SUPER MICRO Computer LSI 2108/2208 user manual Configuration Preview

Page 27

Chapter 2: Configuring the LSI MegaRAID Settings

Always Write-Back: Use this option to write data only to the cache, even if a battery backup is bad or missing. (This option is not recommended because cached data will be lost in the event of a power outage.)

IO Policy: The IO Policy applies only to reads on a specific virtual drive and does not affect the Read Policy or the Write Policy. Select between the following options:

Cached: Use this option to buffer all IO reads in cache memory.

Direct: Use this option to simultaneously transfer data to the cache and host.

Drive Cache: This applies to the cache on physical drives in the array. Select between Enable, Disable, and Unchanged.

Disable BGI: Select whether or not to disable background initialization.

Select Size: Enter a value to set the desired size of the virtual drive. The maximum capacity that can be set is displayed in the Virtual Drives window (right side of Virtual Drive Definition screen)

6.When finished configuring the virtual drive options, select Accept then select Next to proceed to the configuration preview screen (shown below).

Configuration Preview

7.Select Accept to save the configuration. Continue to select Accept in the fol- lowing screens until you are prompted to initialize the virtual drive.

8.Select Yes when prompted to initialize the drive. Initialization options are identical to Virtual Drives section (see page 2-6).

2-13

Image 27
Contents USER’S Manual Page About This Manual Manual OrganizationConventions Used in This Manual Asia-Pacific Contacting SupermicroHeadquarters EuropePreface Table of Contents Overview of the LSI 2108/2208 SAS Controller Features of the LSI 2108/2208 Controller6Gb/s SAS Interface High PerformanceFunctions of the LSI MegaRAID Utility Drive Features Supported by the LSI MegaRAID UtilityRAID Levels Supported by the 2108/2208 Controller RAID 0 ExampleRAID 1 Example RAID 5 Example RAID 10 ExampleRAID 6 Example RAID 50 ExampleRAID RAID 6RAID RAID 60 ExamplePage Adapter Selection Using the LSI MegaRAID Configuration UtilityLSI MegaRAID Main Screen LSI Configuration Utility Main ScreenController Information Advanced Software OptionsController Selection Controller PropertiesA.R.T DescriptionNCQ Virtual Drives Scan DevicesVirtual Drive Properties Drives DrivesConfiguration Wizard Add Configuration Adding a ConfigurationConfiguring Drives Manually Add DrivesSpan Definition Virtual Drive Definition Configuration Preview Logical View Physical ViewLogical View Event Information EventsExit