SUPER MICRO Computer X6DHE-G2, X6DH8-G2 Front Panel Universal Serial Bus Headers, Serial Ports

Page 35

Chapter 2: Installation

Front Panel Universal

Serial Bus Headers

Extra USB headers (FPUSB2/ FPUSB3/FPUSB4) can be used for front side USB access. You will need a USB cable to use either connection. Refer to the tables on the right for pin definitions.

Serial Ports

The COM1 (J6) and COM2 (J7) se- rial ports are located under the parallel port (COM1) annd next to IPMI (COM2). See the table on the right for pin definitions.

Front Panel Universal Serial Bus Pin

Definitions

FPUSB2/FPUSB3

Pin

 

 

Pin

 

 

Number

Definition

Number

Definition

1

 

Vcc

2

 

Vcc

3

 

Data-

4

 

Data-

5

 

Data+

6

 

Data+

7

 

Ground

8

 

Ground

9

 

Key

10

 

NA

 

 

 

 

Universal Serial Bus Pin Definitions

 

 

FP USB4

 

 

 

 

 

 

 

 

 

 

Pin

 

 

 

 

 

Number

Definition

 

 

 

1

Vcc

 

 

 

 

2

Data-

 

 

 

 

3

Data+

 

 

 

 

4

Ground

 

 

 

 

5

NA

 

 

Serial Port Pin Definitions

(COM1)

Pin Number

Definition

Pin Number

Definition

1

DCD

6

DSR

2

RXD

7

RTS

3

TXD

8

CTS

4

DTR

9

RI

5

GND

 

 

 

 

 

Serial Port Pin Definitions

 

 

(COM2)

 

 

 

 

 

Pin Number

Definition

Pin Number

Definition

1

DCD

6

DSR

2

RXD

7

RTS

3

TXD

8

CTS

4

DTR

9

RI

5

GND

10

NC

COM1

 

 

 

 

 

 

 

 

 

 

 

 

J32

 

 

24-Pin ATX PWR

 

JPF

 

 

 

 

 

 

 

 

Fan6 Fan5

4-Pin

J1B4

 

Force PWR ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KB/

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

Mouse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J9

 

 

 

 

 

 

 

DIMM 1B (Bank 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USB0/1

 

 

 

 

 

 

 

 

DIMM 1A (Bank 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM1

J6

 

 

 

 

 

 

 

DIMM 2B (Bank 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMM 2A (Bank 2)

 

 

 

 

 

ParrallelPortJLAN1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMM 3B (Bank 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMM 3A (Bank 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMM 4B (Bank 4)

 

 

 

 

 

J23

 

 

 

 

 

 

 

 

DIMM 4A (Bank 4)

 

 

 

 

 

VGA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J5

 

 

 

 

 

 

 

SUPER

®

X6DH8-G2

 

 

 

 

 

 

 

 

 

 

 

 

GLAN1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan7

 

PWR

 

 

 

J24

 

 

 

 

 

SMBus

 

 

 

 

CPU 1

 

 

 

 

 

 

 

 

 

CPU 2

 

 

PW

JP12

 

8-pin

 

Fault

 

PWR

 

 

 

J1D1

 

 

JP13

3rd PS Alarm

1

 

 

 

n

 

 

 

a

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JF1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JP15 JD1

 

 

 

 

 

 

 

 

 

 

 

 

Reboot

 

 

 

 

Opt. Enable

 

 

 

 

 

 

Fan2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JOH1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLAN2

JPG1VGA

Enable

RAGE-

5

 

X8 PCI-Epx #6

X

1J

 

 

 

 

61

 

 

 

X8 PCI-Epx #5

 

 

 

 

 

J

 

 

 

 

 

GLAN

 

7

 

X4 PCI-Epx #4

CTLR

 

1J

 

82546

 

 

 

Super I/O

North

Bridge

ICH5R

J20

Clr

 

J7

CMOS

 

 

 

COM2

 

JBT1

JWD

WD Enable

 

 

 

 

BIOS

 

 

 

 

 

Fan8

 

 

 

 

IPMI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SI/O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alrm

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JL1CH Intru

 

Fan3

 

 

 

 

 

 

 

 

 

 

 

 

Floppy

IDE2

IDE1

 

JP8

J4

J3

 

COM2

GLAN Enable JPL1

Battery

 

 

 

 

 

 

 

 

 

 

 

J11

 

 

 

 

 

 

USB4

 

 

 

41

 

PCI-X #3 133 MHz

 

 

 

J

 

 

 

 

 

 

PCI-X #2 100 MHz

 

 

 

31

 

 

 

 

J

 

 

 

 

 

21

 

PCI-X #1 100 MHz ZCR

 

 

 

 

 

 

 

J

 

 

 

 

 

 

WOR

JWOR

 

 

 

 

 

JWOL

 

 

 

 

WOL

 

 

 

 

 

FP USB

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

JPA1 SCSI

CH

 

 

 

 

 

 

 

 

 

 

Enable

SCSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7902

 

 

 

 

 

 

 

PXH

 

 

 

 

CTRL

 

320

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ultra

 

 

 

J22

JS2

 

 

 

 

 

 

 

 

 

 

JPA2

 

SCSI CHA Term. Ena

JA1

 

 

 

 

 

 

 

 

 

 

 

SMBUS

 

SATA1

JPA3

 

SCSI CHB Term. Ena

 

 

 

 

 

 

Speaker

 

 

 

 

JS1

 

 

Ultra 320 SCSI CH B

 

 

 

Fan4

JD2

USB2/3

SATA0

JA2

 

 

 

 

 

 

FP USB 2/3

2-15

Image 35
Contents Super Page Manual Organization About This ManualTable of Contents Troubleshooting Appendices BiosOverview ChecklistAsia-Pacific Contacting SupermicroHeadquarters EuropeX6DH8-G2/X6DHE-G2 Image X6DH8-G2 X6DH8-G2/X6DHE-G2 Motherboard LayoutQuick Reference X6DH8-G2/X6DHE-G2 Jumper Description Default SettingConnector Description Expansion Slots Motherboard FeaturesM o r y ChipsetOther Acpi FeaturesDimensions Onboard I/OBlock Diagram of the E7520 Lindenhurst Chipset Chipset Overview PC Health Monitoring Special FeaturesRecovery from AC Power Loss Environmental Temperature ControlSystem Resource Alert Acpi FeaturesCPU Fan Auto-Off in Sleep Mode CPU Overheat LED and ControlExternal Modem Ring-On Slow Blinking LED for Suspend-State IndicatorMain Switch Override Mechanism Microsoft OnNowSuper I/O Power SupplyPage Unpacking PrecautionsStatic-Sensitive Devices CPU Installation Nocona Processor and Heatsink InstallationCEK Heatsink Installation To Un-install the Heatsink Mounting the Motherboard in the Chassis PGA604 Socket Empty and with Processor InstalledMemory Support Installing DIMMsDimm Installation See Figure I/O Port Locations and Definitions I/OPorts/Control Panel ConnectorsFront Control Panel JF1 Header PinsProcessor Power Connector Connecting CablesATX Power Connector NMI Button Power LEDHDD LED NIC1/NIC2 LED IndicatorsOverheat LED OH Power Fail LEDPower Button Reset ButtonUniversal Serial Bus USB0/1 Chassis IntrusionSerial Ports Front Panel Universal Serial Bus HeadersATX PS/2 Keyboard and PS/2 Mouse Ports Glan Giga-bit Ethernet PortsFan Headers Power LED/SpeakerWake-On-LAN Wake-On-RingSMB Power I2 C ConnectorExplanation Jumpers Jumper SettingsGlan Enable/Disable Watch Dog Cmos ClearAlarm Reset VGA Enable/DisablePower Fault Power FaultScsi CH A/B Termination Enable/Disable *ForX6DH8 only Scsi Enable/Disable *ForX6DH8 onlyOverheat LED JOH1 Onboard IndicatorsGlan LEDs Parallel Printer Port Parallel Port, Floppy/Hard Disk Drive and Scsi ConnectionsIDE Connectors Floppy ConnectorPin Ultra320 Scsi Connectors JA1 and JA2 Ultra320 Scsi Connectors X6DH8-G2 OnlyOr installing any hardware components Troubleshooting ProceduresBefore Power On No PowerLosing the System’s Setup Configuration Technical Support ProceduresMemory Errors Question How do I update my BIOS? Frequently Asked QuestionsQuestion Whats on the CD that came with my motherboard? Returning Merchandise for ServiceIntroduction System BiosHow To Change the Configuration Data Starting the Setup UtilityPress the Delete key to enter Setup Running SetupMain Bios Setup Main Setup Features Main Bios Setup MenuSerial ATA Serial ATA RAID EnableNative Mode Operation Bit I/O LBA Mode ControlType Multi-Sector TransferSystem Memory Advanced SetupTransfer Mode Ultra DMA ModeAcpi Mode Boot FeaturesQuick Boot Mode Quiet BootCache Base 512K-640K Memory Cache Cache System Bios AreaCache Video Bios Area Cache Base 0-512KDefault Primary Video Adapter PCI ConfigurationOnboard Glan Gigabit- LAN Oprom Configure Onboard Scsi Oprom ConfigureLatency Timer PCI Parity Error ForwardingReset Configuration Data Enable MasterDram Data Integrity Mode Large Disk Access ModeForce Compliance Mode Clock Spectrum FeatureLegacy USB Support Serr Signal ConditionEnabling Multi-Media Timer USB FunctionAdjacent Cache Line Prefetch *Available when supported by No Execute Mode Memory Protection *Available when supportedProcessor Power Management Thermal Management 2 *Available when supported by the CPUInterrupt Device ConfigurationSerial Port a Base I/O AddressEvent Log Validity DMA ChannelFloppy Disk Controller DMI Event LoggingConsole Type Console RedirectionCOM Port Address Baud RateFan Speed Control Modes Hardware Monitor Logic CPU Temperature ThresholdSet User Password Supervisor Password IsUser Password Is Set Supervisor PasswordPassword on Boot Fixed Disk Boot Sector+Hard Drive Boot+Removable Devices Cdrom DriveExit Discarding Changes Load Setup DefaultsExit Exit Saving ChangesSave Changes Post Code Description Recoverable Post ErrorsTerminal Post Errors Post Code Description Post Code Description Post Code Description Following are for boot block in Flash ROM Page Introduction to the Intel ICH5R I/O Controller Hub Enhanced Mode ATA Operate ModeCombined Mode Appendix B Software Installation Instructions Using the Array Configuration Utility ACU Using the Adaptec RAID Configuration Utility ARCManaging Arrays RAID 1 only-the following prompt is also displayed From the ARC menu, select Array Configuration Utility ACUViewing Array Properties Deleting ArraysTo create an array Creating ArraysAssigning Array Properties Raid Level Create Via When Appropriate When you are finished, press Done as the screen shown below Deleting a Bootable Array Adding a Bootable ArrayAdding/Deleting Hotspares To initialize drives Initializing Disk DrivesPage Page To Rebuild an array Rebuilding ArraysTo access the disk utilities Using the Disk UtilitiesPage You can choose from the following options To Exit Adaptec RAID Configuration UtilityInstalling Intels ICH5R Driver by Adaptec and the OS Installing Other Software Programs and Drivers Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control