Riverstone Networks RS 2100 manual Setting UP Snmp, Setting the Community string

Page 55

RS 2100 Initial Configuration

Setting Up SNMP

4.6SETTING UP SNMP

To use SNMP to manage the RS 2100, you need to set up an SNMP community and specifying the IP address of the target host for SNMP traps. Otherwise, the RS 2100’s SNMP agent runs in local trap process mode, unless disabled using the snmp stop command.

For additional information about configuring and using SNMP, see the Riverstone RS Switch Router User Guide.

4.6.1Setting the Community string

Use the following procedure to add the SNMP community string, specify the target host for traps, and the trap interface.

1.Ensure that you are in Enable mode by entering the enable command in the CLI.

2.Ensure that you are in Configure mode by entering the configure command in the CLI.

3.Use the following commands to add an SNMP community string and set a target host IP address for the traps:

rs(config)#snmp set community <community-name>privilege readread-write

rs(config)#snmp set target <IP-addr>community <community-name>status enabledisable

Note If the IP address of the trap target is more than one hop away from the RS 2100, configure the RS with a static route to the target. If the RS 2100 is rebooted, the static route allows a cold start trap to be sent to the trap target. Without a static route, the cold-start trap is lost while the routing protocols are converging.

4.Use the save startup command to activate the commands entered in the previous steps. Here is an example of the commands and output for configuring SNMP and saving the changes.

rs# config

rs(config)# snmp set community public privilege read-write

rs(config)# snmp set target 16.50.11.12 community public status enable

rs(config)# save startup

Are you sure you want to overwrite the Startup configuration [no]? yes

There are non-committed configuration changes. Do you want to make these changes active and then save everything to Startup [yes]? yes

%CONFIG-I-SAVED, 2001-09-02 21:53:54 %GATED-I-RECONFIGDONE, Routing configuration changes completed (pid 0x809eab20).

configuration saved to Startup configuration. rs(config)#

Riverstone Networks RS 2100 Switch Router Getting Started Guide 4-15

Image 55
Contents Rev B RS 2100 Switch Router Getting Started GuideCopyright Notices EN 61000-3-3 EN 50082-1, AS/NZS 3548 Vcci This product complies with the followingUL 1950 CSA C22.2, No 73/23/EEC EN 60950 IEC FCC Part 15 CSA C108.8 89/336/EEC EN 55022 ENIndustry Canada Compliance Statement Vcci Compliance Statement Equipment Attachment Limitations Notice Page Riverstone NETWORKS, INC Title and Proprietary Rights General Page Riverstone Standard Warranty Page EC Directive 73/23/EEC 89/336/EEC73/23/EEC EC Directive 89/336/EECTable of Contents Troubleshooting Index List of Figures Page List of Tables Page Related Documentation HOW to USE this GuideFor Information About See Related Documentation Functional Layer Terminology Feature Specification SpecificationsRouting Software OverviewBridging Port and Protocol VLANsIP Routing Quality of Service Layer-4 SwitchingSecurity Statistics Web Hosting FeaturesManagement Platforms LED Label Description Hardware OverviewChassis External ControlsInput voltage Input current maximum Motherboard Features100-125 VAC 200-240 VAC Fans Port type SpecificationGigabit Ports Gigabit ports use the following LEDs LEDsPage Preventing Injury Safety ConsiderationsPreventing Equipment Damage Verifying Your Shipment Hardware SpecificationsInstalling the Hardware Specification MeasurementInstalling the Chassis Attaching Cables to the Management Ports Connecting the Serial Management CableTXD transmit data RXD receive dataa Unused Signal RS 2100 port Pin Signal management console portRXD receive data TXD transmit data Unused Powering on the RS RS 2100 Initial ConfigurationPress Return to activate console Here is a partial exampleRS 2100 Initial Configuration You are in Boot mode, the command prompt is rs-boot Starting the Command Line InterfaceCLI Access Modes Access Mode DescriptionKey sequence Command Basic Line Editing CommandsActivating the Configuration Commands in the Scratchpad Configuration Changes and Saving the Configuration FileFile Descriptions Copy active to startup Viewing the Current Configuration Here is an example Setting the Basic System InformationSet name rs Copy active to startup Rs# system show active-config Setting UP PasswordsEnter the following line to reboot the RS If You Forget Your PasswordsSetting Up Passwords RS 2100 Initial Configuration Setting the Community string Setting UP SnmpApplying ACLs to Snmp Improving Snmp SecurityLayer System Related Enterprise Supported MIBsEnter the following command to add the DNS server to the RS Setting the DNS Domain Name and AddressRs# system show dns Fatal Setting the Syslog ParametersMessage Type Description Message Type ExampleSetting the Syslog Parameters Page Upgrading System Image Software Managing RS 2100 SoftwareRs# system image list Use the system image list command to verify the changeUpgrading Boot Prom Software Upgrading Boot Prom Software Loading Image Software from a Tftp Server Loading Software from the NetworkEnter the set command to view the changes Here is an example Loading Image Software from a BootP/TFTP Server Loading Software from the Network If you experience this difficulty Try this remedy Appendix a TroubleshootingSettings If you have already performed this procedure, makeDefault domain If you have already performed this procedure, typeAdding new image to internal flash Annotations in configuration filesElectrostatic discharge ESD If you forget your passwordIgmp Syslog Viewing active configuration

RS 2100 specifications

Riverstone Networks RS 2100 is a versatile networking solution tailored for service providers and enterprises. Designed to facilitate seamless data, voice, and video services, the RS 2100 presents a robust platform that integrates both hardware and software capabilities. This device stands out in the realm of advanced routing and switching technologies, offering extensive features that cater to a wide array of connectivity needs.

One of the key features of the RS 2100 is its ability to support high-speed interfaces. With multiple Gigabit Ethernet ports, the device ensures substantial bandwidth to handle growing data traffic demands. This makes it an excellent choice for organizations looking to future-proof their networks. Additionally, the RS 2100 supports aggregation of different types of traffic flows, allowing for efficient resource utilization and enhanced performance.

The RS 2100 also boasts advanced Quality of Service (QoS) capabilities, which are essential for prioritizing different types of traffic. This is particularly important for applications that require consistent performance, such as VoIP calls or video streaming. By enabling service providers to guarantee bandwidth for critical applications, the RS 2100 enhances user experience and customer satisfaction.

Security is another critical aspect of the RS 2100, featuring multiple layers of protection against various cyber threats. With support for robust firewall functionalities and various VPN protocols, the device ensures that sensitive data remains secure, thereby fortifying the network against potential attacks.

In terms of scalability, the RS 2100 is highly adaptable. Organizations can easily expand their network capabilities as demands grow, thanks to its flexible architecture. This scalability ensures that users can comfortably accommodate increasing user counts and traffic levels over time without necessitating significant infrastructure changes.

The RS 2100 also integrates seamlessly with existing IT infrastructures. Utilizing standard protocols and interfaces, it simplifies deployment and management processes, allowing organizations to easily incorporate it into their current systems. Overall, Riverstone Networks RS 2100 is a powerful and efficient networking solution, equipped with the features needed to support modern communication demands, ensuring reliability and performance across diverse applications. As businesses and service providers continue to evolve, the RS 2100 serves as a trusted partner in navigating the complexities of networking and connectivity.