SUPER MICRO Computer X6DH8-G2, X6DHE-G2 manual Overheat LED OH, Power Fail LED

Page 32

X6DH8-G2/X6DHE-G2 User's Manual

Overheat LED (OH)

Connect an LED to the OH connec- tion on pins 7 and 8 of JF1 to pro- vide advanced warning of chassis overheating. Refer to the table on the right for pin definitions.

Overheat (OH) LED

Pin Definitions

(JF1)

Pin

Number Definition

7Vcc

8Control

Signal

Power Fail LED

The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions.

Overheat (OH) LED

Pin Definitions

(JF1)

Pin

Number Definition

5Vcc

6Control

Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J32

 

24-Pin ATX PWR

 

JPF

 

 

 

 

 

 

 

 

 

J1B4

Force PWR ON

 

 

Fan6 Fan5

4-Pin

 

 

 

 

 

 

 

KB/

 

 

 

 

 

PWR

 

 

 

 

Mouse

 

 

 

 

 

 

 

 

 

 

 

J9

 

 

 

 

 

DIMM 1B (Bank 1)

 

 

 

Fan7

 

PWR

 

 

J24

 

 

 

 

SMBus

PW

 

8-pin

Fault

 

PWR

 

J1D1

 

JP13

 

3rd PS Alarm

1

 

 

n

 

 

a

 

 

F

 

 

 

 

 

 

OH LED

OH LED

 

 

20

19

USB0/1

 

 

 

DIMM 1A (Bank 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM1

J6

 

 

 

DIMM 2B (Bank 2)

 

 

 

 

 

 

 

 

 

 

 

DIMM 2A (Bank 2)

 

 

 

 

 

 

Parrallel Port

 

 

 

 

DIMM 3B (Bank 3)

 

 

 

 

 

 

 

 

 

 

DIMM 3A (Bank 3)

 

 

 

 

 

 

 

 

 

 

 

DIMM 4B (Bank 4)

 

 

 

 

 

 

J23

 

 

 

DIMM 4A (Bank 4)

 

 

 

 

 

 

VGA

 

 

 

 

 

 

 

 

 

 

J5

 

 

 

SUPER

®

X6DH8-G2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLAN1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLAN2

 

 

 

 

 

 

 

 

North

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPG1

VGA

 

 

 

 

 

Bridge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

 

 

 

 

 

 

 

 

 

 

 

J20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAGE-

 

J15

X8 PCI-Epx #6

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

Super

 

 

 

 

Clr

 

 

 

 

 

 

 

 

J16

X8 PCI-Epx #5

 

I/O

 

 

 

ICH5R

 

 

J7

 

 

 

 

 

 

 

 

 

CMOS

 

 

 

 

 

 

 

 

 

 

 

COM2

 

 

 

 

 

 

 

 

 

 

 

JBT1

JWD

GLAN

 

J17

X4 PCI-Epx #4

 

 

 

 

 

 

WD Enable

BIOS

 

CTLR

 

 

 

 

 

 

 

 

 

 

 

 

 

82546

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU 1

 

 

CPU 2

 

 

 

Fan8

 

 

 

 

 

 

 

IPMI

 

 

 

 

 

 

 

 

SI/O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JF1

 

Control

 

 

 

 

 

 

 

 

 

FP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JP15

 

JD1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reboot

 

 

 

 

 

 

 

Opt. Enable

 

 

 

 

 

 

Fan2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JOH1

 

 

 

 

 

 

 

Alrm

Reset

 

JP14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan3

 

JL1CH Intru

 

 

 

 

 

 

 

 

 

 

 

Floppy

IDE2

IDE1

 

 

JP8

J4

J3

 

 

Ground

X Power LED

HDD LED

NIC1 LED

NIC2 LED

Overheat LED

Power Fail LED

NMI

X

Vcc

Vcc

Vcc

Vcc

Vcc

Vcc

 

 

 

 

 

 

J11

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

USB4

 

 

 

 

 

 

 

 

 

 

J14

 

PCI-X #3

133 MHz

 

 

 

 

 

JPA1 SCSI

SCSICH

 

Enable

 

 

 

 

 

 

 

Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

7902

 

 

GLAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ultra320

 

 

JPL1

J13

 

PCI-X #2

100 MHz

 

 

 

PXH

 

 

 

SCSI

 

 

 

 

 

 

 

 

 

 

 

 

CTRL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J12

 

PCI-X #1

100 MHz ZCR

 

J22

 

JS2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPA2

SCSI CHA Term. Ena

JA1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WOR JWOR

 

 

 

 

SMBUS

 

SATA1

JPA3

SCSI CHB Term. Ena

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JS1

 

Ultra 320 SCSI CH B

 

 

 

Fan4

 

 

 

 

 

 

 

Speaker JD2

USB2/3

SATA0

 

 

 

 

 

 

 

WOL JWOL

 

 

JA2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

Ground

 

Reset

Reset Button

 

Pwr

Power Button

2

1

 

2-12

Image 32
Contents Super Page About This Manual Manual OrganizationTable of Contents Troubleshooting Bios AppendicesChecklist OverviewContacting Supermicro HeadquartersEurope Asia-PacificX6DH8-G2/X6DHE-G2 Image X6DH8-G2/X6DHE-G2 Motherboard Layout X6DH8-G2Quick Reference X6DH8-G2/X6DHE-G2 Jumper Description Default SettingConnector Description Motherboard Features M o r yChipset Expansion SlotsAcpi Features DimensionsOnboard I/O OtherBlock Diagram of the E7520 Lindenhurst Chipset Chipset Overview Special Features Recovery from AC Power LossEnvironmental Temperature Control PC Health MonitoringAcpi Features CPU Fan Auto-Off in Sleep ModeCPU Overheat LED and Control System Resource AlertSlow Blinking LED for Suspend-State Indicator Main Switch Override MechanismMicrosoft OnNow External Modem Ring-OnPower Supply Super I/OPage Unpacking PrecautionsStatic-Sensitive Devices Nocona Processor and Heatsink Installation CPU InstallationCEK Heatsink Installation To Un-install the Heatsink PGA604 Socket Empty and with Processor Installed Mounting the Motherboard in the ChassisMemory Support Installing DIMMsDimm Installation See Figure I/OPorts/Control Panel Connectors I/O Port Locations and DefinitionsJF1 Header Pins Front Control PanelProcessor Power Connector Connecting CablesATX Power Connector Power LED NMI ButtonNIC1/NIC2 LED Indicators HDD LEDPower Fail LED Overheat LED OHReset Button Power ButtonChassis Intrusion Universal Serial Bus USB0/1Front Panel Universal Serial Bus Headers Serial PortsGlan Giga-bit Ethernet Ports ATX PS/2 Keyboard and PS/2 Mouse PortsPower LED/Speaker Fan HeadersWake-On-Ring Wake-On-LANConnector SMB Power I2 CExplanation Jumpers Jumper SettingsGlan Enable/Disable Cmos Clear Watch DogVGA Enable/Disable Alarm ResetPower Fault Power FaultScsi Enable/Disable *ForX6DH8 only Scsi CH A/B Termination Enable/Disable *ForX6DH8 onlyOverheat LED JOH1 Onboard IndicatorsGlan LEDs Parallel Port, Floppy/Hard Disk Drive and Scsi Connections Parallel Printer PortFloppy Connector IDE ConnectorsUltra320 Scsi Connectors X6DH8-G2 Only Pin Ultra320 Scsi Connectors JA1 and JA2Troubleshooting Procedures Before Power OnNo Power Or installing any hardware componentsLosing the System’s Setup Configuration Technical Support ProceduresMemory Errors Frequently Asked Questions Question How do I update my BIOS?Returning Merchandise for Service Question Whats on the CD that came with my motherboard?System Bios How To Change the Configuration DataStarting the Setup Utility IntroductionPress the Delete key to enter Setup Running SetupMain Bios Setup Main Bios Setup Menu Main Setup FeaturesSerial ATA Serial ATA RAID EnableNative Mode Operation LBA Mode Control TypeMulti-Sector Transfer Bit I/OAdvanced Setup Transfer ModeUltra DMA Mode System MemoryBoot Features Quick Boot ModeQuiet Boot Acpi ModeMemory Cache Cache System Bios Area Cache Video Bios AreaCache Base 0-512K Cache Base 512K-640KPCI Configuration Onboard Glan Gigabit- LAN Oprom ConfigureOnboard Scsi Oprom Configure Default Primary Video AdapterPCI Parity Error Forwarding Reset Configuration DataEnable Master Latency TimerLarge Disk Access Mode Force Compliance ModeClock Spectrum Feature Dram Data Integrity ModeSerr Signal Condition Enabling Multi-Media TimerUSB Function Legacy USB SupportNo Execute Mode Memory Protection *Available when supported Processor Power ManagementThermal Management 2 *Available when supported by the CPU Adjacent Cache Line Prefetch *Available when supported byDevice Configuration Serial Port aBase I/O Address InterruptDMA Channel Floppy Disk ControllerDMI Event Logging Event Log ValidityConsole Redirection COM Port AddressBaud Rate Console TypeHardware Monitor Logic CPU Temperature Threshold Fan Speed Control ModesSupervisor Password Is User Password IsSet Supervisor Password Set User PasswordFixed Disk Boot Sector Password on BootBoot +Removable DevicesCdrom Drive +Hard DriveLoad Setup Defaults ExitExit Saving Changes Exit Discarding ChangesSave Changes Post Code Description Recoverable Post ErrorsTerminal Post Errors Post Code Description Post Code Description Post Code Description Following are for boot block in Flash ROM Page Introduction to the Intel ICH5R I/O Controller Hub Enhanced Mode ATA Operate ModeCombined Mode Appendix B Software Installation Instructions Using the Adaptec RAID Configuration Utility ARC Using the Array Configuration Utility ACUManaging Arrays From the ARC menu, select Array Configuration Utility ACU Viewing Array PropertiesDeleting Arrays RAID 1 only-the following prompt is also displayedCreating Arrays To create an arrayAssigning Array Properties Raid Level Create Via When Appropriate When you are finished, press Done as the screen shown below Adding a Bootable Array Deleting a Bootable ArrayAdding/Deleting Hotspares Initializing Disk Drives To initialize drivesPage Page Rebuilding Arrays To Rebuild an arrayUsing the Disk Utilities To access the disk utilitiesPage To Exit Adaptec RAID Configuration Utility You can choose from the following optionsInstalling Intels ICH5R Driver by Adaptec and the OS Installing Other Software Programs and Drivers Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control