SUPER MICRO Computer LSI 2108/2208 Configuring Drives Manually, Add Drives, Span Definition

Page 25

Chapter 2: Configuring the LSI MegaRAID Settings

Configuring Drives Manually

1.In the Add Configuration screen, select Manual Configuration and click Next to begin adding drives. The following screen displays.

Add Drives

2.Select the drives you want to add to the array and click Add to Array. To undo any drive addition, select the drive and click Reclaim.

3.After all desired drives are added to the drive group, select Accept DG to create a drive group. Multiple drive groups can be created by adding addi- tional available drives. When finished creating drive groups, select Next.

4.In the pull-down menu of the Span Definition screen, select the drive group you want to add to SPAN and click Add to SPAN, then click Next.

Span Definition

Note: For RAID 10, 50, and 60, two or more drive groups must be added to SPAN.

2-11

Image 25
Contents USER’S Manual Page Manual Organization About This ManualConventions Used in This Manual Headquarters Contacting SupermicroEurope Asia-PacificPreface Table of Contents Overview of the LSI 2108/2208 SAS Controller Features of the LSI 2108/2208 Controller6Gb/s SAS Interface High PerformanceFunctions of the LSI MegaRAID Utility Drive Features Supported by the LSI MegaRAID UtilityRAID 0 Example RAID Levels Supported by the 2108/2208 ControllerRAID 1 Example RAID 5 Example RAID 10 ExampleRAID 6 Example RAID 50 ExampleRAID RAID 6RAID RAID 60 ExamplePage Adapter Selection Using the LSI MegaRAID Configuration UtilityLSI MegaRAID Main Screen LSI Configuration Utility Main ScreenController Selection Advanced Software OptionsController Properties Controller InformationA.R.T DescriptionNCQ Virtual Drives Scan DevicesVirtual Drive Properties Drives DrivesConfiguration Wizard Add Configuration Adding a ConfigurationAdd Drives Configuring Drives ManuallySpan Definition Virtual Drive Definition Configuration Preview Physical View Logical ViewLogical View Event Information EventsExit