Powerware FE/QFE 500VA Battery Cabinet Installation, Electrician must take these precautions

Page 59

C H A P T E R 7

BATTERY CABINET INSTALLATION

NOTE If you have an optional Floor Saver battery cabinet, see the Floor Saver instructions that came with your FERRUPS UPS.

W A R N I N G

Only qualified service personnel (such as a licensed electrician) should perform the electrical installation. Risk of electrical shock.

C A U T I O N

Full voltage and current are always present at the battery terminals. The batteries used in this system can produce dangerous voltages, extremely high currents and a risk of electric shock. They may cause severe injury if the terminals are shorted together or to ground (earth). You must be extremely careful to avoid electric shock and burns caused by contacting battery terminals or shorting terminals during battery installation. Do not touch uninsulated battery terminals.

Any battery used with this UPS shall comply with the applicable requirements for batteries in the standard for emergency lighting and power equipment, UL 924. Cabinets are designed to be used with, and batteries must be replaced with, Powerware battery number BAT-XXXX or equivalent.

The electrician must take these precautions:

:Wear protective clothing and eye wear. For 120V battery systems, wear rubber gloves and boots. Batteries contain caustic acids and toxic materials and can rupture or leak if mistreated. Remove rings and metal wristwatches or other metal objects and jewelry. Don’t carry metal objects in your pockets where the objects can fall into the battery cabinet.

:Tools must have insulated handles and must be insulated so that they will not short battery terminals. Do not allow a tool to short a battery terminal to another battery terminal or to the cabinet at any time. Do not lay tools or metal parts on top of the batteries, and do not lay them where they could fall onto the batteries or into the cabinet.

:Install the batteries as shown on the drawing provided with the batteries. When connecting cables, never allow a cable to short across a battery’s terminals, the string of batteries, or to the cabinet.

Powerware® FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com

53

Image 59
Contents Powerware Ferrups FE/QFE UPS Page Powerware Ferrups FE/QFE UPS For Users in Germany FCC Part ICES-003Table of Contents Page Introduction Plug-Receptacle InstallationHardwired Installation 7TII -18kVA User’s Guide R N I N G Safety WarningsP O R T a N T S a F E T Y I N S T R U C T I O N S N G E RR E SikkerhedsanvisningerU T I O N A R S C H U W I N G Belangrijke VeiligheidsinstructiesV a R S E L V a a RR O I T U S Tarkeita TurvaohjeitaG E L E T A R aR O Consignes de sécuritéH T U N G SicherheitswarnungenR N U N G „Ò·Ûfl· C›„ÈÛÙ.ÃÁ˜ÒÁÙÈÏÔfi95%ÔÈÂflÙÂUPSÍÔÌÙ‹ÛÂÌÂÒ¸fi V E R T E N Z a Avvisi di sicurezzaR I C O L O R L I G Viktig SikkerhetsinformasionT E N Z I O N E V E R T Ê N C I a Regulamentos de SegurançaR S I K T I G I D a D OÐåäóïðåæäåíèå Ïðåäóïðåæäåíèÿ ïî ìåðàì áåçîïàñíîñòèR I G O ÎïàñíîV E R T E N C I a Advertencias de SeguridadÑòîðîæíî L I G R OR a SäkerhetsföreskrifterE C a U C I Ó N K T I G T Ferrups FE/QFE 500 VA-3.1 kVA Dimensions SetupDimensions Battery Cabinet Dimensions Ferrups FE/QFE 4.3-18 kVA DimensionsEquipment Clearances Clearances for the UPS and Battery CabinetsLocation Requirements Installation and Service ClearancesStorage and Operating Environment Page Electrical Installation Bypass Switch Positions Bypass SwitchesInternal Bypass Switch Specifications External Bypass Switch SpecificationsTypical Hardwired Installation with External Bypass Switch Typical Hardwired Installation with Internal Bypass Switch Page External Bypass Switch Wiring Diagrams External Bypass Switch Installation220 V q IGW W u q Recommended Wire SizesFE or QFE 4.3-18 kVA FE or QFE 500 VA-3.1 kVAExternal Bypass Switch Terminal Strip Labels Installation Wiring Diagrams for External Bypass Switches Page For 220 Vac, use only a BBM switch For 208 Vac, use only a BBM switch GBB tU-1.4 kVA KVA Standard 15A 50 Hz 220, 230, or 240 Vac Input and Output 60 Hz 120 Vac Input 120 Vac Output DBJ t DFB t CB U For FE 60 Hz 220 Vac, use only a BBM switch Page Internal Bypass Switch Wiring Diagrams Internal Bypass Switch InstallationFORU.S.INSTALLATIONS,150AREADTHISIMPORTANTNOTE Internal Bypass Switch BPI Terminal Strip Label Installation Wiring Diagrams for Internal Bypass Switches 60 Hz 120 Vac Input 120 Vac Output For 208 Vac, use only a BBM switch CB U For FE 60 Hz 220 Vac, use only a BBM switch Electrician must take these precautions Battery Cabinet InstallationBefore Installing the Batteries Nominal DC Battery Voltage Installing and Connecting the Batteries WUVflbr dpmsla Never install the batteries in an air-tight enclosure Battery Torque Value Modified Square Torque Battery Terminal TypesFEONorQFEposition4.318kVA Nominal Battery Voltage Replacing the Batteries Recycling the Used Battery Phase Check Internal Bypass Switch External Bypass Switch AC to UPS Load to AC Line Input Vac Q 2Vnb7BC3 7TII -18 kVA User’s Guide

FE/QFE 500VA specifications

The Powerware FE/QFE 500VA is a compact and efficient uninterruptible power supply (UPS) designed to provide reliable power protection for critical electronic equipment. This model is particularly well-suited for small servers, workstations, and networking hardware, ensuring operational continuity in the event of power disturbances, such as surges, brownouts, and outages.

One of the key features of the Powerware FE/QFE 500VA is its advanced voltage regulation technology. This ensures that connected devices receive consistent voltage levels regardless of fluctuations in the incoming power supply. The UPS incorporates Automatic Voltage Regulation (AVR), which stabilizes output voltage and protects sensitive electronics from voltage sags and spikes.

In terms of power capacity, the FE/QFE 500VA is rated for 500VA/300W, making it a robust choice for lightweight applications. It offers battery backup capability, allowing connected devices to continue operating during power outages. The unit’s internal battery is designed for easy replacement, minimizing downtime and maintenance costs.

Another significant characteristic of the Powerware FE/QFE 500VA is its user-friendly interface. The UPS features LED indicators that provide real-time information on battery status, load level, and operational conditions. This intuitive display allows users to quickly assess the performance of the UPS without extensive technical knowledge.

The product is also equipped with surge protection, which safeguards connected devices from voltage spikes that can otherwise cause irreparable damage. This feature is essential for environments with frequent electrical disturbances, providing peace of mind for users.

With dimensions that support efficient use of space, the Powerware FE/QFE 500VA can easily fit into various setups, whether in an office, server room, or home environment. Its lightweight design adds to its portability, allowing users to relocate it as necessary.

In summary, the Powerware FE/QFE 500VA is a highly reliable and feature-rich UPS solution. Its advanced voltage regulation, robust power capacity, user-friendly interface, surge protection, and compact form factor make it an ideal choice for protecting essential electronics from power-related issues. This UPS not only enhances the reliability of critical devices but also contributes to operational efficiency, making it a valuable investment for both personal and professional use.