SUPER MICRO Computer X7DBi+ user manual Floppy Connector, Simlp Slot, Floppy Simlp

Page 51

Chapter 2: Installation

Floppy Connector

Floppy Drive Connector Pin Definitions (Floppy)

The floppy connector is located next to the compact flash card slot. See the table below for pin definitions.

Pin#

Definition

1

Ground

3

Ground

5

Key

7

Ground

9Ground

11Ground

13Ground

15Ground

17Ground

19Ground

21Ground

23Ground

25Ground

27Ground

29Ground

31Ground

33Ground

Pin # Definition

2

FDHDIN

4

Reserved

6

FDEDIN

8

Index

10Motor Enable

12Drive Select B

14Drive Select B

16Motor Enable

18DIR

20STEP

22Write Data

24Write Gate

26Track 00

28Write Protect

30Read Data

32Side 1 Select

34Diskette

SIMLP Slot

There is a SIMLP (Supermicro Intel- ligent Management) add-on card slot (Slot 7) on the motherboard. Refer to the layout below for the IPMI Slot location.

 

 

DIMM 4D (Bank4)

FAN5

Bank4

DIMM 4C (Bank4)

DIMM 4B (Bank4)

FAN6

 

DIMM 4A (Bank4)

CPU FAN1 24-Pin ATX PWR

8-Pin PWR

 

FAN7

4-Pin PWR

FP CTRL

 

 

 

Buzzer

A.Floppy

B.SIMLP 2.0

KB/Mouse

DIMM 3D (Bank3)

PSF SMBus PSJ3P

Bank3

USB 0/1

DIMM 3C(Bank3)

DIMM 3B(Bank3)

DIMM 3A (Bank3)

DIMM 2D(Bank2)

JAR

FAN1

COM1

Bank2

 

Printer

VGA

Bank1

 

GLAN1

DIMM 2C (Bank2)

DIMM 2B(Bank2)

DIMM 2A(Bank2)

DIMM 1D(Bank1)

DIMM 1C(Bank1)

DIMM 1B(Bank1)

DIMM 1A(Bank1)

CPU1

FAN2

JD1

LE1

JOH1

GLAN2

X7DBi+

VGA

CTRL

Memory

VGA

GLAN

CTRL

Intel 5000P

(North Bridge)

Slot7 SIMLP

B

JPG1

 

Slot6 PCI-E X8

 

JWD

 

J28

 

Slot5 PCI-E X4

WOL

J27

Slot4 PCI-E X8

USB 4

 

Slot3 PCI-E X4

 

Slot2 PCI-E X4

 

Slot1 PCI-X 133MHZ

 

CPU2

I-SATA0

I-SATA1

I-SATA2

I-SATA3

I-SATA4

I-SATA5

BIOS

 

 

 

JBT1

 

JPL1

SI/O

 

 

 

 

 

Intel

 

 

 

 

 

 

 

 

JPL2

 

ESB 2

 

 

 

 

 

 

 

 

JK1

 

(SouthBridge)

 

 

 

 

 

 

 

 

 

KEYLOCK

 

 

 

FAN3

 

 

FAN8

 

CPU FAN2

A

 

 

Floppy

Compact Flash

IDE#1

JWF1

J29J30

 

JCF1

 

 

Battery

WOR

USB 2/3

SMB

JL1 FAN4

2-31

Image 51
Contents Super Manual Revision Release Date June 25 Preface About This ManualManual Organization Conventions Used in the ManualTable of Contents Table of Contents Security Setup Boot Setup Exit Main Bios SetupChecklist OverviewIntroduction Headquarters Contacting SupermicroX7DBi+ Image Not drawn to scale X7DBi+ Motherboard LayoutQuick Reference X7DBi+ Jumper Description Default SettingPC Health Monitoring MemoryChipset Expansion SlotsOther Acpi FeaturesDimensions Onboard I/O5000P Block Diagram of the 5000P ChipsetChipset Overview Xeon Dual Core ProcessorsXeon Quad Core Processors PC Health Monitoring Special FeaturesExternal Modem Ring-On Acpi FeaturesSlow Blinking LED for Suspend-State Indicator Main Switch Override MechanismSuper I/O Power SupplyPage Page Unpacking PrecautionsInstallation Static-Sensitive DevicesInstallation of the LGA771 Processor Processor and Heatsink InstallationPage Installation of the Heatsink To Un-install the HeatsinkCEK Heatsink Installation Mounting the Motherboard in the Chassis Dimm Module Population Configuration Installing DIMMsDimm Installation Memory SupportInstalling and Removing DIMMs Back Panel Connectors/IO Ports Control Panel Connectors/IO PortsJF1 Header Pins Power ButtonFront Control Panel NMI Button Pin Definitions JF1 Power LEDPower LED Pin Definitions JF1 Front Control Panel Pin Definitions NMI ButtonNIC1/NIC2 LED Indicators Pin# Definition 13 +5V HD ActivePin# Definition Vcc 10/12 Ground PWR Supply Fail Power Fail LEDOverheat/Fan Fail LED OH OH/Fan Fail LEDReset Button Pin Definitions JF1 Reset ButtonPower Button Reset Button B. PWR ButtonConnecting Cables ATX Power ConnectorProcessor Power Connector Front Panel USB Universal Serial Bus USBChassis Intrusion Backpanel USBFan Header Pin Definitions Fan1-8 Fan HeadersKeylock Fan Fan 7 CPU Fan Fan 8 CPU FanPin 10 is available on COM2 only. NC No Connection COM1 is a connector located onATX PS/2 Keyboard and PS/2 Mouse Ports Serial PortsWake-On-LAN Pin Definitions WOL Wake-On-RingWake-On-LAN Wake-On-Ring Pin Definitions WORPWR LED/Speaker Power LED/SpeakerSpeaker Connector Glan 1/2 Giga-bit Ethernet PortsAlarm Reset Power Fault PWR Supply FailureAlarm Reset Power Fault B. Alarm ResetPin# Definition Data Ground Clock No Connection SMBus PS I2C ConnectorSMB J18 PWR SMB J17 SMB Header Pin DefinitionsLocation VGA ConnectorSgpio Headers There are two T-SGPIO Serial GeneralCompact Flash PWR Compact Flash Card PWR ConnectorCompact Flash Card PWR Connector Jumper Definition Compact Flash Power On Off Power OffExplanation Jumpers Jumper SettingsGlan Enable/Disable Glan Port1 Enable B. Glan Port2 EnableCmos Clear Watch Dog Enable/DisableClear Cmos Watch Dog Enable Watch Dog Jumper Settings JWD3rd PWR Supply PWR Fault Jumper Settings 3rd PWR Supply PWR Fault Detect J3PVGA Enable/Disable 3rd PWR Fail B. VGA EnabledJ27 Compact Flash Master/Slave SelectI2C Bus to PCI-X/PCI-Exp. Slots Compact Flash Master/ Slave SelectRear View Onboard IndicatorsOnboard Power LED Glan LEDsOH/Fan Fail LED Overheat LED/Fan Fail JOH1Overheat LED Overheat LED Pin DefinitionsOn the IO panel. See the table on ConnectorParallel Printer Port Parallel printer port is LocatedFloppy Connector Simlp SlotFloppy Simlp Compact Flash Card Slot IDE ConnectorsLosing the System’s Setup Configuration Troubleshooting ProceduresBefore Power On No PowerMemory Errors Technical Support ProceduresTroubleshooting System first boots up System configuration Frequently Asked QuestionsReturning Merchandise for Service Bios System BiosHow To Change the Configuration Data Starting the Setup UtilityRunning Setup Main Bios SetupPress the Delete key to enter Setup Main Bios Setup Menu IDE Channel 0 Master/Slave and IDE Secondary Master/Slave LBA Mode ControlTransfer Mode Ultra DMA ModeSata Ahci Available when Sata RAID is disabled Sata Controller ModeSerial ATA Sata RAID Enable ICH RAID Code Base Available when Sata RAID is enabledAdvanced Setup Resume On Modem Ring Power Loss ControlMemory Cache Cache System Bios Area Cache Video Bios AreaPCI Configuration Cache Base 512K-640KCache Extended Memory Discrete Mtrr AllocationReset Configuration Data Default Primary Video AdapterEmulated IRQ Solutions PCI Parity Error ForwardingEnable Master Latency TimerLarge Disk Access Mode 4GB PCI Hole Granularity Serr Signal ConditionMemory Branch Mode Advanced Chipset ControlAMB Thermal Sensor High Temperature Dram OperationCrystal Beach Features Clock Spectrum FeatureLegacy USB Support USB FunctionThermal Management 2 Available when supported by the CPU Frequency Ratio Available when supported by the CPUCore-Multi-Processing Available when supported by the CPU Machine Checking Available when supported by the CPUIntel Eist Support Available when supported by the CPU Hardware Prefetch Available when supported by the CPUDirect Cache Access Available when supported by the CPU DCA Delay Clocks Available when supported by the CPUBase I/O Address I/O Device ConfigurationKBC Clock Input Serial Port aEvent Log Validity DMA ChannelFloppy Disk Controller DMI Event LoggingConsole Type Console RedirectionCOM Port Address Baud RateCPU Overheat Alarm Peci Agent 1/2 Temperatures/System TemperatureHardware Monitoring Voltage Monitoring System TemperatureFan1-Fan8 Speeds Fan Speed Control ModesClear System Event Logging Bios Post ErrorsBios Post Watch Dog System Event LoggingTime Out Option OS Boot Watch DogTimer for Loading OS Minutes System Event Log/System Event Log List ModeIPMI LAN Configuration Realtime Sensor DataIP Address Source Default GatewayUpdate LAN Settings Vlan TaggingSecurity Settings Boot Priority Order/Excluded from Boot Orders Boot SettingsExit Page Description Bios Error Beep CodesError Message Beep CodeX7SBi+ User’s Manual Appendix B Installing the Windows OS Page Installing Other Drivers Appendix C Installing Other Software Programs and DriversDriver/Tool Installation Display Screen Configuring Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control