Psiber Data Systems RF3D manual Manual

Page 26

manual

The array, or list of values, which follows contains phi values (angle measures in de- grees) for 72 data points at 2.4 GHz. If you use a different number of data points, replace the “72” in this line with the number of data points you want to define.

<SOAP-ENC:Array id=“ref-6“ SOAP-ENC:arrayType=“xsd:float[72]“> <item>-180</item>

<item>-175</item> <item>-170</item>

.

.

.

<item>165</item>

<item>170</item>

<item>175</item> </SOAP-ENC:Array>

The next array, with the attribute id=”ref-7”, contains theta values (angle measures in degrees) for 72 data points at 2.4 GHz.

<SOAP-ENC:Array id=“ref-7“ SOAP-ENC:arrayType=“xsd:float[72]“> <item>-90</item>

<item>-85</item> <item>-80</item>

.

.

.

<item>255</item>

<item>260</item>

<item>265</item> </SOAP-ENC:Array>

The next array, with the attribute id=”ref-8”, contains gain values in dBi for the values of phi listed above, representing 72 data points at 2.4 GHz.

<SOAP-ENC:Array id=“ref-8“ SOAP-ENC:arrayType=“xsd:float[72]“> <item>-2.381</item>

<item>-2.399</item> <item>-2.388</item>

.

.

.

<item>-2.005</item> <item>-2.175</item> <item>-2.303</item> </SOAP-ENC:Array>

25

Image 26
Contents Manual Contents Introduction Installation and Activation PC 1.1PC Hardware RequirementsManual Standardization in Wireless Networking Fundamentals of Wireless Network PlanningProduct Updates Ieee 802.11b SpecificationIeee 802.11h Specification Ieee 802.11g SpecificationIeee 802.11a Specification Frequencies and ChannelsManual Cellular Structure of a Wireless Network Antennas Attenuation Theoretical Throughput Rates1Importing Building Plans RF3D User InterfaceRedundancy Manual Manual Toolbox Drawing and Selecting Elements Simulation TabManual Advanced Settings Planning Wireless NetworksAccess Point Tab What Application Is Intended?Entering Environmental Factors Positioning Access Points Manual Optimizing Wireless Networks Advanced Settings Editing Wall and Floor LibrariesEditing the Access Point/Antenna Library IsZIsotropic24GHztrue/IsZIsotropic24GHz Manual All other lines in the file must remain unchanged Options and Settings Floors with OpeningsSplit-Level Buildings Appendix a The Antenna Library Antenna LibraryManual Horizontal section of a/h Net Vertical section of a/h Net Manual Manual Manual Appendix B The Wall and Floor Library List of wall & floor materials measurement unit feetMetallic Drop Ceiling 30/45dB Floor 24,0 36,0 List of wall & floor materials measurement unit meter Appendix C Table of Colors Color KnownColorManual Anhang D Eula If YOU do not AGREE, do not USE this SoftwareLimitations on END User Rights DefinitionsEND User Rights and USE COPYRIGHT, Intellectual Property Ownership Commencement & TerminationNo Other Obligations Limitation of LiabilityTechnical Support Export ControlGermany Applicable LAW & General ProvisionsPsiber USA