5. Cable Hook-up

CAUTION! Loose connectors result in excessive voltage drop and may cause overheated wires and melted insulation.

CAUTION! Reverse polarity connection (positive to negative) will blow the fuses in the Sima STP-3000 and may permanently damage the inverter. Damage caused by reverse polarity connection is not covered by your warranty.

WARNING! Spark may be observed when connection is first made as current starts to charge up capacitors in the Sima STP-3000. Do not make this connection in the presence of flammable fumes. Explosion or fire may result.

Cables connecting the inverter to the DC power source must be as short as possible and sufficiently large for the required current flow so as to minimize the voltage drop and to maintain high efficiency of the overall system.

Sima’s STP-3000 comes with a basic wiring kit to permanently install your inverter to a single battery. Multiple battery installation like the examples that follow in our manual require additional cables and connectors that are not supplied and have to be purchased before installation.

The supplied cables come with pre-installed ring terminals for connection from the STP-3000 to your battery. The cable kit includes the following items.

1.1pc RED (+ POS) wire (80mm^2) 1.0 meter in length

2.1pc RED (+ POS) wire (80mm^2) 0.5 meter in length

3.1pc BLACK (- NEG) wire (80mm^2) 1.5 meters in length

4.1pc GREEN (- ground) wire.

5.Fuse block assembly

6.2 pieces 250 Amp fuses

NOTE: Installation requires an open workspace free from obstructions or obstacles. Wear proper eye protection. If you are not qualified to install high power devices or if you are unsure of the proper safety precautions needed to install a high power device like the STP-3000 then STOP RIGHT HERE! CONTACT A LOCAL INSTALLATION EXPERT TO INSTALL YOUR INVERTER.

Mounting the inverter and fuse block assembly:

1.Make sure the inverter is turned off. Select an inverter location that is free from water and combustible fumes. You will need to purchase the necessary hardware bolts/nuts, screws…etc for your particular installation.

2.Select fuse block location. Location must be less than 0.5 meters from battery and less than 1.0 meters from the inverter. Assemble fuse block assembly with supplied bolts/nuts. Make sure you install and secure the fuse. Mount fuse block with supplied sheet metal screws to

your chosen location.

Connecting the wires – refer to Fig. 4 at right:

3.

Connect one end of the supplied GREEN wire to the Earth Ground

 

 

connection on the DC side of the inverter.

 

4.

Connect the other end of the GREEN wire to a secure location on

 

 

vehicle chassis.

 

5.

Connect one end of the BLACK wire to the – NEG connection on

 

 

your battery. Most MARINE type batteries have a STUD type mount

 

 

in addition to a CLAMP type mount that can be used with the ring

 

 

terminal. If your battery only has the CLAMP type connections you

 

 

will need to purchase an adapter from your local auto parts or

 

 

battery supply store to use the supplied cables. Secure with

 

 

supplied lock washer and nut that came with your battery or adapter.

 

6.

Connect the other end of the BLACK wire to the – NEG connection

 

 

on the inverter. Secure with supplied lock washer and nut.

 

7.

Connect one end of the shorter 0.5 meter RED wire to the end of

 

 

the supplied fuse block that is closest to your battery. Secure with

Fig. 4

 

supplied lock washer and nut

8.Connect the other end of the shorter 0.5 meter RED wire to the + POS connection on your battery. Most MARINE type batteries have

a STUD type mount in addition to a CLAMP type mount that can be used with the ring terminal. If your battery only has the CLAMP type connections you will need to purchase an adapter from your local auto parts or battery supply store to use the supplied cables Secure with supplied lock washer and nut that came with your battery or adapter.

NOTE: Steps 9 & 10 are your final connections to supply power to your inverter. Making this connection will create a spark. Make sure the last connection is to the supplied fuse block. Make sure the inverter is turned off before you continue. Make sure you are wearing adequate eye protection.

9.Connect one end of the longer 1.0 meter RED wire to the + POS connection on the inverter. Secure with supplied lock washer and nut.

10.This connection will create a spark: Connect the other end of the longer 1.0 meter RED wire to the end of the supplied fuse block that is closest to the inverter. Secure with supplied lock washer and nut.

Safe operation of the Sima STP-3000 requires a solid, low resistance connection to the DC power

source.

Page 6 of 14

Image 6
Contents 12V DC Power Inverter Physical Layout of the Sima STP-3000 Permanent Installation Introduction Sima STP-3000 Output WaveformPhysical Layout of the Sima STP-3000 AC PanelBattery Permanent InstallationWhere to Install Battery typeMounting the inverter and fuse block assembly Connecting the wires refer to at rightCable Hook-up Sima STP-3000 AC Wiring ConnectionsBattery Cables if cable installation kit is not included Code, PartGround Wiring Front Panel Controls and IndicatorsOperation Accessories TroubleshootingVolt Battery Sizing Chart for reference only Appendix a Battery SizingTroubleshooting Guide Problem and symptoms Possible Cause SolutionAppendix B Connection to Multiple Batteries Product Dimensions Limited WarrantySpecifications Electrical PerformancePage Sima STP-3000~12V Rev 1.0 PN21714