SUPER MICRO Computer AOCS2308LL8E user manual Other Configuration Tasks, Viewing Volume Properties

Page 77

Chapter 7: Integrated Mirroring and Integrated Mirroring Enhanced

If SATA disks are used for the IM/IME volume(s), the hot spare disk must also be a SATA disk. If SAS disks are used, the hot spare disk must also be a SAS disk. An error message appears if the selected disk is not the same type as the disks used in the IM/IME volumes.

5.[Optional] Select a second hot spare disk.

6.Select SAVE CHANGES then exit this menu to commit the changes.

The configuration utility pauses while the global hot spares are being added.

Follow these steps to delete a global hot spare:

1.Select MANAGE HOT SPARE on the MANAGE ARRAY screen (Figure 7-8).

2.Select DELETE HOT SPARE and then press C.

If there are two hot spares, select which one you want to delete.

3.Select SAVE CHANGES then exit this menu to commit the changes.

The configuration utility pauses while the global hot spare is being removed.

7-9 Other Configuration Tasks

This section explains how to perform other configuration and maintenance tasks for IM and IME volumes.

Viewing Volume Properties

Follow these steps to view the properties of volumes:

1.In the SAS BIOS CU, select an adapter from the ADAPTER LIST. Select the RAID PROPERTIES option.

The properties of the current volume are displayed. If global hot spares are defined, they are also listed.

NOTE: If you create one volume using SAS disks, another volume using SATA disks, and global hot spare disks, the hot spare disks will only appear when you view the volume that has the same type of disks as the hot spare disks.

2.If two volumes are configured, press ALT+N to view the other array.

3.To manage the current array, select MANAGE ARRAY and press ENTER.

Synchronizing an Array

The Synchronize Array command forces the firmware to resynchronize the mirrored disks data in the array. It is seldom necessary to use this command, because the firmware automatically keeps the mirrored data synchronized during normal operation. When you use this command, one disk of the array is placed in the Degraded state until the data on the mirrored disks has been resynchronized.

7-13

Image 77
Contents AOC-USAS-L8i Add-on Card User’s Manual AOC-USAS-L8i Add-on Card User’s Manual Table of Contents MegaRAID Window and Menus MegaRAID Overview and InstallationActivating an Array Integrated Mirroring and Integrated MirroringHardware and Software Requirements Using the Cfggen IR Configuration UtilityPreface Product FeaturesAbout this Manual Operating Systems SupportedHeadquarters Contacting SuperMicroGeneral Safety Guidelines Chapter Safety GuidelinesESD Safety Guidelines AOC-USAS-L8i Add-on Card User’s Manual Front Connectors and Pin Definitions Chapter Connectors, Jumpers and IndicatorsActive LED Connector Internal SAS ConnectorsJumper Locations Front Jumper Locations and Pin DefinitionsJumper Jumper Settings LED IndicatorsLNP7 RAID Minimum Drive RequirementsAOC-USAS-L8i Add-on Card User’s Manual RAID Modes Chapter RAID Modes, Firmware and DriversFlashing Firmware Downloading RAID Mode DriversGetting Firmware Downloads Activating RAID Modes in Oprom Bios AOC-USAS-L8i Add-on Card User’s Manual Configuring Arrays and Logical Drives Chapter MegaRAID Bios Configuration UtilityPerforming a Quick Configuration Using Easy Configuration Starting the MegaRAID Bios CUMegaRAID Bios Configuration Utility Using New Configuration and View/Add Configuration MegaRAID Bios Configuration Utility Initializing Virtual Drives Creating a Global Hotspare DriveFirst Initialization Method Virtual Drives List Screen Setting the Hard Disk Write Cache and Read Ahead PoliciesRebuilding a Drive Rebuilding a DriveHot Plug Support Initialization of Array Not Complete! Press ESC Checking Data ConsistencyViewing and Changing Adapter Properties Viewing and Changing Device PropertiesViewing Physical Drive Properties Forcing Drives Online or OfflineViewing and Changing Virtual Drive Properties Deleting a Virtual Drive Configuring a Bootable Virtual DriveClearing a Storage Configuration To clear a storage configuration, follow these steps AOC-USAS-L8i Add-on Card User’s Manual Creating Storage Configurations Chapter MegaRAID Overview and InstallationMaintaining Storage Configurations OverviewHardware and Software Requirements Installing for WindowsMegaRAID Overview and Installation Setup Type Screen Linux Error Messages Installing for LinuxExiting installation Starting MegaRAID Storage Manager Software Chapter MegaRAID Window and MenusSelect Server Window MegaRAID Window and Menus Physical/Logical View Panel MegaRAID Storage Manager WindowMenu Bar Properties/Operations/Graphical View PanelEvent Log Panel File Menu Creating a New Storage ConfigurationMode Selection Screen Understanding Virtual Disk Parameters Using Auto ConfigurationAuto Configuration Screen First Guided Configuration Screen Using Guided ConfigurationMegaRAID Window and Menus Second Guided Configuration Screen Manual Configuration First Manual Configuration Screen Using Manual Configuration RAIDDefining a Virtual Disk Screen Using Manual Configuration RAID Using Manual Configuration RAID Using Manual Configuration RAID 10. Adding a Hotspare Disk Adding or Deleting a Hotspare DisksChanging Adjustable Task Rates Deleting a Virtual Disk Changing Virtual Disk PropertiesClearing a Storage Configuration from a Controller Saving a Storage Configuration to DiskAdding a Saved Storage Configuration Introduction IM/IME Description IM and IME FeaturesLogical View Resynchronization with Concurrent Host I/O Operation Integrated RAID FirmwareMetadata Support Hot SwappingHot Spare Disk Smart SupportMedia Verification Disk Write CachingFusion-MPT Support IM/IME Configuration OverviewCreating IM and IME Volumes Adapter List Screen Creating an IM VolumeAdapter Properties Screen Select New Array Type Screen Create New Array Screen Creating a Second IM or IME Volume Creating an IME VolumeManage Array Screen Managing Hot SparesSynchronizing an Array Other Configuration TasksViewing Volume Properties Deleting an Array Activating an ArraySelecting a Boot Disk Locating Drives in a VolumeAOC-USAS-L8i Add-on Card User’s Manual Chapter Integrated Striping Is FeaturesLSI Is DescriptionIntegrated Striping Firmware Is Configuration OverviewCreating is Volumes Creating is Volumes Create New Array Screen Viewing is Volume Properties Creating a Second is VolumeLocating a Disk in a Volume Selecting a Boot Disk AOC-USAS-L8i Add-on Card User’s Manual Chapter Using the Cfggen IR Configuration Utility Cfggen Interface Description Cfggen CommandsCreate Command Common Command Line ParametersCommand Line Display Command Defaults CommandSample Output Maxtor Format Command Status Command Hotspare CommandSetoffline Command Auto Command EFI Version Only Setonline CommandCfggen controller # auto volume type size qsync noprompt Enableir Command EFI Version Only Disableir Command EFI Version OnlyList Command EFI Version Only Disclaimer 10-2

AOCS2308LL8E specifications

Supermicro, a renowned leader in high-performance computing solutions, has introduced the AOC-S2308LL8E, a powerful SAS (Serial Attached SCSI) controller card designed to enhance storage performance and capability in enterprise systems. This cutting-edge controller provides exceptional functionality for organizations looking to handle large volumes of data efficiently.

The AOC-S2308LL8E features the LSI SAS2308 dual-core processor, which supports 12Gb/s data transfer rates, ensuring swift and reliable connections to storage devices. With its eight internal SAS/SATA ports, this controller card facilitates the connection of multiple drives, allowing for increased data throughput and redundancy, which are essential for critical applications such as database management and virtualization.

One of the standout characteristics of the AOC-S2308LL8E is its compatibility with both SAS and SATA drives. This flexibility allows organizations to choose between high-performance SAS drives or more economical SATA drives based on their specific storage requirements. The controller supports a wide array of RAID levels, including RAID 0, 1, 5, 6, 10, 50, and 60, providing users with the ability to select configurations that enhance data integrity and availability.

Additionally, the card is designed with an advanced cache memory that optimizes data access times, further enhancing overall performance. The AOC-S2308LL8E also features a low-profile form factor, making it suitable for various server chassis configurations, even in space-constrained environments.

In terms of connectivity, the AOC-S2308LL8E is equipped with dual mini-SAS connectors, enabling seamless connectivity to multiple storage devices. With support for a high number of simultaneous I/O operations, this controller card is well-suited for tasks requiring substantial bandwidth, like large-scale data processing and analytics.

Moreover, Supermicro's AOC-S2308LL8E comes with robust management and monitoring features, ensuring that users can maintain optimal performance levels while responding proactively to any potential issues. Built-in support for advanced error recovery techniques helps guarantee data integrity, a feature critical in any enterprise setting.

To summarize, the Supermicro AOC-S2308LL8E is an ideal solution for businesses looking to enhance their storage capabilities. With its combination of high data transfer rates, RAID support, compatibility with various storage drive types, and advanced management features, the AOC-S2308LL8E stands out as a reliable choice for maximizing performance in demanding environments. Organizations investing in this controller will benefit from its efficiency, reliability, and scalability, crucial for future-proofing their IT infrastructure.