Powerware FE/QFE 500VA manual Belangrijke Veiligheidsinstructies, V a R S E L, V a a R

Page 11

A D V A R S E L

:Batterier kan udgøre en fare for elektrisk stød eller forbrændinger forårsaget af høj kortslutningsspænding. De korrekte forholdsregler bør overholdes.

:Korrekt bortskaffelse af batterier er påkrævet. Overhold gældende lokale regler for bortskaffelsesprocedurer.

:Skaf dig aldrig af med batterierne ved at brænde dem. Batterierne kan eksplodere ved åben ild.

Belangrijke Veiligheidsinstructies

BELANGRIJKE VEILIGHEIDSINSTRUCTIES

BEWAAR DEZE INSTRUCTIES

DEZE HANDLEIDING BEVAT BELANGRIJKE

VEILIGHEIDSINSTRUCTIES

G E V A A R

Deze UPS bevat LEVENSGEVAARLIJKE ELEKTRISCHE SPANNING. Alle reparaties en onderhoud dienen UITSLUITEND DOOR ERKEND SERVICEPERSONEEL te worden uitgevoerd. Er bevinden zich GEEN ONDERDELEN in de UPS die DOOR DE GEBRUIKER kunnen worden GEREPAREERD.

W A A R S C H U W I N G

:Deze UPS bevat zijn eigen energiebron (batterijen). De uitgangsaansluitingen kunnen onder spanning staan wanneer de UPS niet op een wisselstroom voeding is aangesloten.

:Verwijder de ingangsnoer niet of haal de stekker van de ingangsnoer er niet uit terwijl de UPS aan staat. Hierdoor zou de UPS en uw aangesloten apparatuur geen aardebeveiliging meer hebben.

:Teneinde de kans op brand of elektrische schok te verminderen dient deze UPS in een gebouw met temperatuur- en vochtigheidregeling te worden geïnstalleerd, waar geen geleidende verontreinigingen aanwezig zijn. De omgevingstemperatuur mag 40°C niet overschrijden. Niet gebruiken in de buurt van water of bij zeer hoge vochtigheid (max. 95%).

:Om aan de internationale normen en bedradingsvoorschriften te voldoen mag de gehele apparatuur die op de uitgang van deze UPS is aangesloten, geen aardlekstroom van meer dan 1,5 milliampère hebben.

Powerware® FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com

5

Image 11
Contents Powerware Ferrups FE/QFE UPS Page Powerware Ferrups FE/QFE UPS For Users in Germany FCC Part ICES-003Table of Contents Page Introduction Plug-Receptacle InstallationHardwired Installation 7TII -18kVA User’s Guide R N I N G Safety WarningsP O R T a N T S a F E T Y I N S T R U C T I O N S N G E RR E SikkerhedsanvisningerU T I O N A R S C H U W I N G Belangrijke VeiligheidsinstructiesV a R S E L V a a RR O I T U S Tarkeita TurvaohjeitaG E L E T A R aR O Consignes de sécuritéH T U N G SicherheitswarnungenR N U N G „Ò·Ûfl· C›„ÈÛÙ.ÃÁ˜ÒÁÙÈÏÔfi95%ÔÈÂflÙÂUPSÍÔÌÙ‹ÛÂÌÂÒ¸fi V E R T E N Z a Avvisi di sicurezzaR I C O L O R L I G Viktig SikkerhetsinformasionT E N Z I O N E V E R T Ê N C I a Regulamentos de SegurançaR S I K T I G I D a D OÐåäóïðåæäåíèå Ïðåäóïðåæäåíèÿ ïî ìåðàì áåçîïàñíîñòèR I G O ÎïàñíîV E R T E N C I a Advertencias de SeguridadÑòîðîæíî L I G R OR a SäkerhetsföreskrifterE C a U C I Ó N K T I G T Ferrups FE/QFE 500 VA-3.1 kVA Dimensions SetupDimensions Battery Cabinet Dimensions Ferrups FE/QFE 4.3-18 kVA DimensionsEquipment Clearances Clearances for the UPS and Battery CabinetsLocation Requirements Installation and Service ClearancesStorage and Operating Environment Page Electrical Installation Bypass Switch Positions Bypass SwitchesInternal Bypass Switch Specifications External Bypass Switch SpecificationsTypical Hardwired Installation with External Bypass Switch Typical Hardwired Installation with Internal Bypass Switch Page External Bypass Switch Wiring Diagrams External Bypass Switch Installation220 V q IGW W u q Recommended Wire SizesFE or QFE 4.3-18 kVA FE or QFE 500 VA-3.1 kVAExternal Bypass Switch Terminal Strip Labels Installation Wiring Diagrams for External Bypass Switches Page For 220 Vac, use only a BBM switch For 208 Vac, use only a BBM switch GBB tU-1.4 kVA KVA Standard 15A 50 Hz 220, 230, or 240 Vac Input and Output 60 Hz 120 Vac Input 120 Vac Output DBJ t DFB t CB U For FE 60 Hz 220 Vac, use only a BBM switch Page Internal Bypass Switch Wiring Diagrams Internal Bypass Switch InstallationFORU.S.INSTALLATIONS,150AREADTHISIMPORTANTNOTE Internal Bypass Switch BPI Terminal Strip Label Installation Wiring Diagrams for Internal Bypass Switches 60 Hz 120 Vac Input 120 Vac Output For 208 Vac, use only a BBM switch CB U For FE 60 Hz 220 Vac, use only a BBM switch Electrician must take these precautions Battery Cabinet InstallationBefore Installing the Batteries Nominal DC Battery Voltage Installing and Connecting the Batteries WUVflbr dpmsla Never install the batteries in an air-tight enclosure Battery Torque Value Modified Square Torque Battery Terminal TypesFEONorQFEposition4.318kVA Nominal Battery Voltage Replacing the Batteries Recycling the Used Battery Phase Check Internal Bypass Switch External Bypass Switch AC to UPS Load to AC Line Input Vac Q 2Vnb7BC3 7TII -18 kVA User’s Guide

FE/QFE 500VA specifications

The Powerware FE/QFE 500VA is a compact and efficient uninterruptible power supply (UPS) designed to provide reliable power protection for critical electronic equipment. This model is particularly well-suited for small servers, workstations, and networking hardware, ensuring operational continuity in the event of power disturbances, such as surges, brownouts, and outages.

One of the key features of the Powerware FE/QFE 500VA is its advanced voltage regulation technology. This ensures that connected devices receive consistent voltage levels regardless of fluctuations in the incoming power supply. The UPS incorporates Automatic Voltage Regulation (AVR), which stabilizes output voltage and protects sensitive electronics from voltage sags and spikes.

In terms of power capacity, the FE/QFE 500VA is rated for 500VA/300W, making it a robust choice for lightweight applications. It offers battery backup capability, allowing connected devices to continue operating during power outages. The unit’s internal battery is designed for easy replacement, minimizing downtime and maintenance costs.

Another significant characteristic of the Powerware FE/QFE 500VA is its user-friendly interface. The UPS features LED indicators that provide real-time information on battery status, load level, and operational conditions. This intuitive display allows users to quickly assess the performance of the UPS without extensive technical knowledge.

The product is also equipped with surge protection, which safeguards connected devices from voltage spikes that can otherwise cause irreparable damage. This feature is essential for environments with frequent electrical disturbances, providing peace of mind for users.

With dimensions that support efficient use of space, the Powerware FE/QFE 500VA can easily fit into various setups, whether in an office, server room, or home environment. Its lightweight design adds to its portability, allowing users to relocate it as necessary.

In summary, the Powerware FE/QFE 500VA is a highly reliable and feature-rich UPS solution. Its advanced voltage regulation, robust power capacity, user-friendly interface, surge protection, and compact form factor make it an ideal choice for protecting essential electronics from power-related issues. This UPS not only enhances the reliability of critical devices but also contributes to operational efficiency, making it a valuable investment for both personal and professional use.