3Com 1000BASE-SX quick start ESD Safety Information

Page 4

42-PORT 1000BASE-SXAND 2-PORT 1000BASE-LX GIGABIT ETHERNET INTERFACE MODULES QUICK START GUIDE

ESD Safety Information

Electrostatic discharge (ESD) can damage components of the module. ESD, which occurs when a GEN Interface Module is improperly handled, can cause complete or intermittent failures.

CAUTION: To prevent ESD-related damage:

Always wear an ESD wrist strap (not provided) when you handle a GEN Interface Module, ensuring that the strap makes good skin contact.

Keep the GEN Interface Module in its antistatic bag until you are ready to install it.

Handling Precautions When you handle a GEN Interface Module, follow these precautions:

Always handle the module by its front panel only.

Do not touch the components, pins, leads, or solder connections.

Do not twist or otherwise force the module into the chassis when you insert it into the module slot guides.

Before you push the module into the chassis, make sure that the module ejector handles are open.

To slide the module into the 16-slot chassis, match the upper and lower module guides; in the 7-slot chassis, match the left and right module guides.

Unpacking Use the following procedure when you unpack a GEN Interface Instructions Module:

1Verify that the GEN Interface Module is the correct product by matching the order number that is listed on the shipping box label to the order number that is listed on your sales invoice (3CB9LG2MC or 3CB9LG2SC).

2Remove the module, in its antistatic bag, from the shipping box.

3Ensure that the box also contains:

CoreBuilder 9000 GEN Switch Fabric and GEN Interface Modules Release Notes

2-Port 1000BASE-SX and 2-Port 1000BASE-LX Gigabit Ethernet Interface Modules Quick Start Guide for the CoreBuilder 9000 Enterprise Switch (this guide)

Image 4
Contents For the CoreBuilder 9000 Enterprise Switch Front Panels of the GEN Interface Modules Ejector handleFDA Class 1 Laser Device ESD Safety Information Page Page Page By this module By this module Reserved for an SFM Not applicableReserved for an SFM Not applicable Interface Module GEN Interface Module Spring-loaded ScrewsSpring-loaded Screw Interface ModulePage Port is cabled but the switch fabric Link is disabled or port is not cabledPort is receiving or transmitting PacketsConnect slot.1 1000BASE-SX 3CB9LG2MC Module Cabling Requirements 1000BASE-LX 3CB9LG2SC Module Cabling RequirementsUp to 500 m 1,640 ft Up to 550 m 1,804 ftPhysical Specifications Power SpecificationsEnvironmental Requirements Regulatory ComplianceRelated CoreBuilder Documents Page Page Hardware Year 2000 WarrantySoftware Obtaining Warranty Service Warranties ExclusiveLimitation of Liability DisclaimerEMC Directive Statement Emissions Compliance Statements for Class a ProductsLOW Voltage Directive Statement General Approval Statement for UK Australian EMC Frameworks Statement
Related manuals
Manual 12 pages 20.15 Kb

1000BASE-SX specifications

The 3Com 1000BASE-SX is a pivotal technology in the fiber-optic networking landscape, offering high-speed data transfer capabilities that cater to various networking needs. As part of the Gigabit Ethernet standards set by IEEE 802.3, 1000BASE-SX is specifically designed for short-range applications, typically within local area networks (LANs). It utilizes multimode fiber optic cables to deliver data at speeds of up to 1 Gbps, making it ideal for environments that require efficient and fast data exchange.

One of the main features of 3Com 1000BASE-SX is its reliance on multimode fiber optic cables, which allows for the transmission of light signals with multiple paths, effectively enhancing bandwidth and distance capabilities. This technology supports distance ranges of up to 550 meters on OM2 multimode fiber and up to 300 meters on OM1 fiber, making it suitable for office buildings or campuses where networking equipment is located relatively close to one another. Given its limited range, 1000BASE-SX is best utilized in scenarios where high performance is necessary without the requirements for long-distance connections.

Another significant characteristic of the 3Com 1000BASE-SX technology is its wavelength. Operating at an 850 nm wavelength, the system utilizes vertical-cavity surface-emitting lasers (VCSELs) as a light source. VCSEL technology is favored for its efficiency and ability to provide low-cost, high-density connections, which aligns with the growing demand for robust networking solutions in modern enterprise environments.

In terms of compatibility and ease of integration, 3Com 1000BASE-SX interfaces seamlessly with Ethernet standards while also supporting various switching technologies. This versatility facilitates both the upgrade of existing networks and the construction of new, high-performance network infrastructures. Furthermore, it is backward-compatible with older Ethernet standards, allowing organizations to gradually transition to Gigabit Ethernet without the need for extensive infrastructure overhauls.

Lastly, 3Com’s adherence to industry standards ensures reliability and performance consistency across devices manufactured by different vendors, promoting interoperability. With an increasing reliance on data and the necessity for faster networking solutions, the 3Com 1000BASE-SX remains a significant choice for enterprises striving for efficiency in data traffic management and enhancing their overall network capabilities. Whether for corporate offices, educational institutions, or data centers, 3Com 1000BASE-SX offers a robust solution for the challenges of modern networking complexities.