TDK iEA Series manual 39/41

Page 39

Data Sheet: Belleta® iEA Series –Single Output Eighth Brick

Remote Sense: The power modules feature remote sense to compensate for the effect of output distribution drops. The output voltage sense range defines the maximum voltage allowed between the output power terminals and output sense terminals, and it is found on the electrical data page for the power module of interest. If the remote sense feature is not being used, the Sense(+) terminal should be connected to the Vo(+) terminal and the Sense (-) terminal should be connected to the Vo(-) terminal.

The output voltage at the Vo(+) and Vo(-) terminals can be increased by either the remote sense or the output voltage adjustment feature. The maximum voltage increase allowed is the larger of the remote sense range or the output voltage adjustment range; it is not the sum of both.

As the output voltage increases due to the use of the remote sense, the maximum output current must be decreased for the power module to remain below its maximum power rating.

EMC Considerations: TDK Innoveta power modules are designed for use in a wide variety of systems and applications. For assistance with designing for EMC compliance, please contact TDK Innoveta technical support.

Input Impedance:

The source impedance of the power feeding the DC/DC converter module will interact with the DC/DC converter. To minimize the interaction, a 10-100uF input electrolytic capacitor should be present if the source inductance is greater than 1.5uH.

Reliability:

The power modules are designed using TDK Innoveta’s stringent design guidelines for component derating, product qualification, and design reviews. Early failures are screened out by both burn-in and an automated final test. The MTBF is calculated to be greater than 4.8M hours at full output power and Ta = 40˚C using the Telcordia SR-332 calculation method.

Improper handling or cleaning processes can adversely affect the appearance, testability, and reliability of the power modules. Contact TDK Innoveta technical support for guidance regarding proper handling, cleaning, and soldering of TDK Innoveta’s power modules.

Quality:

TDK Innoveta’s product development process incorporates advanced quality planning tools such as FMEA and Cpk analysis to ensure designs are robust and reliable. All products are assembled at ISO certified assembly plants.

©2004 TDK Innoveta® Inc.

 

￿ (877) 498-0099

iEAFullDatasheet 032707 3/29/2007

Revision 2.0

39/41

 

 

 

 

Image 39
Contents 48V Input, 25A Output Eighth Brick Data Sheet Belleta iEA Series -Single Output Eighth BrickOption Table Feature Recommended Hole Pattern top view Pin Assignment Mechanical SpecificationCharacteristic Min Max Unit Input CharacteristicsElectrical Data Electrical Characteristics Trim Trim Up Down Change Resistor Vout Kohm Output Voltage Thermal Performance 10/41 11/41 12/41 13/41 14/41 15/41 16/41 17/41 18/41 19/41 20/41 21/41 22/41 23/41 24/41 25/41 26/41 27/41 28/41 29/41 30/41 31/41 32/41 33/41 34/41 35/41 Thermal Management Operating Information 510 39/41 40/41 41/41