SUPER MICRO Computer LSI 2108/2208 user manual RAID 10 Example, RAID 5 Example

Page 11

Chapter 1: Introduction to the LSI MegaRAID Software Utility

RAID 10

RAID 10, a combination of RAID 1 and RAID 0, provides superb system performance and system security. RAID 10 mirrors small blocks of data to a series of RAID 1 drive groups. Then the first RAID 1 drive in a drive group duplicates its data to the second drive. RAID 10 requires a minimum of 4 drives. Any additional drives must be be added in pairs (6 drives, 8 drives, etc). The following illustration provides a visual example of a RAID 10 virtual drive group.

RAID 10

RAID 0

 

RAID 1

 

RAID 1

Drive A

Drive B

Drive C

Drive D

Segment 1

Segment 1

Segment 2

Segment 2

 

Duplicate

 

Duplicate

Segment 3

Segment 3

Segment 4

Segment 4

 

Duplicate

 

Duplicate

RAID 10 Example

RAID 5

RAID 5 provides high data throughput by implementing block-level striping with par- ity data distributed across all drives. A RAID 5 configuration can survive the loss of a single drive failure because the parity drive can be used to re-create the missing data. RAID 5 requires at least 3 drives. The following illustration provides a visual example of a RAID 5 virtual drive group with three drives.

RAID 5

Drive A

Drive B

Drive C

Segment 1

Segment 2

Parity (1,2)

Segment 3

Parity (3,4)

Segment 4

Parity (5,6)

Segment 5

Segment 6

RAID 5 Example

1-5

Image 11
Contents USER’S Manual Page Conventions Used in This Manual About This ManualManual Organization Asia-Pacific Contacting SupermicroHeadquarters EuropePreface Table of Contents Overview of the LSI 2108/2208 SAS Controller Features of the LSI 2108/2208 Controller6Gb/s SAS Interface High PerformanceFunctions of the LSI MegaRAID Utility Drive Features Supported by the LSI MegaRAID UtilityRAID 1 Example RAID Levels Supported by the 2108/2208 ControllerRAID 0 Example RAID 5 Example RAID 10 ExampleRAID 6 Example RAID 50 ExampleRAID RAID 6RAID RAID 60 ExamplePage Adapter Selection Using the LSI MegaRAID Configuration UtilityLSI MegaRAID Main Screen LSI Configuration Utility Main ScreenController Information Advanced Software OptionsController Selection Controller PropertiesA.R.T DescriptionNCQ Virtual Drives Scan DevicesVirtual Drive Properties Drives DrivesConfiguration Wizard Add Configuration Adding a ConfigurationSpan Definition Configuring Drives ManuallyAdd Drives Virtual Drive Definition Configuration Preview Logical View Logical ViewPhysical View Event Information EventsExit