Chapter 2: Configuring the LSI MegaRAID Settings
•Always
IO Policy: The IO Policy applies only to reads on a specific virtual drive and does not affect the Read Policy or the Write Policy. Select between the following options:
•Cached: Use this option to buffer all IO reads in cache memory.
•Direct: Use this option to simultaneously transfer data to the cache and host.
Drive Cache: This applies to the cache on physical drives in the array. Select between Enable, Disable, and Unchanged.
Disable BGI: Select whether or not to disable background initialization.
Select Size: Enter a value to set the desired size of the virtual drive. The maximum capacity that can be set is displayed in the Virtual Drives window (right side of Virtual Drive Definition screen)
6.When finished configuring the virtual drive options, select Accept then select Next to proceed to the configuration preview screen (shown below).
Configuration Preview
7.Select Accept to save the configuration. Continue to select Accept in the fol- lowing screens until you are prompted to initialize the virtual drive.
8.Select Yes when prompted to initialize the drive. Initialization options are identical to Virtual Drives section (see page