TDK Half Brick-iHG specifications 100% Rdown = Δ down − 2 kΩ

Page 14

Data Sheet: XetaiHG48070A033V, 3.3V/70A Output Half Brick Series

WitharesistorbetweenthetrimandSense()

terminals,theoutputvoltageisadjusteddown. To adjust the output voltage down a percentage of Vout (%Vo) from Vo,nom, the trim resistor should be chosen according to thefollowingequation:

100%

Rdown = (Δ down − 2) kΩ

where

Δdown = Vnom − Vdesired 100% Vnom

The current limit set point does not increase as the module is trimmed down, so the availableoutputpowerisreduced.

Vout(+)

Sense(+)

Trim

Sense(-)

Vout(-)

Circuit to increase output voltage

Witharesistorbetweenthetrimandsense(+) terminals, the output voltage is adjusted up. Toadjusttheoutputvoltageupapercentage of Vout (%Vo) from Vo,nom the trim resistor should be chosen according to the following equation:

 

 

 

V

nom

 

 

 

 

 

 

 

 

 

− 2

⋅ (1

+ Δ

 

) + 1

 

 

 

 

 

up

 

 

 

V

 

 

 

 

 

 

 

 

ref

 

 

 

 

 

R

 

=

 

 

 

 

 

up

 

 

 

Δ up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

where

Δup = Vdesired − Vnom 100% and

Vnom

The value of Vref is found in the Electrical Datasectionforthepowermoduleofinterest. Trimupandtrimdowncurvesarefoundinthe

ElectricalCharacteristicssectionforthepower moduleofinterest.

Themaximumpoweravailablefromthepower module is fixed. As the output voltage is trimmedup,themaximumoutputcurrentmust bedecreasedtomaintainthemaximumrated powerofthemodule.

As the output voltage is trimmed, the output overvoltage set point is not adjusted. Trimming the output voltage too high may causetheoutputovervoltageprotectioncircuit tobetriggered.

Remote Sense: The power modules feature remotesensetocompensatefortheeffectof output distribution drops. The output voltage sense range defines the maximum voltage allowed between the output power terminals andoutputsenseterminals,anditisfoundon

Rup theelectricaldatapageforthepowermodule ofinterest. Iftheremotesensefeatureisnot being used, the Sense(+) terminal should be connected to the Vo(+) terminal and the Sense()terminalshouldbeconnectedtothe Vo()terminal.TheoutputvoltageattheVo(+) andVo()terminalscanbeincreasedbyeither the remote sense or the output voltage adjustment feature. The maximum voltage increase allowed is the larger of the remote senserangeortheoutputvoltageadjustment range;itisnotthesumofboth.

Astheoutputvoltageincreasesduetotheuse of the remote sense, the maximum output current must be decreased for the power moduletoremainbelowitsmaxpowerrating.

EMC Considerations: TDK Innoveta power modulesaredesignedforuseinawidevariety of systems and applications. For assistance with designing for EMC compliance, please contactTDKInnovetatechnicalsupport.

Input Impedance:Thesourceimpedanceof the power feeding the DC/DC converter modulewillinteractwiththeDC/DCconverter. Tominimizetheinteraction,a220470uFinput electrolyticcapacitorshouldbepresent.

©2008TDKInnovetaInc.

(877)498 0099

iHGDatasheet20080515Revision1.1

14/16

 

 

 

Image 14
Contents TDK Innoveta Inc Standard Features Optional FeaturesOrdering information Product OfferingMechanical Specification Pin AssignmentInput Characteristics Absolute Maximum RatingsElectrical Data Electrical Characteristics = 34.57kΩ Ta n c e 100 Thermal Performance Thermal Management 12/16 Operating Information 100% Rdown = Δ down − 2 kΩ Safety Considerations Input/Output Ripple and Noise MeasurementsQuality WarrantyReliability