack 3C17509Normal Abnormal Mbus IntroductionLabel Color State Abnormal reason Role and function Fan tray panel of the Switch 8800 FamilyFabric Modules Gbps Switch FabricPanel Status LEDs for the management 10Base-T/100Base-TX port RS232/485 port specificationsCompact Flash CF slot Management PortsStatus LEDs Reset buttonConsole port specifications AUX port specificationsStatus LEDs for I/O module Status LEDs for the 360 Gbps Switch Fabric moduleGbps Switch Fabric LED Status CF status LED720 Gbps Switch Fabric specifications Gbps Switch Fabric Technical specificationsAUX port Status LEDs for the 720 Gbps Switch Fabric module Technical specifications of the Switch 8800 Family Status LEDs for the 720 Gbps Switch Fabric moduleSupported software features Software FeaturesSoftware features of the Switch 8800 Family Lacp Software features of the Switch 8800 Family Product Overview Overview O modules available to the Switch 8800 Family3C17511 module specifications Application ModulesPort LEDs on the 3C17511 module 3C17512 module specifications3C17512 2-port 10GBASE-X XFP Module Panel and LEDs 3C17511 module panel3C17513 12-port 1000BASE-X SFP Module Specifications3C17513 module has two LEDs for each port on its panel Panel and LEDs 3C17514 module panel 3C17514 module specifications3C17514 24-port 1000BASE-X SFP Module Port LEDs on the 3C17513 module3C17516 module has one LED for each port on its panel 3C17525 1-port 10GBASE-X Advanced Xenpak ModulePort LEDs on the 3C17516 module Port LEDs on the 3C17525 module 3C17526 module specifications3C17526 4-port 10GBASE-X XFP Module Panel and LEDs 3C17525 module panel1000 Mbps optical port LEDs on the 3C17526 module 3C17527 module specifications3C17527 2-port 10GBASE-X XFP Advanced Module Panel and LEDs 3C17526 module panel3C17528 module has one LED for each port on its panel 3C17528 48port 10/100/1000 BASE-T RJ-45 Module3C17531 24-port 10/100/1000BASE-T Advanced Module 3C17530 24-port 1000BASE-X SFP Advanced ModulePanel and LEDs 3C17530 module panel Port LEDs on the 3C17531 module 3C17532 module specifications3C17531 module has one LED for each port on its panel Panel and LEDs 3C17531 module panel3C17532 module has one LED for each port on their panel 3C17533 24-port 1000BASE-X SFP IPv6 ModulePanel and LEDs 3C17533 module panel 3C17536 4-port 10GBASE-X XFP Quad IPv6 Module 3C17534 module specifications 3C17536 module specifications 3C17534 24-port 10/100/1000BASE-T IPv6 Module1000 Mbps optical port LEDs on the 3C17536 module 3C17538 module specifications3C17538 48-port 1000BASE-X SFP IPv6 Module Panel and LEDs 3C17536 module panelPort LEDs on the 3C17538 module Technical specifications for the 3C17542Front panel Panel and LEDs 3C17538 module panelStatus LEDs on the 3C17546 Technical specifications for the 3C17546Technical specifications for the 3CR1754766 Available cablesStatus LEDs on the 3CR1754766 Technical specifications for the 3C17548Transceiver Specifications Documents the 3Com Switch 8800 Family transceiversTransceivers Description Max Port Switch 8800 PortSwitch 8800 Available Modules DensitiesRecommendations Installation PreparationSafety General SafetyInstallation Preparation Gas Average mg/m3 Max. mg/m3 Limitation on dust content in equipment roomMechanical active material Unit Content Harmful gas limits in an equipment roomMeasure Installation ToolsPower Supply Requirements Space Requirements Required installation toolsConfirming Installation Preparation Switch InstallationInstallation Flow One Switch 8807 chassis in a cabinet Mounting the Switch User-Supplied CabinetOne Switch 8807 chassis in a cabinet Switch 8807 11U Two Switch 8807 chassis in a cabinetTwo Switch 8807 chassis in a cabinet Switch 8807 11U One Switch 8810 chassis in a cabinetOne Switch 8810 chassis in a cabinet Switch 8810 14U One Switch 8814 chassis in a cabinetCabinet One Switch 8814 chassis in a cabinet Switch 8814 17UConnecting Pgnd Wire Common grounding environment Connecting Pgnd Wire and Power CordOther grounding environment Ground the switch when ground bar is available Ground the switch via AC PE wire Connecting AC Power CordConnect AC power cord to the Switch Grounding PoE chassis Connecting PoE power cableInstall mounting ears onto the both sides of the switch Installing Fan TrayFan tray is hot swappable Contact take the fan tray out from the packing bag Lightning Protection BoxFasten the screw on top of the PoE lightning protection box Installing I/O modulesIntroduction Connecting Interface CablesConnecting console cable RJ-45 Signal Direction DB-25 DB-9AUX cable pinouts AUX cableConnecting Fiber Connecting AUX cableIntroduction to RJ-45 connector Connecting category-5 shielded cableCable Management Cable Routing RecommendationsIntertwinement or bending is allowed Cable bundling example Cable fixing example Cable bundle diameter mm Space between bundles mm Verifying InstallationInstallation checking list Tie-binding parametersSwitch Installation Environment Setting up Configuration EnvironmentSetting up System DebuggingVerifying Installation Before Powering Switch Powering and Booting the SwitchZbbtest System Debugging Troubleshooting PSU Switch Monitoring MaintenanceDescription of the LEDs on PSU Description of fan tray LEDs Indicator State descriptionReplacing AC PSU Hardware MaintenanceRemoving AC PSU Switch 8807 as example IndicatorRemove and install the AC PSU Installing AC PSU Switch 8807 as exampleInstalling the air filter of PSU Removing and cleaning the air filter of PSURequired tools Replacing and Cleaning Air Filter of ChassisRemoving and cleaning the air filter of chassis Installing the air filter of the chassisReplacing the Fan Tray Required tools Installing a ModuleRemoving a module Gently pull the module out of the slot along the guidesRecommended upgrade procedure Software UpgradeRequired cables Press Ctrl+B as prompted and the system will display Boot menuMain Menu Upgrading software through console port XModemSerial Submenu A Windows 98 operating system environment, you can performSend File dialog box Upgrading software through management Ethernet port TftpFiles using Tftp and to 0x0 if using FTP Upgrading software through management Ethernet port FTP Loading using FTP Load host program Remote and local loading using TftpInsufficient Flash memory Password LossSoftware Upgrade No response from fabric serial interface No configuration saving during I/O module rebootSwitch Monitoring and Maintenance Diagram of lightning arrester Lightning Protection SwitchInstallation procedure Installation Lightning Arrester for Network PortIs not well grounded yet Use the nylon ties to bundle the cables neatly Installation precautions
Related manuals
Manual 104 pages 36.87 Kb