2.Remove the blank.

CAUTION: For best cooling practices, do not operate the enclosure for extended periods with more than one component or blank removed. When removing an active component, replace it with a blank.

To replace the component, slide the component into the bay until it locks into place.

Interconnect switch or Pass-Thru module

CAUTION: This procedure provides instructions for replacement of a failed part only. To change the configuration of components, see the appropriate HP BladeSystem c-Class enclosure setup and installation guide.

To remove the component:

CAUTION: To prevent data loss, redirect network activity or be sure that all critical network activity has stopped before removing the interconnect module.

IMPORTANT: A port must be occupied by an SFP transceiver or an SFP dust cover at all times.

1.Disconnect all cables from the component.

2.Press the release tab.

3.Open the handle.

Removal and replacement procedures 38