Integrated Striping

This chapter provides an overview of the LSI Integrated Striping™ (IS) feature and explains how to create Integrated Striping (IS) volumes using the SAS BIOS Configuration Utility (SAS BIOS CU), which is used to setup IR Mode.

8-1 Introduction

The Integrated Striping (IS) feature is used for applications that require the faster performance and increased storage capacity of striping. The low-cost IS feature has many of the advantages of a more expensive RAID striping solution. A single IS logical drive may be configured as the boot disk or as a data disk.

The IS feature is implemented with controller firmware that supports the Fusion-MPT Interface. IS provides better performance and more capacity than individual disks, without burdening the host CPU. The firmware splits host I/Os over multiple disks and presents the disks as a single logical drive. In general, striping is transparent to the BIOS, the drivers, and the operating system.

The SAS BIOS CU is used to configure IS volumes, which can consist of two to ten disks.

8-2 IS Features

Integrated Striping supports the following features:

Support for volumes with two to ten disks

Support for two IS volumes (or one IS volume and one IM/IME volume) on a controller, with up to 12 disks total. (Requires Integrated RAID firmware v1.20.00 or above.)

NOTE: All physical disks in a volume must be connected to the same SAS controller.

Presents a single virtual drive to the OS for each configured volume

Support for both SAS and SATA drives, although the two types of drives cannot be combined in one volume

Fusion-MPT architecture

Easy-to-use SAS BIOS configuration utility

Error notification

Use of metadata to store volume configuration on disks

OS-specific event log

Error display inside the Fusion-MPT BIOS

8-1

Image 81
Contents AOC-USAS-L8i Add-on Card User’s Manual AOC-USAS-L8i Add-on Card User’s Manual Table of Contents MegaRAID Window and Menus MegaRAID Overview and InstallationActivating an Array Integrated Mirroring and Integrated MirroringHardware and Software Requirements Using the Cfggen IR Configuration UtilityPreface Product FeaturesAbout this Manual Operating Systems SupportedHeadquarters Contacting SuperMicroChapter Safety Guidelines ESD Safety GuidelinesGeneral Safety Guidelines AOC-USAS-L8i Add-on Card User’s Manual Front Connectors and Pin Definitions Chapter Connectors, Jumpers and IndicatorsActive LED Connector Internal SAS ConnectorsJumper Locations Front Jumper Locations and Pin DefinitionsJumper Jumper Settings LED IndicatorsLNP7 RAID Minimum Drive RequirementsAOC-USAS-L8i Add-on Card User’s Manual RAID Modes Chapter RAID Modes, Firmware and DriversDownloading RAID Mode Drivers Getting Firmware DownloadsFlashing Firmware Activating RAID Modes in Oprom Bios AOC-USAS-L8i Add-on Card User’s Manual Chapter MegaRAID Bios Configuration Utility Performing a Quick ConfigurationConfiguring Arrays and Logical Drives Using Easy Configuration Starting the MegaRAID Bios CUMegaRAID Bios Configuration Utility Using New Configuration and View/Add Configuration MegaRAID Bios Configuration Utility Initializing Virtual Drives Creating a Global Hotspare DriveFirst Initialization Method Virtual Drives List Screen Setting the Hard Disk Write Cache and Read Ahead PoliciesRebuilding a Drive Rebuilding a DriveHot Plug Support Initialization of Array Not Complete! Press ESC Checking Data ConsistencyViewing and Changing Adapter Properties Viewing and Changing Device PropertiesForcing Drives Online or Offline Viewing and Changing Virtual Drive PropertiesViewing Physical Drive Properties Configuring a Bootable Virtual Drive Clearing a Storage ConfigurationDeleting a Virtual Drive To clear a storage configuration, follow these steps AOC-USAS-L8i Add-on Card User’s Manual Creating Storage Configurations Chapter MegaRAID Overview and InstallationMaintaining Storage Configurations OverviewHardware and Software Requirements Installing for WindowsMegaRAID Overview and Installation Setup Type Screen Linux Error Messages Installing for LinuxExiting installation Starting MegaRAID Storage Manager Software Chapter MegaRAID Window and MenusSelect Server Window MegaRAID Window and Menus Physical/Logical View Panel MegaRAID Storage Manager WindowProperties/Operations/Graphical View Panel Event Log PanelMenu Bar File Menu Creating a New Storage ConfigurationMode Selection Screen Understanding Virtual Disk Parameters Using Auto ConfigurationAuto Configuration Screen First Guided Configuration Screen Using Guided ConfigurationMegaRAID Window and Menus Second Guided Configuration Screen Manual Configuration First Manual Configuration Screen Using Manual Configuration RAIDDefining a Virtual Disk Screen Using Manual Configuration RAID Using Manual Configuration RAID Using Manual Configuration RAID 10. Adding a Hotspare Disk Adding or Deleting a Hotspare DisksChanging Adjustable Task Rates Deleting a Virtual Disk Changing Virtual Disk PropertiesClearing a Storage Configuration from a Controller Saving a Storage Configuration to DiskAdding a Saved Storage Configuration Introduction IM/IME Description IM and IME FeaturesLogical View Resynchronization with Concurrent Host I/O Operation Integrated RAID FirmwareMetadata Support Hot SwappingHot Spare Disk Smart SupportMedia Verification Disk Write CachingIM/IME Configuration Overview Creating IM and IME VolumesFusion-MPT Support Adapter List Screen Creating an IM VolumeAdapter Properties Screen Select New Array Type Screen Create New Array Screen Creating a Second IM or IME Volume Creating an IME VolumeManage Array Screen Managing Hot SparesOther Configuration Tasks Viewing Volume PropertiesSynchronizing an Array Deleting an Array Activating an ArraySelecting a Boot Disk Locating Drives in a VolumeAOC-USAS-L8i Add-on Card User’s Manual Chapter Integrated Striping Is FeaturesLSI Is DescriptionIntegrated Striping Firmware Is Configuration OverviewCreating is Volumes Creating is Volumes Create New Array Screen Viewing is Volume Properties Creating a Second is VolumeLocating a Disk in a Volume Selecting a Boot Disk AOC-USAS-L8i Add-on Card User’s Manual Chapter Using the Cfggen IR Configuration Utility Cfggen Interface Description Cfggen CommandsCreate Command Common Command Line ParametersCommand Line Display Command Defaults CommandSample Output Maxtor Format Command Status Command Hotspare CommandSetoffline Command Auto Command EFI Version Only Setonline CommandCfggen controller # auto volume type size qsync noprompt Enableir Command EFI Version Only Disableir Command EFI Version OnlyList Command EFI Version Only Disclaimer 10-2

AOCS2308LL8E specifications

Supermicro, a renowned leader in high-performance computing solutions, has introduced the AOC-S2308LL8E, a powerful SAS (Serial Attached SCSI) controller card designed to enhance storage performance and capability in enterprise systems. This cutting-edge controller provides exceptional functionality for organizations looking to handle large volumes of data efficiently.

The AOC-S2308LL8E features the LSI SAS2308 dual-core processor, which supports 12Gb/s data transfer rates, ensuring swift and reliable connections to storage devices. With its eight internal SAS/SATA ports, this controller card facilitates the connection of multiple drives, allowing for increased data throughput and redundancy, which are essential for critical applications such as database management and virtualization.

One of the standout characteristics of the AOC-S2308LL8E is its compatibility with both SAS and SATA drives. This flexibility allows organizations to choose between high-performance SAS drives or more economical SATA drives based on their specific storage requirements. The controller supports a wide array of RAID levels, including RAID 0, 1, 5, 6, 10, 50, and 60, providing users with the ability to select configurations that enhance data integrity and availability.

Additionally, the card is designed with an advanced cache memory that optimizes data access times, further enhancing overall performance. The AOC-S2308LL8E also features a low-profile form factor, making it suitable for various server chassis configurations, even in space-constrained environments.

In terms of connectivity, the AOC-S2308LL8E is equipped with dual mini-SAS connectors, enabling seamless connectivity to multiple storage devices. With support for a high number of simultaneous I/O operations, this controller card is well-suited for tasks requiring substantial bandwidth, like large-scale data processing and analytics.

Moreover, Supermicro's AOC-S2308LL8E comes with robust management and monitoring features, ensuring that users can maintain optimal performance levels while responding proactively to any potential issues. Built-in support for advanced error recovery techniques helps guarantee data integrity, a feature critical in any enterprise setting.

To summarize, the Supermicro AOC-S2308LL8E is an ideal solution for businesses looking to enhance their storage capabilities. With its combination of high data transfer rates, RAID support, compatibility with various storage drive types, and advanced management features, the AOC-S2308LL8E stands out as a reliable choice for maximizing performance in demanding environments. Organizations investing in this controller will benefit from its efficiency, reliability, and scalability, crucial for future-proofing their IT infrastructure.