Safety Considerations:

For safety agency approval of the system in which the DC-DC power module is installed, the power module must be installed in compliance with the creepage and clearance requirements of the safety agency. The isolation is basic insulation. For applications requiring basic insulation, care must be taken to maintain minimum creepage and clearance distances when routing traces near the power module.

As part of the production process, the power modules are hi-pot tested from primary and secondary at a test voltage of 1500Vdc.

To preserve maximum flexibility, the power modules are not internally fused. An external input line normal blow fuse with a maximum value of 15A is required by safety agencies. A lower value fuse can be selected based upon the maximum dc input current and maximum inrush energy of the power module.

When the supply to the DC-DC converter is less than 60Vdc, the power module meets all of the requirements for SELV. If the input voltage is a hazardous voltage that exceeds 60Vdc, the output can be considered SELV only if the following conditions are met:

1)The input source is isolated from the ac mains by reinforced insulation.

2)The input terminal pins are not accessible.

3)One pole of the input and one pole of the output are grounded or both are kept floating.

4)Single fault testing is performed on the end system to ensure that under a single fault, hazardous voltages do not appear at the module output.

Warranty:

TDK Innoveta’s comprehensive line of power solutions includes efficient, high- density DC-DC converters. TDK Innoveta offers a three-year limited warranty. Complete warranty information is listed on our web site or is available upon request from TDK Innoveta.

TDK Innoveta, Inc.

3320 Matrix Drive, Suite 100 Richardson, Texas 75082

Phone

(877) 498-0099

Toll Free

 

(469) 916-4747

 

Fax

(877) 498-0143

Toll Free

(214)239-3101

support@tdkinnoveta.com

http://www.tdkinnoveta.com/

©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006

Information furnished by TDK Innoveta is believed to be accurate and reliable. However, TDK Innoveta assumes no responsibility for its use, nor for any infringement of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TDK Innoveta. TDK Innoveta components are not designed to be used in applications, such as life support systems, wherein failure or malfunction could result in injury or death. All sales are subject to TDK Innoveta’s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change

(877) 498-0099

15/15

 

Image 15
Contents Optional Features Standard FeaturesOrdering information Option TableProduct Offering Pin Assignment Mechanical SpecificationAbsolute Maximum Ratings Input CharacteristicsIQP48050A050V-000 through -0x9 5V, 50A, 250W Output Electrical DataElectrical Characteristics Trim Trim Up Down Change Resistor Vout Ohm Thermal Performance Thermal measurement locationIQP48050A050V-000 through -009 5V, 50A, 250W Output Thermal Management Wind Tunnel Test Setup Figure10/15 Operating Information = 5.11⋅ Reliability Circuit to increase output voltageLin Vin Vout Cext RLoad Ground Plane Input/Output Ripple and Noise Measurements QualityWarranty Safety Considerations