Powerware FE/QFE 500VA manual 220

Page 36

o k t

k 2c3

snq f t

snq m t

V q r

u a

 

 

 

 

 

FE 4.3–18 kVA (60 Hz)

120

120

MBB or BBM

Figure 12 on page 40

 

(4.3–7 kVA only)

 

 

 

 

 

 

 

 

 

208 or 240

120/208 or 120/240

MBB or BBM

Figure 13 on page 41

 

 

 

For 208V, use BBM only

 

 

 

 

 

 

 

208 or 480 source*/

120/240

MBB or BBM

Figure 14 on page 42

 

240 input

 

 

 

 

 

 

 

 

 

220**

220

BBM

Figure 15 on page 43

 

 

 

 

 

QFE 4.3–18 kVA (50 Hz)

220, 230, or 240

220, 230, or 240

MBB or BBM

Figure 15 on page 43

 

 

 

 

 

*With a step-up or step-down transformer.

**Contact your service representative for (a) single-phase installations that do not have the same input and output voltage, or (b) split-phase installations that require 220 Vac.

30

Powerware® FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com

Image 36
Contents Powerware Ferrups FE/QFE UPS Page Powerware Ferrups FE/QFE UPS FCC Part ICES-003 For Users in GermanyTable of Contents Page Plug-Receptacle Installation Hardwired InstallationIntroduction 7TII -18kVA User’s Guide Safety Warnings P O R T a N T S a F E T Y I N S T R U C T I O N SN G E R R N I N GSikkerhedsanvisninger U T I O NR E Belangrijke Veiligheidsinstructies V a R S E LV a a R A R S C H U W I N GTarkeita Turvaohjeita G E L E TA R a R O I T U SConsignes de sécurité R OSicherheitswarnungen R N U N GH T U N G „Ò·Ûfl· C›„ÈÛÙ.ÃÁ˜ÒÁÙÈÏÔfi95%ÔÈÂflÙÂUPSÍÔÌÙ‹ÛÂÌÂÒ¸fi Avvisi di sicurezza R I C O L OV E R T E N Z a Viktig Sikkerhetsinformasion T E N Z I O N ER L I G Regulamentos de Segurança R S I K T I GI D a D O V E R T Ê N C I aÏðåäóïðåæäåíèÿ ïî ìåðàì áåçîïàñíîñòè R I G OÎïàñíî ÐåäóïðåæäåíèåAdvertencias de Seguridad ÑòîðîæíîL I G R O V E R T E N C I aSäkerhetsföreskrifter E C a U C I Ó NR a K T I G T Setup DimensionsFerrups FE/QFE 500 VA-3.1 kVA Dimensions Ferrups FE/QFE 4.3-18 kVA Dimensions Battery Cabinet DimensionsClearances for the UPS and Battery Cabinets Equipment ClearancesInstallation and Service Clearances Location RequirementsStorage and Operating Environment Page Electrical Installation Bypass Switches Bypass Switch PositionsExternal Bypass Switch Specifications Internal Bypass Switch SpecificationsTypical Hardwired Installation with External Bypass Switch Typical Hardwired Installation with Internal Bypass Switch Page External Bypass Switch Installation External Bypass Switch Wiring Diagrams220 Recommended Wire Sizes V q IGW W u qFE or QFE 500 VA-3.1 kVA FE or QFE 4.3-18 kVAExternal Bypass Switch Terminal Strip Labels Installation Wiring Diagrams for External Bypass Switches Page For 220 Vac, use only a BBM switch For 208 Vac, use only a BBM switch GBB tU-1.4 kVA KVA Standard 15A 50 Hz 220, 230, or 240 Vac Input and Output 60 Hz 120 Vac Input 120 Vac Output DBJ t DFB t CB U For FE 60 Hz 220 Vac, use only a BBM switch Page Internal Bypass Switch Installation Internal Bypass Switch Wiring DiagramsFORU.S.INSTALLATIONS,150AREADTHISIMPORTANTNOTE Internal Bypass Switch BPI Terminal Strip Label Installation Wiring Diagrams for Internal Bypass Switches 60 Hz 120 Vac Input 120 Vac Output For 208 Vac, use only a BBM switch CB U For FE 60 Hz 220 Vac, use only a BBM switch Battery Cabinet Installation Electrician must take these precautionsBefore Installing the Batteries Nominal DC Battery Voltage Installing and Connecting the Batteries WUVflbr dpmsla Never install the batteries in an air-tight enclosure Battery Torque Value Battery Terminal Types Modified Square TorqueFEONorQFEposition4.318kVA Nominal Battery Voltage Replacing the Batteries Recycling the Used Battery Phase Check Internal Bypass Switch External Bypass Switch AC to UPS Load to AC Line Input Vac Q 2Vnb7BC3 7TII -18 kVA User’s Guide

FE/QFE 500VA specifications

The Powerware FE/QFE 500VA is a compact and efficient uninterruptible power supply (UPS) designed to provide reliable power protection for critical electronic equipment. This model is particularly well-suited for small servers, workstations, and networking hardware, ensuring operational continuity in the event of power disturbances, such as surges, brownouts, and outages.

One of the key features of the Powerware FE/QFE 500VA is its advanced voltage regulation technology. This ensures that connected devices receive consistent voltage levels regardless of fluctuations in the incoming power supply. The UPS incorporates Automatic Voltage Regulation (AVR), which stabilizes output voltage and protects sensitive electronics from voltage sags and spikes.

In terms of power capacity, the FE/QFE 500VA is rated for 500VA/300W, making it a robust choice for lightweight applications. It offers battery backup capability, allowing connected devices to continue operating during power outages. The unit’s internal battery is designed for easy replacement, minimizing downtime and maintenance costs.

Another significant characteristic of the Powerware FE/QFE 500VA is its user-friendly interface. The UPS features LED indicators that provide real-time information on battery status, load level, and operational conditions. This intuitive display allows users to quickly assess the performance of the UPS without extensive technical knowledge.

The product is also equipped with surge protection, which safeguards connected devices from voltage spikes that can otherwise cause irreparable damage. This feature is essential for environments with frequent electrical disturbances, providing peace of mind for users.

With dimensions that support efficient use of space, the Powerware FE/QFE 500VA can easily fit into various setups, whether in an office, server room, or home environment. Its lightweight design adds to its portability, allowing users to relocate it as necessary.

In summary, the Powerware FE/QFE 500VA is a highly reliable and feature-rich UPS solution. Its advanced voltage regulation, robust power capacity, user-friendly interface, surge protection, and compact form factor make it an ideal choice for protecting essential electronics from power-related issues. This UPS not only enhances the reliability of critical devices but also contributes to operational efficiency, making it a valuable investment for both personal and professional use.