TDK Half Brick-iHG Input/Output Ripple and Noise Measurements, Safety Considerations

Page 15

Data Sheet: XetaiHG48070A033V, 3.3V/70A Output Half Brick Series

Input/Output Ripple and Noise Measurements:

Battery

2 1

12uH

1 2

220uF

esr<0.1

100KHz

2 1

 

 

+

 

 

Cin

 

Vinput

 

 

 

 

 

esr<0.7

 

100KHz

-

 

 

 

+

Voutput

-

2 1

1

RLoad

Cext

2

Ground Plane

Theinputreflectedrippleismeasuredwithacurre ntprobeandoscilloscope.Theripplecurrentist hecurrentthroughthe 12uHinductor.ThecapacitorCinshallbeatleast 100uF/100V.One220uFortwo100uF/100Vcapacitors inparallelare recommended.

Theoutputripplemeasurementismadeapproximately

9cm(3.5in.)fromthepowermoduleusinganosci

lloscopeand

BNCsocket.ThecapacitorCextislocatedabout5c

 

m(2in.)fromthepowermodule;itsvaluevariesf

romcodetocode

andisfoundontheelectricaldatapageforthepo

wermoduleofinterestundertheripple&noisevol

tagespecificationin

theNotes&Conditionscolumn.

 

 

 

Safety Considerations:

All TDK Innoveta products are certified to regulatory standards by an independent, Certified Administrative Agency laboratory. UL 1950, 3 rd edition (US & Canada), and other global certifications are typically obtainedforeachproductplatform.

Varioussafetyagencyapprovalsarepending ontheiHGproductfamily.Forsafetyagency approval of the system in which the DCDC powermoduleisinstalled,thepowermodule must be installed in compliance with the creepage and clearance requirements of the safety agency. The isolation is basic insulation. For applications requiring basic insulation, care must be taken to maintain minimum creepage and clearance distances whenroutingtracesnearthepowermodule.

Aspartoftheproductionprocess,thepower modules are hipot tested from primary and secondaryatatestvoltageof1500Vdc. The case pin is considered a primarypin for the purposeofhipottesting.

When the supply to the DCDC converter is lessthan60Vdc,thepowermodulemeetsall of the requirements for SELV. If the input voltage is a hazardous voltage that exceeds 60Vdc, the output can be considered SELV onlyifthefollowingconditionsaremet:

1)Theinputsourceisisolatedfromthe acmainsbyreinforcedinsulation.

2)The input terminal pins are not accessible.

3)Onepoleoftheinputandonepoleof the output are grounded or both are keptfloating.

4)Single fault testing is performed on theendsystemtoensurethatundera single fault, hazardous voltages do notappearatthemoduleoutput.

To preserve maximum flexibility, the power modulesarenotinternallyfused.Anexternal inputlinenormalblowfusewiththemaximum ratingstipulatedintheElectricalDatasection isrequiredbysafetyagencies.Alowervalue fuse can be selected based upon the maximum dc input current and maximum inrushenergyofthepowermodule.

©2008TDKInnovetaInc.

(877)498 0099

iHGDatasheet20080515Revision1.1

15/16

 

 

 

Image 15
Contents TDK Innoveta Inc Optional Features Standard FeaturesProduct Offering Ordering informationPin Assignment Mechanical SpecificationAbsolute Maximum Ratings Input CharacteristicsElectrical Data Electrical Characteristics = 34.57kΩ Ta n c e 100 Thermal Performance Thermal Management 12/16 Operating Information 100% Rdown = Δ down − 2 kΩ Input/Output Ripple and Noise Measurements Safety ConsiderationsWarranty ReliabilityQuality