TDK iEA Series manual Input Characteristics, Characteristic Min Max Unit

Page 4

Data Sheet: Belleta® iEA Series –Single Output Eighth Brick

Absolute Maximum Ratings:

 

 

 

 

Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.

 

Characteristic

Min

Max

Unit

Notes & Conditions

Continuous Input Voltage

-0.5

80

Vdc

 

Transient Input Voltage

---

100

Vdc

100mS max.

 

 

 

 

 

Isolation Voltage

---

1500

Vdc

 

 

 

 

 

 

Storage Temperature

-55

125

˚C

 

 

 

 

 

 

 

 

 

 

Measured at the location specified in the thermal

 

 

 

 

 

 

 

 

measurement figure. Maximum temperature varies

Operating Temperature Range (Tc)

-40

125

˚C

with model number, output current, and module

 

 

 

 

orientation – see curve in thermal performance

 

 

 

 

section of the data sheet.

 

 

 

 

 

Input Characteristics:

Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.

Characteristic

Min

Typ

Max

Unit

Notes & Conditions

Operating Input Voltage

36

48

75

Vdc

 

Maximum Input Current

---

---

4

A

Vin = 0 to Vin,max

 

 

 

 

 

 

Turn-on Voltage

---

33

---

Vdc

 

 

 

 

 

 

 

Turn-off Voltage

26

30

---

Vdc

 

 

 

 

 

 

 

Hysteresis

0.5

3

---

Vdc

 

 

 

 

 

 

 

Startup Delay Time from application of input

---

35

---

mS

Vo = 0 to 0.1*Vo,nom; on/off =on,

voltage

 

 

 

 

Io=Io,max, Tc=25˚C

 

 

 

 

 

 

Startup Delay Time from on/off

---

35

---

mS

Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom,

 

 

 

 

 

Io=Io,max,Tc=25˚C

 

 

 

 

 

 

Output Voltage Rise Time

---

50

---

mS

Io=Io,max,Tc=25˚C, Vo=0.1 to 0.9*Vo,nom

 

 

 

 

 

 

Inrush Transient

---

---

0.2

A2s

 

 

 

 

 

 

 

Input Reflected Ripple

---

15

---

mApp

See input/output ripple and noise

 

 

 

 

 

measurements figure; BW = 20 MHz

 

 

 

 

 

 

Input Ripple Rejection

---

55

---

dB

@120Hz

 

 

 

 

 

 

Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 10A is required, see the Safety Considerations section of the data sheet.

©2004 TDK Innoveta® Inc.

 

￿ (877) 498-0099

iEAFullDatasheet 032707 3/29/2007

Revision 2.0

4/41

 

 

 

 

Image 4
Contents Data Sheet Belleta iEA Series -Single Output Eighth Brick 48V Input, 25A Output Eighth BrickOption Table Feature Mechanical Specification Recommended Hole Pattern top view Pin AssignmentInput Characteristics Characteristic Min Max UnitElectrical Data Electrical Characteristics Trim Trim Up Down Change Resistor Vout Kohm Output Voltage Thermal Performance 10/41 11/41 12/41 13/41 14/41 15/41 16/41 17/41 18/41 19/41 20/41 21/41 22/41 23/41 24/41 25/41 26/41 27/41 28/41 29/41 30/41 31/41 32/41 33/41 34/41 35/41 Thermal Management Operating Information 510 39/41 40/41 41/41